SM7004

ifm electronic gmbh SM7004

Magnetic-inductive flow meter, SMR34GGX50KG/US100

  • Бренд: ifm electronic gmbh
  • Артикул (MPN): SM7004
  • Статус производства: Не определён

Категории:

Технические характеристики

Number of inputs and outputsNumber of analog outputs: 2
Measuring range0.2...50 l/min: 0.02...13.22 gpm
Process connectionthreaded connection G 3/4 external thread DN20 flat seal
Special featuregold-plated contacts
Applicationfor industrial applications
Installationconnection to pipe by means of an adapter
MediaConductive liquids; water; water-based media
Note on mediaconductivity: ≥ 20 µS/cm; viscosity: < 70 mm²/s (40 °C)
Medium temperature [°C]-10...70
Pressure rating16 bar: 1.6 MPa
MAWP (for applications according to CRN)10.4 bar: 1.04 MPa
Напряжение питания20...30 DC; (to SELV/PELV)
Current consumption [mA]120; (24 V)
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]5
Measuring principlemagnetic-inductive
Total number of outputs2
Output signalanalog signal
Number of analog outputs2
Analog current output [mA]4...20; (scalable)
Max. load [Ω]500
Overload protectionyes
Display range-60...60 l/min: -15.86...15.86 gpm
Resolution0.1 l/min: 0.02 gpm
Analog start point ASP0...40 l/min: 0...10.58 gpm
Analog end point AEP10...50 l/min: 2.64...13.22 gpm
In steps of0.1 l/min: 0.02 gpm
Measuring range [°C]-20...80
Resolution [°C]0.2
Analog start point [°C]-20...60
Analog end point [°C]0...80
In steps of [°C]0.2
Accuracy (in the measuring range)± (2 % MW + 0,5 % MEW)
Repeatability± 0,2% MEW
Accuracy [K]± 2,5 (Q > 1 l/min)
Время отклика0.15; (dAP = 0, T19)
Damping process value dAP [s]0...3
Dynamic response T05 / T09 [s]T09 = 20 (Q > 1 l/min)
Рабочая температура-10...60
Storage temperature [°C]-25...80
ProtectionIP 67
EMCDIN EN 60947-5-9: 500 V withstand voltage (V DC)
CPA approvalmodel number: 008MI; accuracy class: -; maximum allowable error: ± 2,5 % FS; Q (min): 0,01 m³/h; Q (t): -; Q (max): 3 m³/h
Shock resistanceDIN IEC 68-2-27: 20 g (11 ms)
Vibration resistanceDIN IEC 68-2-6: 5 g (10...2000 Hz)
MTTF [years]175
Pressure equipment directivesound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Масса521.2
Housingtubular
Inlet pipe length3 x DN
Outlet pipe length1 x DN
Dimensions [mm]Ø 54 / L = 110
Материалstainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE
Материалstainless steel (1.4404 / 316L); PEEK; FKM
DisplayDisplay unit: 6 x LED, green (l/min, m³/h, gpm, gph, °C, °F); Measured values: alphanumeric display, 4-digit; Programming: alphanumeric display, 4-digit
Display unitl/min; m³/h; gpm; gph; °C; °F
RemarksMW = Measured value; MEW = Final value of the measuring range
Pack quantity1 pcs.
Connector1 x M12; coding: A; Contacts: 4, gold-plated