SUH201

ifm electronic gmbh SUH201

Ultrasonic flow meter, SUC25IJBFRKG/US

  • Бренд: ifm electronic gmbh
  • Артикул (MPN): SUH201
  • Статус производства: Не определён

Технические характеристики

Measuring range-20...100 °C: -4...212 °F
Nominal diameterDN25 (1“)
Process connectionClamp 1" DIN 32676 series C (ASME BPE)
Special featuregold-plated contacts
Mediaultra-pure water; water; water-based media; edible oils
Note on mediawater-based media: for media with >10 % additives, the repeatability is the only available value; edible oils: palm oil, soy oil, rapeseed oil, sunflower oil, peanut oil, olive oil and others
Medium temperature-20...100 °C: -4...212 °F
Min. burst pressure75 bar: 7.5 MPa
Pressure rating25 bar: 2.5 MPa
Note on pressure ratingtake into account the pressure resistance of the bracket and the seal used for clamp connection
Vacuum resistance [mbar]-1000
Напряжение питания18...32 DC; (to SELV/PELV)
Current consumption [mA]< 75
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]5
Measuring principleultrasonic
Total number of inputs and outputs2
InputsOUT2: counter reset
Total number of outputs2
Output signalOUT1: switching signal; pulse signal; diagnostic signal; totalizer switching signal; frequency signal; IO-Link; OUT2: switching signal; pulse signal; diagnostic signal; totalizer switching signal; analog signal
Electrical designPNP/NPN
Min. load resistance [Ω]2000
Pulse outputflow rate meter
Short-circuit protectionyes
Type of short-circuit protectionyes (non-latching)
Overload protectionyes
Number of analog outputs1
Analog current output [mA]4...20
Max. load [Ω]500
Number of digital outputs2
Output functionnormally open / closed; (configurable)
Напряжение питания2
Permanent current rating of switching output DC [mA]100
Switching frequency DC [Hz]0...10000
Display range-44...124 °C: -47.2...255.2 °F
Resolution0.1 °C: 0.1 °F
Set point SP-19.6...100 °C: -3.2...212 °F
Reset point rP-20...99.6 °C: -4...211.2 °F
Analog start point ASP-240...192 l/min: -14.4...11.522 m³/h: -3804...3044 gph: -63.4...50.73 gpm
Analog end point AEP-191.9...240 l/min: -11.511...14.4 m³/h: -3041...3804 gph: -50.68...63.4 gpm
Low flow cut-off LFC1...12 l/min: 0.06...0.72 m³/h: 16...190 gph: 0.26...3.17 gpm
Frequency end point, FEP4...100 °C: 39.2...212 °F
Frequency at the end point FRP [Hz]1...10000
Pulse length [s]0.002...2
Pulse value0.02...99990000 l; 0.0053...26414563.515 gal
Analog start point-20...76 °C: -4...168.8 °F
Analog end point4...100 °C: 39.2...212 °F
Frequency start point, FSP-20...76 °C: -4...168.8 °F
Accuracy (in the measuring range)edible oils: ± (5,0 % MW + 1,0 % MEW); water: ± (1,0 % MW + 0,5 % MEW)
Repeatability± 0,2 % MEW
Accuracy [K]± 2,5 (Q > 5 % MEW)
Temperature coefficient [% of the span / 10 K]0,2
Время отклика< 0.25; (dAP = 0, T09)
Damping process value dAP [s]0...5
Dynamic response T05 / T09 [s]5,7 / 86
Diagnostic functionsdirection of flow detection; signal quality
Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1.3
SDCI standardIEC 61131-9: 2013-07
ProfilesBLOB: Binary Large Object transfer; Common - I&D: Identification and Diagnosis
Required master port classA
Process data analog3
Process data binary2
Min. process cycle time [ms]9.6
IO-Link process data (cyclical)Function: bit length; totalizer: 32; Flow monitoring: 32; Temperature monitoring: 32; status: 4; Output 1: 1; Output 2: 1
Supported DeviceIDsType of operation: DeviceID; default: 1751
Рабочая температура-20...60
Storage temperature [°C]-25...80
ProtectionIP 69K
EMCDIN 61326-1:2021
CPA approvalmodel number: 003US; accuracy class: 1,5
Shock resistanceDIN IEC 68-2-27: 20 g (11ms)
Vibration resistanceDIN IEC 68-2-6: 20 g (10...2000Hz)
MTTF [years]160
UL approvalUL approval number: I034; File number UL: E174189
Pressure equipment directivecan be used for group 2 fluids; group 1 fluids on request
Масса639.4
Housingrectangular
Inlet pipe length5 x DN
Outlet pipe length1 x DN
Dimensions [mm]175 x 50.4 x 73.8
Материалhousing: stainless steel (1.4404 / 316L); Display: PFA; sealing Display: FKM; connector: PBT
МатериалPipe section: stainless steel (1.4404 / 316L)
Process connection suitable for pipe standard1" / Ø 25,4 mm x 1,65 mm (DIN 11866 series C); (DIN EN 10357 Series D)
Surface characteristics Ra/Rz of the wetted partsRa < 0.8 μm (32 µin)
DisplayColor display 1,44", 128 x 128 pixels; Switching function: 2 x LED, yellow; diagnosis: 1 x LED, three-color
RemarksMW = Measured value; MEW = Final value of the measuring range; pulse and totalizer signal are only available for one of the two outputs; the accuracy indications are adhered to over the entire application area
Pack quantity1 pcs.
Connector1 x M12; coding: A; Contacts: 4, gold-plated
Получить предложение по этой позиции