SM4100

ifm electronic gmbh SM4100

Magnetic-inductive flow meter, SMR14DXXFRKG/US-100

  • Бренд: ifm electronic gmbh
  • Артикул (MPN): SM4100
  • Статус производства: Не определён

Категории:

Технические характеристики

Number of inputs and outputsNumber of digital outputs: 2; Number of analog outputs: 1
Measuring range5...3000 ml/min: 0.005...3 l/min
Process connectionthreaded connection G 1/4 external thread DN6 flat seal
Special featuregold-plated contacts
ApplicationTotalizer function; for industrial applications
Installationconnection to pipe by means of an adapter
MediaConductive liquids; water; water-based media
Note on mediaconductivity: ≥ 20 µS/cm; viscosity: < 70 mm²/s (40 °C)
Medium temperature [°C]0...60
Pressure rating10 bar: 1 MPa
MAWP (for applications according to CRN)8.6 bar: 0.86 MPa
Напряжение питания18...30 DC; (to SELV/PELV)
Current consumption [mA]< 80
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]5
Measuring principlemagnetic-inductive
Inputscounter reset
Total number of outputs2
Output signalswitching signal; analog signal; pulse signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / closed; (configurable)
Напряжение питания2
Permanent current rating of switching output DC [mA]200
Number of analog outputs1
Analog current output [mA]4...20; (scalable)
Max. load [Ω]500
Напряжение питания0...10; (scalable)
Min. load resistance [Ω]2000
Pulse outputflow rate meter
Short-circuit protectionyes
Type of short-circuit protectionyes (non-latching)
Overload protectionyes
Display range [ml/min]-1999...3600
Resolution [ml/min]1
Set point SP [ml/min]20...3000
Reset point rP [ml/min]5...2984
Analog start point ASP [ml/min]0...2400
Analog end point AEP [ml/min]600...3000
Low flow cut-off LFC [ml/min]< 60
Pulse value1...3000 ml
Pulse length [s]0,008...2
Measuring range [°C]-20...80
Resolution [°C]0.2
Set point SP [°C]-19.2...80
Reset point rP [°C]-19.6...79.6
Analog start point [°C]-20...60
Analog end point [°C]0...80
In steps of [°C]0.2
Accuracy (in the measuring range)± (2 % MW + 0,5 % MEW)
Repeatability± 0,2 % MEW
Accuracy [K]± 2,5 (Q > 0,5 l/min)
Время отклика0.15; (dAP = 0, T19)
Delay time programmable dS, dr [s]0...50
Damping process value dAP [s]0...5
Dynamic response T05 / T09 [s]T09 = 40 (Q > 1 l/min)
Parameter setting optionsFlow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / closed; switching logic; current/voltage/pulse output; Start-up delay; display can be deactivated; Display unit
Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
ProfilesSmart Sensor - SSP 0: Generic Profiled Sensor; Function: Device identification; Function: Process data variable; Function: Device diagnosis
SIO modeyes
Required master port classA
Process data analog3
Process data binary2
Min. process cycle time [ms]5
Supported DeviceIDsType of operation: DeviceID; default: 671
Рабочая температура-10...60
Storage temperature [°C]-25...80
ProtectionIP 67
EMCDIN EN 60947-5-9
CPA approvalmodel number: 007MI; accuracy class: -; maximum allowable error: ± 2,5 % FS; Q (min): 0,0003 m³/h; Q (t): -; Q (max): 0,18 m³/h
Shock resistanceDIN IEC 68-2-27: 20 g (11 ms)
Vibration resistanceDIN IEC 68-2-6: 5 g (10...2000 Hz)
MTTF [years]144
Pressure equipment directivesound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Масса537
Inlet pipe length3 x DN
Outlet pipe length1 x DN
Dimensions [mm]Ø 54 / L = 110
Материалstainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE
Материалstainless steel (1.4404 / 316L); PEEK; EPDM
DisplayDisplay unit: 6 x LED, green (ml/min, l/h, l, m³, °C, 10³); Switching status: 2 x LED, yellow; Measured values: alphanumeric display, 4-digit; Programming: alphanumeric display, 4-digit
RemarksMW = Measured value; MEW = Final value of the measuring range
Pack quantity1 pcs.
Connector1 x M12; coding: A; Contacts: 4, gold-plated
Получить предложение по этой позиции