ifm electronic gmbh SM9100
Magnetic-inductive flow meter, SMR21XGXFRKG/US
Категории:
Технические характеристики
| Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
|---|---|
| Measuring range | 5...300 l/min: 0.3...18 m³/h |
| Process connection | threaded connection G 2 external thread DN50 flat seal |
| Special feature | gold-plated contacts |
| Application | Totalizer function; empty pipe detection; for industrial applications |
| Installation | connection to pipe by means of an adapter |
| Media | Conductive liquids; water; water-based media |
| Note on media | conductivity: ≥ 20 µS/cm; viscosity: < 70 mm²/s (40 °C) |
| Medium temperature [°C] | -10...90 |
| Pressure rating | 16 bar: 1.6 MPa |
| MAWP (for applications according to CRN) | 8.9 bar: 0.89 MPa |
| Напряжение питания | 18...32 DC; (to SELV/PELV) |
| Current consumption [mA] | < 150 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | 5 |
| Measuring principle | magnetic-inductive |
| Inputs | counter reset |
| Total number of outputs | 2 |
| Output signal | switching signal; analog signal; pulse signal; frequency signal; IO-Link; (configurable) |
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / closed; (configurable) |
| Напряжение питания | 2 |
| Permanent current rating of switching output DC [mA] | 250; (per output) |
| Number of analog outputs | 1 |
| Analog current output [mA] | 4...20; (scalable) |
| Max. load [Ω] | 500 |
| Напряжение питания | 0...10; (scalable) |
| Min. load resistance [Ω] | 2000 |
| Pulse output | flow rate meter |
| Short-circuit protection | yes |
| Type of short-circuit protection | yes (non-latching) |
| Overload protection | yes |
| Frequency of the output [Hz] | 0.1...10000 |
| Display range | -360...360 l/min: -21.6...21.6 m³/h |
| Resolution | 0.5 l/min: 0.02 m³/h |
| Set point SP | 6.5...300 l/min: 0.4...18 m³/h |
| Reset point rP | 5...298.5 l/min: 0.3...17.9 m³/h |
| Analog start point ASP | 0...240 l/min: 0...14.4 m³/h |
| Analog end point AEP | 60...300 l/min: 3.6...18 m³/h |
| Low flow cut-off LFC | < 15 l/min: < 0.9 m³/h |
| In steps of | 0.0001 m³ |
| Measuring dynamics | 1:60 |
| Pulse value | 0.0001...300 x 10³ m³ |
| Pulse length [s] | 0,016...2 |
| Measuring range [°C] | -20...80 |
| Display range [°C] | -40...100 |
| Resolution [°C] | 0.2 |
| Set point SP [°C] | -19.2...80 |
| Reset point rP [°C] | -19.6...79.6 |
| Analog start point [°C] | -20...60 |
| Analog end point [°C] | 0...80 |
| In steps of [°C] | 0.2 |
| Accuracy (in the measuring range) | ± (0,8 % MW + 0,5 % MEW) |
| Repeatability | ± 0,2% MEW |
| Temperature drift | ± 0,0333 °C / K |
| Accuracy [K] | ± 1 (25 °C; Q > 15 l/min) |
| Время отклика | 0.35; (dAP = 0) |
| Delay time programmable dS, dr [s] | 0...50 |
| Damping process value dAP [s] | 0...5 |
| Dynamic response T05 / T09 [s] | T09 = 3 (Q > 15 l/min) |
| Parameter setting options | Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / closed; switching logic; current/voltage/frequency/pulse output; Start-up delay; display can be deactivated; Display unit; empty pipe detection |
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 CDV |
| Profiles | Smart Sensor - SSP 0: Generic Profiled Sensor; Function: Device identification; Function: Process data variable |
| SIO mode | yes |
| Required master port class | A |
| Process data analog | 3 |
| Process data binary | 2 |
| Min. process cycle time [ms] | 5 |
| Supported DeviceIDs | Type of operation: DeviceID; default: 391 |
| Рабочая температура | -10...60 |
| Storage temperature [°C] | -25...80 |
| Protection | IP 65; IP 67 |
| EMC | DIN EN 60947-5-9 |
| CPA approval | model number: 004MI; accuracy class: -; maximum allowable error: ± 1,5 % FS; Q (min): 0,3 m³/h; Q (t): -; Q (max): 18 m³/h; Medium temperature: -10...70°C |
| Shock resistance | DIN EN 60068-2-27: 20 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6: 5 g (10...2000 Hz) |
| MTTF [years] | 85 |
| UL approval | UL approval number: I008; File number UL: E174189 |
| Pressure equipment directive | sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Масса | 3050 |
| Housing | rectangular |
| Inlet pipe length | 3 x DN |
| Outlet pipe length | 1 x DN |
| Dimensions [mm] | 200 x 103 x 117 |
| Материал | stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEI; FKM; PBT-GF20; TPE-U |
| Материал | Pipe section: stainless steel (1.4404 / 316L); Process connection sealing: NBR fiber-reinforced Gasket; stainless steel (1.4571/316Ti ); PEEK; EPDM |
| Display | Display unit: 6 x LED, green (l/min, m³/h, l, m³, 10³, °C); Switching status: 2 x LED, yellow; Measured values: alphanumeric display, 4-digit; Programming: alphanumeric display, 4-digit |
| Items supplied | sealings: 2, Centellen; Label |
| Remarks | MW = Measured value; MEW = Final value of the measuring range |
| Pack quantity | 1 pcs. |
| Connector | 1 x M12; coding: A; Contacts: 4, gold-plated |