ifm electronic gmbh SDP110
Gap distance sensor, SDR14DGXFRKG/US-100
Категории:
Технические характеристики
| Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
|---|---|
| Process connection | threaded connection G 1/4 Internal thread DN8 |
| Measuring range [µm] | 0...400; (depending on the nozzle used) |
| Application | for industrial applications |
| Media | compressed air |
| Medium temperature [°C] | -10...60 |
| Min. burst pressure | 64 bar: 6.4 MPa |
| Pressure rating | 16 bar: 1.6 MPa |
| MAWP (for applications according to CRN) | 16 bar: 1.6 MPa |
| Напряжение питания | 18...30 DC; (to SELV/PELV) |
| Current consumption [mA] | < 80 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | 1 |
| Inputs | teach input |
| Output signal | switching signal; analog signal; IO-Link; (configurable) |
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / closed; (configurable) |
| Напряжение питания | 2.5 |
| Permanent current rating of switching output DC [mA] | 150; (per output) |
| Number of analog outputs | 1 |
| Analog current output [mA] | 4...20; (scalable) |
| Max. load [Ω] | 500 |
| Short-circuit protection | yes |
| Type of short-circuit protection | yes (non-latching) |
| Overload protection | yes |
| Setting range [µm] | 0...500; (depending on the nozzle used) |
| Resolution [µm] | 1 |
| Set point SP [µm] | 2...500 |
| Reset point rP [µm] | 0...498 |
| Analog start point ASP [µm] | 0...400 |
| Analog end point AEP [µm] | 100...500 |
| In steps of [µm] | 1 |
| Measuring range | 0.8...100 l/min: 0.3...33.2 m/s: 0.05...6 m³/h |
| Setting range | 0...1000 |
| Resolution | 0.2 l/min: 0.1 m/s: 0.01 m³/h |
| Set point SP | 1.4...100 l/min: 0.5...33.2 m/s: 0.08...6 m³/h |
| Reset point rP | 0.9...99.5 l/min: 0.3...33 m/s: 0.05...5.97 m³/h |
| Analog start point ASP | 0...80 l/min: 0...26.6 m/s: 0...4.8 m³/h |
| Analog end point AEP | 20...100 l/min: 6.6...33.2 m/s: 1.2...6 m³/h |
| In steps of | 0.1 l/min: 0.1 m/s: 0.01 m³/h |
| Measuring range [bar] | -1...16 |
| Display range [bar] | -1...20 |
| Resolution [bar] | 0.05 |
| Set point SP [bar] | -0.92...16 |
| Reset point rP [bar] | -1...15.92 |
| Analog start point [bar] | -1...12.8 |
| Analog end point [bar] | 2.2...16 |
| In steps of [bar] | 0.01 |
| Display range | 0...120 l/min: 0...39.8 m/s: 0...7.2 m³/h |
| Low flow cut-off LFC | 0.6...1 l/min: 0.2...0.3 m/s: 0.04...0.06 m³/h |
| Accuracy (in the measuring range) | class 141: ± (2 % MW + 1 % MEW); class 344: ± (6 % MW + 1,2 % MEW) ; air quality to ISO 8573-1:2010; at medium temperature 23 °C |
| Repeatability | ± (0,8 % MW + 0,4 % MEW) |
| Repeatability [% of the final value] | ± 0,2 |
| Characteristics deviation [% of the final value] | < ± 0,5; (BFSL = Best Fit Straight Line) |
| Greatest TEMPCO of the span [% MEW / 10 K] | ± 0,3 |
| Greatest TEMPCO of the zero point [% MEW / 10 K] | ± 0,1 |
| Temperature coefficient [1/K] | ± 0,07 % MW |
| Время отклика | 0.1; (dAP = 0) |
| Damping process value dAP [s] | 0...5 |
| Parameter setting options | hysteresis / window; normally open / closed; current output; display can be rotated and switched off; Display unit; Teach function |
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Common - I&D: Identification and Diagnosis; Function: Measurement data, standard resolution |
| SIO mode | yes |
| Required master port class | A |
| Process data analog | 7 |
| Process data binary | 2 |
| Min. process cycle time [ms] | 5.9 |
| Supported DeviceIDs | Type of operation: DeviceID; default: 1333 |
| Note | For further information please see the IODD PDF file at "Downloads" |
| Рабочая температура | 0...60 |
| Storage temperature [°C] | -20...85 |
| Max. relative air humidity [%] | 90 |
| Protection | IP 65; IP 67 |
| EMC | DIN EN 60947-5-9 |
| Vibration resistance | DIN EN 68000-2-6: 5 g (10...2000 Hz) |
| MTTF [years] | 167 |
| UL approval | UL approval number: I012; File number UL: E174189 |
| Pressure equipment directive | sound engineering practice; can be used for stable gases fluid group 2 |
| Масса | 548.2 |
| Housing | rectangular |
| Dimensions [mm] | 182 x 45.4 x 67.8 |
| Материал | PBT+PC-GF30; PPS GF40; stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); steel (1.5523) galvanized; 2.0401 (brass / CW614N); FKM |
| Материал | EN AW-6082 (aluminium); stainless steel (1.4305 / 303); FKM; ceramics glass passivated; PPS GF40; Al2O3 (ceramics); acrylate; SINT-A51; stainless steel (1.4301 / 304); CW510L (brass) |
| Display | Color display 1,44", 128 x 128 pixels; 2 x LED, yellow |
| Remarks | MW = Measured value; MEW = Final value of the measuring range; Measuring, display and setting ranges refer to standard volume flow according to DIN ISO 2533.; For information about installation and operation please see the operating instructions. |
| Pack quantity | 1 pcs. |
| Connector | 1 x M12; coding: A; Contacts: 4 |