Ultrasonic flow meter, SUO50IGAFRKG/US

  • Бренд: ifm electronic gmbh
  • Артикул (MPN): SUC301
  • Статус производства: Не определён

Технические характеристики

Measuring range-20...100 °C: -4...212 °F
Nominal diameterDN40 (1 1/2"); DN50 (2")
Process connectionclamp-on
Special featuregold-plated contacts
ApplicationUse in industrial applications
Mediaultra-pure water; water; water-based media
Note on mediawater-based media: for media with >10 % additives, the repeatability is the only available value
Medium temperature-20...100 °C: -4...212 °F
Материалmetal: steel; stainless steel, copper; plastics: PVC; CPVC; PP
Outer diameter [mm]44...64
Wall thickness [mm]0,1...11,1
Напряжение питания18...32 DC; (to SELV/PELV)
Current consumption [mA]< 75
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]5
Measuring principleultrasonic
Total number of inputs and outputs2
InputsOUT2: counter reset
Total number of outputs2
Output signalOUT1: switching signal; pulse signal; diagnostic signal; totalizer switching signal; frequency signal; IO-Link; OUT2: switching signal; pulse signal; diagnostic signal; totalizer switching signal; analog signal
Electrical designPNP/NPN
Pulse outputflow rate meter
Short-circuit protectionyes
Type of short-circuit protectionyes (non-latching)
Overload protectionyes
Number of analog outputs1
Analog current output [mA]4...20
Max. load [Ω]500
Number of digital outputs2
Output functionnormally open / closed; (configurable)
Напряжение питания2
Permanent current rating of switching output DC [mA]100
Switching frequency DC [Hz]0...10000
Display range0...1200 l/min: 0...72 m³/h: 0...19020 gph: 0...317 gpm
Resolution0.1 °C: 0.1 °F
Set point SP-19.6...100 °C: -3.2...212 °F
Reset point rP-20...99.6 °C: -4...211.2 °F
Analog start point ASP-1000...800 l/min: -60...48 m³/h: -15850...12680 gph: -264.17...211.34 gpm
Analog end point AEP-800...1000 l/min: -48...60 m³/h: -12680...15850 gph: -211.34...264.17 gpm
Low flow cut-off LFC20...50 l/min: 1.2...3 m³/h: 320...790 gph: 5.3...13.21 gpm
Frequency end point, FEP4...100 °C: 39.2...212 °F
Frequency at the end point FRP [Hz]1...10000
Analog start point-20...76 °C: -4...168.8 °F
Analog end point4...100 °C: 39.2...212 °F
Frequency start point, FSP-20...76 °C: 4...168.8 °F
Pulse length [s]0.002...2
Pulse value0.1...99990000 l; 0.026...26414563.515 gal
Accuracy (in the measuring range)water "reference conditions": ± (2,0 % MW + 0,5 % MEW); water: ± (5,0 % MW + 0,5 % MEW)
Repeatability± 0,2 % MEW
Accuracy [K]temperature reference conditions: ± 5 (Q > 5 % MEW)
Temperature coefficient [% of the span / 10 K]0,2
Время отклика< 0.25; (dAP = 0, T09)
Damping process value dAP [s]0...5
Dynamic response T05 / T09 [s]62 / 263
Diagnostic functionsdirection of flow detection; signal quality
Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
ProfilesBLOB: Binary Large Object transfer; Common - I&D: Identification and Diagnosis; Function: Locator; Function: ProductURI
Required master port classA
Process data analog3
Process data binary2
Min. process cycle time [ms]9.6
IO-Link process data (cyclical)Function: bit length; totalizer: 32; Flow monitoring: 32; Temperature monitoring: 32; status: 4; Output 1: 1; Output 2: 1
Supported DeviceIDsType of operation: DeviceID; default: 2002
Рабочая температура-20...60
Storage temperature [°C]-25...80
Max. relative air humidity [%]90; (non condensing)
ProtectionIP 67; IP 69; (DIN EN 60529)
EMCDIN 61326-1:2021
Shock resistanceDIN IEC 68-2-27: 20 g (11ms)
Vibration resistanceDIN IEC 68-2-6: 20 g (10...2000Hz)
MTTF [years]160
UL approvalUL approval number: I040; File number UL: E174189
Масса655
Housingrectangular
Inlet pipe length10 x DN
Outlet pipe length5 x DN
Dimensions [mm]101.9 x 88 x 123.1
Материалhousing: stainless steel (1.4404 / 316L); clamp: stainless steel (17-4 PH/1.4542); Display: PFA; sealing Display: FKM; connector: PBT; couplant: EPDM
DisplayColor display 1,44", 128 x 128 pixels; Switching function: 2 x LED, yellow; diagnosis: 1 x LED, three-color
Display unitl/min; m³/h; gph; gpm; °C; °F
Factory settinggpm; °F
LanguageGerman; English; Spanish; French; Italian; Japanese; Korean; Portuguese; Chinese
Items suppliedcouplant, E33911
RemarksMW = Measured value; MEW = Final value of the measuring range; pulse and totalizer signal are only available for one of the two outputs; Installation on a clean pipe (avoid rust, frost and condensation on the surface and weld seams).; to achieve a measurement accuracy of 2 %, the specified reference conditions must be observed:; medium water free of gas bubbles, temperature 25°C, nominal diameter DN50 (2"), pipe material stainless steel; Accuracy is achieved with optimized setup:; •90% water-based media; • Pipe material is correctly selected; •Outer diameter is entered correctly within +/- 0.1mm; • Wall thickness is automatically measured or accurately entered
Pack quantity1 pcs.
Connector1 x M12; coding: A; Contacts: 4, gold-plated