ifm electronic gmbh SUH230
Ultrasonic flow meter, SUG25IGBFRKG/US
Технические характеристики
| Measuring range | 1...240 l/min: 60...14400 l/h: 0.051...12.202 m/s: 0.06...14.4 m³/h |
|---|---|
| Nominal diameter | DN25 (1“) |
| Process connection | ifm-specific device flange |
| Special feature | gold-plated contacts |
| Media | ultra-pure water; water; water-based media; edible oils |
| Note on media | water-based media: for media with >10 % additives, the repeatability is the only available value; edible oils: palm oil, soy oil, rapeseed oil, sunflower oil, peanut oil, olive oil and others |
| Medium temperature [°C] | -20...100 |
| Min. burst pressure | 75 bar: 7.5 MPa |
| Pressure rating | 40 bar: 4 MPa |
| Vacuum resistance [mbar] | -1000 |
| Напряжение питания | 18...32 DC; (to SELV/PELV) |
| Current consumption [mA] | < 75 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | 5 |
| Measuring principle | ultrasonic |
| Total number of inputs and outputs | 2 |
| Inputs | OUT2: counter reset |
| Total number of outputs | 2 |
| Output signal | OUT1: switching signal; pulse signal; diagnostic signal; totalizer switching signal; frequency signal; IO-Link; OUT2: switching signal; pulse signal; diagnostic signal; totalizer switching signal; analog signal |
| Electrical design | PNP/NPN |
| Min. load resistance [Ω] | 2000 |
| Pulse output | flow rate meter |
| Short-circuit protection | yes |
| Type of short-circuit protection | yes (non-latching) |
| Overload protection | yes |
| Number of analog outputs | 1 |
| Analog current output [mA] | 4...20 |
| Max. load [Ω] | 500 |
| Number of digital outputs | 2 |
| Output function | normally open / closed; (configurable) |
| Напряжение питания | 2 |
| Permanent current rating of switching output DC [mA] | 100 |
| Switching frequency DC [Hz] | 0...10000 |
| Display range | -288...288 l/min: -17280...17280 l/h: -14.642...14.642 m/s: -17.28...17.28 m³/h |
| Resolution | 0.1 l/min: 1 l/h: 0.001 m/s: 0.002 m³/h |
| Set point SP | 2.3...240 l/min: 139...14400 l/h: 0.118...12.202 m/s: 0.139...14.4 m³/h |
| Reset point rP | 1.1...238.8 l/min: 64...14325 l/h: 0.055...12.139 m/s: 0.064...14.325 m³/h |
| Analog start point ASP | -240...192 l/min: -14400...11522 l/h: -12.202...9.763 m/s: -14.4...11.522 m³/h |
| Analog end point AEP | -192...240 l/min: -11522...14400 l/h: -9.763...12.202 m/s: -11.522...14.4 m³/h |
| Low flow cut-off LFC | 1...12 l/min: 60...720 l/h: 0.051...0.61 m/s: 0.06...0.72 m³/h |
| Frequency end point, FEP | 48.1...240 l/min: 2889...14400 l/h: 2.448...12.202 m/s: 2.89...14.4 m³/h |
| Frequency at the end point FRP [Hz] | 1...10000 |
| Pulse length [s] | 0.002...2 |
| Pulse value | 0.02...99990000 I |
| Measuring range [°C] | -20...100 |
| Display range [°C] | -44...124 |
| Resolution [°C] | 0.1 |
| Set point SP [°C] | -19.6...100 |
| Reset point rP [°C] | -20...99.6 |
| Analog start point [°C] | -20...76 |
| Analog end point [°C] | 4...100 |
| Frequency start point, FSP [°C] | -20...76 |
| Frequency end point, FEP [°C] | 4...100 |
| Accuracy (in the measuring range) | edible oils: ± (5,0 % MW + 1,0 % MEW); water: ± (1,0 % MW + 0,5 % MEW) |
| Repeatability | ± 0,2 % MEW |
| Accuracy [K] | ± 2,5 (Q > 5 % MEW) |
| Temperature coefficient [% of the span / 10 K] | 0,2 |
| Время отклика | < 0.25; (dAP = 0, T09) |
| Damping process value dAP [s] | 0...5 |
| Dynamic response T05 / T09 [s] | 5,7 / 86 |
| Diagnostic functions | direction of flow detection; signal quality |
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | BLOB: Binary Large Object transfer; Common - I&D: Identification and Diagnosis |
| Required master port class | A |
| Process data analog | 3 |
| Process data binary | 2 |
| Min. process cycle time [ms] | 9.6 |
| IO-Link process data (cyclical) | Function: bit length; totalizer: 32; Flow monitoring: 32; Temperature monitoring: 32; status: 4; Output 1: 1; Output 2: 1 |
| Supported DeviceIDs | Type of operation: DeviceID; default: 1988 |
| Рабочая температура | -20...60 |
| Storage temperature [°C] | -25...80 |
| Protection | IP 69; (DIN EN 60529) |
| EMC | DIN 61326-1:2021 |
| Shock resistance | DIN IEC 68-2-27: 20 g (11ms) |
| Vibration resistance | DIN IEC 68-2-6: 20 g (10...2000Hz) |
| UL approval | UL approval number: I034; File number UL: E174189 |
| Pressure equipment directive | can be used for group 2 fluids; group 1 fluids on request |
| Масса | 1011 |
| Housing | rectangular |
| Inlet pipe length | 5 x DN |
| Outlet pipe length | 1 x DN |
| Dimensions [mm] | 250 x 78 x 87.6 |
| Материал | housing: stainless steel (1.4404 / 316L); Display: PFA; sealing Display: FKM; connector: PBT |
| Материал | Pipe section: stainless steel (1.4435 / 316L); Process connection: stainless steel (1.4404 / 316L) |
| Surface characteristics Ra/Rz of the wetted parts | Ra < 0.4 µm; Rz = 4 µm |
| Display | Color display 1,44", 128 x 128 pixels; Switching function: 2 x LED, yellow; diagnosis: 1 x LED, three-color |
| Remarks | MW = Measured value; MEW = Final value of the measuring range; pulse and totalizer signal are only available for one of the two outputs; the accuracy indications are adhered to over the entire application area; the specified Ra surface characteristics of the wetted surfaces do not apply to the weld seam. |
| Pack quantity | 1 pcs. |
| Connector | 1 x M12; coding: A; Contacts: 4, gold-plated |