SMF950

ifm electronic gmbh SMF950

Magnetic-inductive flow meter, SMGX2KGFFRKG/UST

  • Бренд: ifm electronic gmbh
  • Артикул (MPN): SMF950
  • Статус производства: Не определён

Категории:

Технические характеристики

Measuring range-20...150 °C: -4...302 °F
Nominal diameterDN150 (6“)
Process connectionifm-specific device flange
Special featuregold-plated contacts
Applicationfood and beverage industry
MediaConductive liquids; water; water-based media
Note on mediafood products such as beer, milk, fruit juices, soft drinks, ketchup, yogurt, yogurt toppings, ice cream; conductivity: ≥ 5 µS/cm
Medium temperature [°C]-20...150
Min. burst pressure24 bar: 348 psi: 2.4 MPa
Pressure rating16 bar: 232 psi: 1.6 MPa
Напряжение питания18...32 DC
Current consumption [mA]250; (24 V)
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]< 5
Measuring principlemagnetic-inductive
Total number of inputs and outputs2
InputsOUT2: external totalizer reset
Total number of outputs2
Output signalOUT1: pulse signal; totalizer switching signal; diagnostic signal; IO-Link; OUT2: analog signal; pulse signal; totalizer switching signal; diagnostic signal
Electrical designPNP/NPN
Pulse outputflow rate meter
Short-circuit protectionyes
Type of short-circuit protectionyes (non-latching)
Overload protectionyes
Number of analog outputs1
Analog current output [mA]4...20; (skalierbar)
Max. load [Ω]500
Resolution of analog output0.38 µA
Number of digital outputs2
Напряжение питания2
Permanent current rating of switching output DC [mA]100
Switching frequency DC [Hz]0...10000
Note on factory setting0...160,0 m³/h
Analog start point ASP-10000...8000 l/min: -600...480 m³/h: -2642...2113 gpm: -30.94...24.75 ft/s
Analog end point AEP-8000...10000 l/min: -480...600 m³/h: -2113...2642 gpm: -24.75...30.94 ft/s
Low flow cut-off LFC0...8000 l/min: 0...480 m³/h: 0...2113 gpm: 0...24.75 ft/s
Pulse length [s]0.00005...2
Pulse value0.017...99999000 I
Analog start point-20...116 °C: -4...240.8 °F
Analog end point14...150 °C: 57.2...302 °F
Measuring range [µS/cm]100...100000
Analog start point [µS/cm]0...80000
Analog end point [µS/cm]20000...100000
Accuracy (in the measuring range)in the range of 100...20000 µS/cm: ±10% MW; in the range of 20000...100000 µS/cm: ±20% MW
Repeatability± 5% MW
Accuracy [K]± 1 (v > 0,5 m/s)
Repeatability [K]± 0,5 (v > 0,5 m/s)
Время отклика< 2
Damping process value dAP [s]0...5
Diagnostic functionsdirection of flow detection; liquid detection
Communication interfaceIO-Link
Transmission typeCOM3 (230,4 kBaud)
IO-Link revision1.1.3
SDCI standardIEC 61131-9
ProfilesSmart Sensor - SSP 4.3.4: Measuring and Switching Sensor, floating point, 4 channel; BLOB: Binary Large Object transfer; Common - I&D: Identification and Diagnosis; Extension: Sensor Control Wide; Extension: Quantity detection, switches when value exceeds the setpoint; Function: Locator; Function: ProductURI
SIO modeyes
Required master port classA
Process data analog6
Process data binary8
Min. process cycle time [ms]1.9
IO-Link process data (cyclical)Function: bit length; totalizer: 32; flow: 32; temperature: 32; conductivity: 32; status: 4; binary switching information: 8
IO-Link functions (acyclical)direction of flow detection; totalizer; memory; operating hours counter; internal temperature; simulation function
Supported DeviceIDsType of operation: DeviceID; default: 1809
Рабочая температура-20...65 °C: -4...149 °F
Storage temperature-20...80 °C: -4...176 °F
ProtectionIP 67; IP 69; (to DIN EN 60529)
EMCDIN 61326-1
Shock resistanceDIN IEC 68-2-27: 20 g (18ms)
Vibration resistanceDIN IEC 68-2-6: 5 g (10...2000Hz)
MTTF [years]83
UL approvalUL approval number: I032; File number UL: E174189
Pressure equipment directivesound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Масса20800
Housingtubular
Inlet pipe length5 x DN
Outlet pipe length2 x DN
Dimensions [mm]Ø 255 / L = 200
Материалhousing: stainless steel (1.4404 / 316L); flange: stainless steel (1.4301 / 304); electronics fixture: stainless steel (1.4301 / 304); electronics: stainless steel (1.4404 / 316L); LED ring: PP
МатериалPipe section: PFA; electrodes: stainless steel (1.4435 / 316L)
Surface characteristics Ra/Rz of the wetted partsRa < 0.4 μm
Displayoperating status: LED ring, three-color
Factory settingm³/h; °C; μS/cm
RemarksMW = Measured value; MEW = Final value of the measuring range; pulse and totalizer signal are only available for one of the two outputs; reference conditions (1/2): water (free of gas bubbles), 15...35 °C, process connection: DIN32676 series A, pipe standard suitable for process connection; reference conditions (2/2): inlet pipe length 10xDN, outlet pipe length 5xDN, device settling time: 30 minutes, device orientation: horizontal, display orientation: up; accuracy specifications according to factory certificate on delivery
NotesFür die Inbetriebnahme des Sensors werden zusätzlich ein passender Prozessadapter und eine Dichtung benötigt.; Die passenden Produkte finden Sie im Zubehör.
Pack quantity1 pcs.
Connector1 x M12; coding: A; Contacts: 4, gold-plated
Получить предложение по этой позиции