SD5800

ifm electronic gmbh SD5800

industrial gas counter, SDR14DGXFRKG/US-100

  • Бренд: ifm electronic gmbh
  • Артикул (MPN): SD5800
  • Статус производства: Не определён

Категории:

Технические характеристики

Number of inputs and outputsNumber of digital outputs: 2; Number of analog outputs: 1
Measuring range-10...60 °C: 14...140 °F
Process connectionthreaded connection G 1/4 Internal thread DN8
Applicationfor industrial applications
Mediahelium
Medium temperature [°C]-10...60
Min. burst pressure [bar]64
Pressure rating16 bar: 1.6 MPa
MAWP (for applications according to CRN) [bar]9.5
Напряжение питания18...30 DC; (to SELV/PELV)
Current consumption [mA]< 80
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]1
Inputscounter reset
Output signalswitching signal; analog signal; pulse signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / closed; (configurable)
Напряжение питания2.5
Permanent current rating of switching output DC [mA]150; (per output)
Number of analog outputs1
Analog current output [mA]4...20; (scalable)
Max. load [Ω]500
Pulse outputconsumed quantity meter
Short-circuit protectionyes
Type of short-circuit protectionyes (non-latching)
Overload protectionyes
Display range-24...74 °C: -11.2...165.2 °F
Resolution0.2 °C: 0.5 °F
Set point SP-9.7...60 °C: 14.6...140 °F
Reset point rP-10...59.7 °C: 14...139.4 °F
Analog start point ASP0...66.6 l/min: 0...22.1 m/s: 0...4 m³/h
Analog end point AEP16.7...83.3 l/min: 5.5...27.6 m/s: 1...5 m³/h
Low flow cut-off LFC0.6...0.8 l/min: 0.2...0.3 m/s: 0.04...0.05 m³/h
In steps of0.1 °C: 0.1 °F
Measuring range [bar]-1...16
Display range [bar]-1...20
Resolution [bar]0.05
Set point SP [bar]-0.92...16
Reset point rP [bar]-1...15.92
Analog start point [bar]-1...12.8
Analog end point [bar]2.2...16
In steps of [bar]0.01
Pulse value0.001...10000000 m³: 0.05...353146667.2 scf
Pulse length [s]0.01...2
Analog start point-10...46 °C: 14...114.8 °F
Analog end point4...60 °C: 39.2...140 °F
Temperature coefficient [1/K]± 0,07 % MW
Accuracy (in the measuring range)± (6 % MW + 0,6 % MEW); at medium temperature 23 °C
Repeatability0,8 % MW + 0,2 % MEW
Repeatability [% of the final value]± 0,2
Characteristics deviation [% of the final value]< ± 0,5; (BFSL = Best Fit Straight Line)
Greatest TEMPCO of the span [% MEW / 10 K]± 0,15
Greatest TEMPCO of the zero point [% MEW / 10 K]± 0,25
Accuracy [K]± 0,5; (medium flow in the limit area of the flow measurement range)
Время отклика0.05
Damping process value dAP [s]0...5
Dynamic response T05 / T09 [s]T09 = 0,5
Parameter setting optionshysteresis / window; normally open / closed; current/pulse output; display can be rotated and switched off; Display unit; totalizer
Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9 CDV
ProfilesCommon - I&D: Identification and Diagnosis; Function: Measurement data, standard resolution
SIO modeyes
Required master port classA
Process data analog8
Process data binary2
Min. process cycle time [ms]7.2
Supported DeviceIDsType of operation: DeviceID; default: 1301
Рабочая температура0...60
Storage temperature [°C]-20...85
Max. relative air humidity [%]90
ProtectionIP 65; IP 67
EMCDIN EN 60947-5-9
CPA approvalmodel number: 003TG; accuracy class: -; maximum allowable error: ± 7 % FS; Q (min): 0,05 m³/h (He); Q (t): -; Q (max): 5 m³/h (He)
Vibration resistanceDIN EN 68000-2-6: 5 g (10...2000 Hz)
MTTF [years]180
UL approvalUL approval number: I012; File number UL: E174189
Pressure equipment directivesound engineering practice; can be used for stable gases fluid group 2
Масса554
Housingrectangular
Dimensions [mm]182 x 45.4 x 67.8
МатериалPBT+PC-GF30; PPS GF40; stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); steel (1.5523) galvanized; 2.0401 (brass / CW614N); FKM
МатериалEN AW-6082 (aluminium); stainless steel (1.4305 / 303); FKM; ceramics glass passivated; PPS GF40; Al2O3 (ceramics); acrylate
DisplayColor display 1,44", 128 x 128 pixels; 2 x LED, yellow
RemarksMW = Measured value; MEW = Final value of the measuring range; Standard conditions: 1013.25 mbar / 15 °C / 0 % relative humidity; For information about installation and operation please see the operating instructions.
Pack quantity1 pcs.
Connector1 x M12; coding: A; Contacts: 4
Получить предложение по этой позиции