SUH120

ifm electronic gmbh SUH120

Ultrasonic flow meter, SUC15XJBFRKG/US

  • Бренд: ifm electronic gmbh
  • Артикул (MPN): SUH120
  • Статус производства: Не определён

Технические характеристики

Measuring range-40...125 °C: -40...257 °F
Nominal diameterDN15 (1/2“)
Process connectionClamp DN15 DIN 32676 series A
Special featuregold-plated contacts
Applicationfood and beverage industry
Mediaultra-pure water; water; water-based media; edible oils
Note on mediawater-based media: for media with >10 % additives, the repeatability is the only available value; edible oils: palm oil, soy oil, rapeseed oil, sunflower oil, peanut oil, olive oil and others
Medium temperature [°C]-40...125; (< 1 h: 150)
Min. burst pressure75 bar: 7.5 MPa
Pressure rating25 bar: 2.5 MPa
Note on pressure ratingtake into account the pressure resistance of the bracket and the seal used for clamp connection
Vacuum resistance [mbar]-1000
Напряжение питания18...32 DC; (to SELV/PELV)
Current consumption [mA]< 75
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]5
Measuring principleultrasonic
Total number of inputs and outputs2
InputsOUT2: counter reset
Total number of outputs2
Output signalOUT1: switching signal; pulse signal; diagnostic signal; totalizer switching signal; frequency signal; IO-Link; OUT2: switching signal; pulse signal; diagnostic signal; totalizer switching signal; analog signal
Electrical designPNP/NPN
Pulse outputflow rate meter
Short-circuit protectionyes
Type of short-circuit protectionyes (non-latching)
Overload protectionyes
Number of analog outputs1
Analog current output [mA]4...20
Max. load [Ω]500
Number of digital outputs2
Output functionnormally open / closed; (configurable)
Напряжение питания2
Permanent current rating of switching output DC [mA]100
Switching frequency DC [Hz]0...10000
Resolution0.1 °C: 0.1 °F
Note on factory settingl/min, °C
Set point SP-39.4...125 °C: -38.9...257 °F
Reset point rP-40...124.4 °C: -40...255.9 °F
Analog start point ASP-65...52 l/min: -3.9...3.12 m³/h: -1030...824 gph: -17.17...13.74 gpm
Analog end point AEP-52...65 l/min: -3.12...3.9 m³/h: -824...1030 gph: -13.74...17.17 gpm
Low flow cut-off LFC1...3.2 l/min: 0.06...0.195 m³/h: 16...52 gph: 0.26...0.86 gpm
Frequency end point, FEP-7...125 °C: 19.4...257 °F
Frequency at the end point FRP [Hz]1...10000
Pulse length [s]0.002...2
Pulse value0.1...99990000 I / 0.026...26414563.515 gal
Analog start point-40...92 °C: -40...197.6 °F
Analog end point-7...125 °C: 19.4...257 °F
Frequency start point, FSP-40...92 °C: -40...197.6 °F
Accuracy (in the measuring range)water: ± (2,0 % MW + 0,5 % MEW)
Repeatability± 0,2 % MEW
Accuracy [K]± 2,5 (Q > 5 % MEW)
Temperature coefficient [% of the span / 10 K]0,2
Время отклика< 0.3; (dAP = 0, T09)
Damping process value dAP [s]0...5
Dynamic response T05 / T09 [s]5,7 / 86
Diagnostic functionsdirection of flow detection; signal quality
Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1.3
SDCI standardIEC 61131-9: 2013-07
ProfilesBLOB: Binary Large Object transfer; Common - I&D: Identification and Diagnosis
Required master port classA
Process data analog3
Process data binary2
Min. process cycle time [ms]9.6
IO-Link process data (cyclical)Function: bit length; totalizer: 32; Flow monitoring: 32; Temperature monitoring: 32; status: 4; Output 1: 1; Output 2: 1
Supported DeviceIDsType of operation: DeviceID; default: 1907
Рабочая температура-20...60
Storage temperature [°C]-25...80
ProtectionIP 69; (DIN EN 60529)
EMCDIN 61326-1:2021
Shock resistanceDIN IEC 68-2-27: 20 g (11ms)
Vibration resistanceDIN IEC 68-2-6: 20 g (10...2000Hz)
MTTF [years]136
UL approvalUL approval number: I039; File number UL: E174189
Pressure equipment directivecan be used for group 2 fluids; group 1 fluids on request
Масса523.1
Housingrectangular
Inlet pipe length5 x DN
Outlet pipe length1 x DN
Dimensions [mm]168 x 48 x 61.1
Материалhousing: stainless steel (1.4404 / 316L); connector: PEI, FKM
МатериалPipe section: stainless steel (1.4435 / 316L); Process connection: stainless steel (1.4404 / 316L)
Process connection suitable for pipe standardDN15 / Ø 19 mm x 1,5 mm; (DIN 11866 series A); (DIN EN 10357 series A)
Surface characteristics Ra/Rz of the wetted partsRa < 0.4 µm (16 µin); Rz = 4 µm (157 µin)
Displayoperating status: 1 x LED, green
Items suppliedpackage insert
RemarksMW = Measured value; MEW = Final value of the measuring range; pulse and totalizer signal are only available for one of the two outputs; the specified surface characteristics Ra/Rz of the wetted surfaces do not apply to the weld seam.
Pack quantity1 pcs.
Connector1 x M12; coding: A; Contacts: 4, gold-plated