SM7001

ifm electronic gmbh SM7001

Magnetic-inductive flow meter, SMR34GGXFRKG/US-100

  • Бренд: ifm electronic gmbh
  • Артикул (MPN): SM7001
  • Статус производства: Не определён

Категории:

Технические характеристики

Number of inputs and outputsNumber of digital outputs: 2; Number of analog outputs: 1
Measuring range3...792 gph: 0.06...13.2 gpm
Process connectionthreaded connection G 3/4 external thread DN20 flat seal
Special featuregold-plated contacts
ApplicationTotalizer function; for industrial applications
Installationconnection to pipe by means of an adapter
MediaConductive liquids; water; water-based media
Note on mediaconductivity: ≥ 20 µS/cm; viscosity: < 70 mm²/s (40 °C)
Medium temperature [°F]14...158
Pressure rating16 bar: 232 psi: 1.6 MPa
MAWP (for applications according to CRN)10.4 bar: 1.04 MPa
Напряжение питания18...30 DC; (to SELV/PELV)
Current consumption [mA]95; (24 V)
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]5
Measuring principlemagnetic-inductive
Inputscounter reset
Total number of outputs2
Output signalswitching signal; analog signal; pulse signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / closed; (configurable)
Напряжение питания2
Permanent current rating of switching output DC [mA]200
Number of analog outputs1
Analog current output [mA]4...20; (scalable)
Max. load [Ω]500
Напряжение питания0...10; (scalable)
Min. load resistance [Ω]2000
Pulse outputflow rate meter
Short-circuit protectionyes
Type of short-circuit protectionyes (non-latching)
Overload protectionyes
Display range-951...951 gph: -15.84...15.84 gpm
Resolution1 gph: 0.02 gpm
Set point SP7...792 gph: 0.12...13.2 gpm
Reset point rP3...788 gph: 0.06...13.14 gpm
Analog start point ASP0...636 gph: 0...10.6 gpm
Analog end point AEP156...792 gph: 2.6...13.2 gpm
In steps of1 gph: 0.02 gpm
Pulse value0.01...99 990 000 gal
Pulse length [s]0,005...2
Measuring range [°F]-4...176
Resolution [°F]0.5
Set point SP [°F]-2.5...176
Reset point rP [°F]-3.5...175
Analog start point [°F]-4...140.5
Analog end point [°F]31.5...176
In steps of [°F]0.5
Accuracy (in the measuring range)± (0,8 % MW + 0,5 % MEW)
Repeatability± 0,2% MEW
Accuracy [K]± 2,5 (Q > 0,26 gpm)
Время отклика0.15; (dAP = 0, T19)
Delay time programmable dS, dr [s]0...50
Damping process value dAP [s]0...5
Dynamic response T05 / T09 [s]T09 = 20 (Q > 0,26 gpm)
Parameter setting optionsFlow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / closed; switching logic; current/voltage/pulse output; Start-up delay; display can be deactivated; Display unit
Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
ProfilesSmart Sensor - SSP 0: Generic Profiled Sensor; Function: Device identification; Function: Process data variable; Function: Device diagnosis
SIO modeyes
Required master port classA
Process data analog3
Process data binary2
Min. process cycle time [ms]5
Supported DeviceIDsType of operation: DeviceID; default: 573
Рабочая температура14...140
Storage temperature [°F]-13...176
ProtectionIP 67
EMCDIN EN 60947-5-9
Shock resistanceDIN IEC 68-2-27: 20 g (11 ms)
Vibration resistanceDIN IEC 68-2-6: 5 g (10...2000 Hz)
MTTF [years]145
Pressure equipment directivesound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Масса586
Housingtubular
Inlet pipe length3 x DN
Outlet pipe length1 x DN
Dimensions [mm]Ø 54 / L = 110
Материалstainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE
Материалstainless steel (1.4404 / 316L); PEEK; FKM
DisplayDisplay unit: 6 x LED, green (gpm, gph, gal, °F, 10³, 1000 x 10³); Switching status: 2 x LED, yellow; Measured values: alphanumeric display, 4-digit; Programming: alphanumeric display, 4-digit
RemarksMW = Measured value; MEW = Final value of the measuring range
Pack quantity1 pcs.
Connector1 x M12; coding: A; Contacts: 4, gold-plated
Получить предложение по этой позиции