ifm electronic gmbh SDG350
Compressed air meter, SDG2 1/2"METRIS PB DN65 SS
Категории:
Технические характеристики
| Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
|---|---|
| Measuring range | -10...60 °C: 14...140 °F |
| Process connection | flange DN65 according to:DIN EN 10220 |
| Application | for industrial applications |
| Media | compressed air |
| Medium temperature [°C] | -10...60 |
| Min. burst pressure | 64 bar: 6.4 MPa |
| Pressure rating | 16 bar: 1.6 MPa |
| Напряжение питания | 18...30 DC; (to SELV/PELV) |
| Current consumption [mA] | < 80 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | 1 |
| Inputs | counter reset |
| Output signal | switching signal; analog signal; pulse signal; IO-Link; (configurable) |
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / closed; (configurable) |
| Напряжение питания | 2.5 |
| Permanent current rating of switching output DC [mA] | 150; (per output) |
| Number of analog outputs | 1 |
| Analog current output [mA] | 4...20; (scalable) |
| Max. load [Ω] | 500 |
| Pulse output | consumed quantity meter |
| Short-circuit protection | yes |
| Type of short-circuit protection | yes (non-latching) |
| Overload protection | yes |
| Display range | -24...74 °C: -11.2...165.2 °F |
| In steps of | 0.1 °C: 0.1 °F |
| Measuring range [bar] | -1...16 |
| Display range [bar] | -1...20 |
| Resolution [bar] | 0.05 |
| Set point SP [bar] | -0.92...16 |
| Reset point rP [bar] | -1...15.92 |
| Analog start point [bar] | -1...12.8 |
| Analog end point [bar] | 2.2...16 |
| In steps of [bar] | 0.01 |
| Set point SP | -9.7...60 °C: 14.6...140 °F |
| Pulse value | 0.001...10000000 m³: 0.05...353146667.2 scf |
| Pulse length [s] | 0.002...2 |
| Resolution | 0.2 °C: 0.5 °F |
| Reset point rP | -10...59.7 °C: 14...139.4 °F |
| Analog start point | -10...46 °C: 14...114.8 °F |
| Analog end point | 4...60 °C: 39.2...140 °F |
| Accuracy (in the measuring range) | class 141: ± (3 % MW + 0,3 % MEW); class 344: ± (6 % MW + 0,6 % MEW) ; air quality to ISO 8573-1:2010; reference conditions: inlet pipe length >= 113 cm outlet pipe length >= 15 cm; reference temperature: 18..26 °C; standard volume flow 8...1155 m³/h; (standard volume flow DIN_ISO_2533 15 °C , 1013,25 mbar, 0 % r.H.) |
| Repeatability [% of the final value] | ± 0,2 |
| Characteristics deviation [% of the final value] | < ± 0,5; (BFSL = Best Fit Straight Line) |
| Greatest TEMPCO of the span [% MEW / 10 K] | ± 0,3 |
| Greatest TEMPCO of the zero point [% MEW / 10 K] | ± 0,1 |
| Accuracy [K] | ± 0,5; (medium flow in the limit area of the flow measurement range) |
| Время отклика | 0.05 |
| Damping process value dAP [s] | 0...5 |
| Dynamic response T05 / T09 [s] | T09 = 0,5 |
| Parameter setting options | hysteresis / window; normally open / closed; current/pulse output; display can be rotated and switched off; Display unit; totalizer |
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 CDV |
| Profiles | Common - I&D: Identification and Diagnosis; Function: Measurement data, standard resolution |
| SIO mode | yes |
| Required master port class | A |
| Process data analog | 8 |
| Process data binary | 2 |
| Min. process cycle time [ms] | 7.2 |
| Supported DeviceIDs | Type of operation: DeviceID; default: 1537 |
| Рабочая температура | 0...60 |
| Storage temperature [°C] | -20...85 |
| Max. relative air humidity [%] | 90 |
| Protection | IP 65; IP 67 |
| EMC | DIN EN 60947-5-9 |
| Vibration resistance | DIN EN 68000-2-6: 5 g (10...2000 Hz) |
| MTTF [years] | 167 |
| Pressure equipment directive | Modul A; can be used for group 2 fluids; group 1 fluids on request |
| Масса | 9630 |
| Housing | rectangular |
| Dimensions [mm] | 148 x 125 x 186 |
| Материал | housing sensor: PBT+PC-GF30; PPS GF40; electronics fastener: stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); knurled nut: stainless steel (1.4404 / 316L); sealing-Display: FKM |
| Материал | sensor feedthrough: stainless steel (1.4301 / 304), stainless steel (1.4404 / 316L); Sealing sensor - Pipe section: FKM; sensor tip: ceramics glass passivated; PPS GF40; Al2O3 (ceramics); acrylate; Pipe section: stainless steel (1.4301 / 304); flange: stainless steel (1.4301 / 304) |
| Display | Color display 1,44", 128 x 128 pixels; 2 x LED, yellow |
| Remarks | MW = Measured value; MEW = Final value of the measuring range; D = inside pipe diameter; Measuring, display and setting ranges refer to standard volume flow according to DIN ISO 2533.; For information about installation and operation please see the operating instructions. |
| Pack quantity | 1 pcs. |
| Connector | 1 x M12; coding: A; Contacts: 4 |