SU7030

ifm electronic gmbh SU7030

Ultrasonic flow meter, SUR34XFBFRKG/US

  • Бренд: ifm electronic gmbh
  • Артикул (MPN): SU7030
  • Статус производства: Не определён

Технические характеристики

Measuring range0.5...75 l/min: 30...4500 l/h: 0.104...15.601 m/s: 0.03...4.5 m³/h
Process connectionthreaded connection G 3/4 external thread DN20
Special featuregold-plated contacts
Mediaultra-pure water; water; water-based media; glycol solutions; oils; Coolants
Note on mediawater-based media: for media with >10 % additives, the repeatability is the only available value; low-viscosity oils with viscosity: 7...40 mm²/s (40 °C); high-viscosity oils with viscosity: 30...68 mm²/s (40 °C)
Medium temperature [°C]-20...100
Min. burst pressure150 bar: 15 MPa
Pressure rating100 bar: 10 MPa
Vacuum resistance [mbar]-1000
Напряжение питания18...32 DC; (to SELV/PELV)
Current consumption [mA]< 75
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]5
Measuring principleultrasonic
Inputscounter reset
Total number of outputs2
Output signalswitching signal; pulse signal; analog signal; IO-Link; frequency signal; diagnostic signal; totalizer switching signal
Electrical designPNP/NPN
Output functionnormally open / closed; (configurable)
Напряжение питания2
Permanent current rating of switching output DC [mA]100
Switching frequency DC [Hz]0...10000
Analog current output [mA]4...20
Max. load [Ω]500
Pulse outputflow rate meter
Short-circuit protectionyes
Type of short-circuit protectionyes (non-latching)
Overload protectionyes
Display range-90...90 l/min: -5400...5400 l/h: -18.721...18.721 m/s: -5.4...5.4 m³/h
Resolution0.1 l/min: 2 l/h: 0.001 m/s: 0.002 m³/h
Set point SP0.9...75 l/min: 55...4500 l/h: 0.192...15.601 m/s: 0.055...4.5 m³/h
Reset point rP0.5...74.6 l/min: 32...4477 l/h: 0.112...15.521 m/s: 0.032...4.477 m³/h
Analog start point ASP-75...60 l/min: -4500...3600 l/h: -15.604...12.481 m/s: -4.5...3.6 m³/h
Analog end point AEP-60...75 l/min: -3600...4500 l/h: -12.481...15.601 m/s: -3.6...4.5 m³/h
Low flow cut-off LFC0.5...3.2 l/min: 30...195 l/h: 0.104...0.676 m/s: 0.03...0.195 m³/h
Frequency end point, FEP15...75 l/min: 903...4500 l/h: 3.13...15.601 m/s: 0.903...4.5 m³/h
Frequency at the end point FRP [Hz]1...10000
Pulse length [s]0.002...2
Pulse value0.02...99990000 l
Measuring range [°C]-20...100
Display range [°C]-44...124
Resolution [°C]0.1
Set point SP [°C]-19.6...100
Reset point rP [°C]-20...99.6
Analog start point [°C]-20...76
Analog end point [°C]4...100
Frequency start point, FSP [°C]-20...76
Frequency end point, FEP [°C]4...100
Accuracy (in the measuring range)glycol solutions (35%): ±(5,0 % MW + 0,5 % MEW); high-viscosity oils with viscosity 46mm2/s (40°C): ±(5,0 % MW + 1,0 % MEW); low-viscosity oils with viscosity 10mm2/s (40°C): ±(5,0 % MW + 1,0 % MEW); water: ± (2,0 % MW + 0,5 % MEW)
Repeatability± 0,2 % MEW
Accuracy [K]± 2,5 (Q > 5 % MEW)
Temperature coefficient [% of the span / 10 K]0,2
Время отклика< 0.25; (dAP = 0, T09)
Damping process value dAP [s]0...5
Dynamic response T05 / T09 [s]5,7 / 86
Diagnostic functionsdirection of flow detection; signal quality
Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1.3
SDCI standardIEC 61131-9: 2013-07
ProfilesBLOB: Binary Large Object transfer; Common - I&D: Identification and Diagnosis
Required master port classA
Process data analog3
Process data binary2
Min. process cycle time [ms]9.6
IO-Link process data (cyclical)Function: bit length; totalizer: 32; Flow monitoring: 32; Temperature monitoring: 32; status: 4; Output 1: 1; Output 2: 1
Supported DeviceIDsType of operation: DeviceID; default: 1756
Рабочая температура-20...60
Storage temperature [°C]-25...80
ProtectionIP 65; IP 67
EMCDIN 61326-1:2021
Shock resistanceDIN IEC 68-2-27: 20 g (11ms)
Vibration resistanceDIN IEC 68-2-6: 20 g (10...2000Hz)
MTTF [years]160
UL approvalUL approval number: I034
Pressure equipment directivecan be used for group 2 fluids; group 1 fluids on request
Масса492.8
Housingrectangular
Type of mountinginlet pipe length 5xDN; outlet pipe length 1xDN
Dimensions [mm]110 x 48 x 57.8
Материалhousing: stainless steel (1.4404 / 316L); Display: PFA; sealing Display: FKM; connector: PBT
МатериалPipe section: stainless steel (1.4404 / 316L); Process connection sealing: NBR fiber-reinforced Gasket
Surface characteristics Ra/Rz of the wetted partsRa < 1.25 µm
DisplayColor display 1,44", 128 x 128 pixels; Switching function: 2 x LED, yellow; diagnosis: 1 x LED, three-color
Display unitl/min; l/h; m³/h; m/s
Items suppliedGasket 2, Centellen; package insert
RemarksMW = Measured value; MEW = Final value of the measuring range; pulse and totalizer signal are only available for one of the two outputs; the accuracy indications are adhered to over the entire application area
Pack quantity1 pcs.
Connector1 x M12; coding: A; Contacts: 4, gold-plated