TCC551

ifm electronic gmbh TCC551

Temperature transmitter, TCC999K1ER12-A-DKG/US

  • Бренд: ifm electronic gmbh
  • Артикул (MPN): TCC551
  • Статус производства: Не определён

Категории:

Технические характеристики

Number of inputs and outputsNumber of digital outputs: 1; Number of analog outputs: 1
Measuring range-25...160 °C: -13...320 °F
Communication interfaceIO-Link
Process connectionthreaded connection G 1/2 external thread sealing cone
Installation length EL [mm]1000
Special featuregold-plated contacts
Measuring element1 x Pt 1000
Reference element1 x NTC
Installationa thermowell is required for use in hygienic applications
Medialiquids and gases
Pressure rating160 bar: 16 MPa
Minimum installation depth [mm]15
Напряжение питания18...32 DC; (cULus - Class 2 source required)
Current consumption [mA]10; (24 V)
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]6
Integrated watchdogyes
Total number of outputs2
Output signalanalog signal; IO-Link; (calibration check status)
Electrical designPNP/NPN
Number of digital outputs1
Output functionnormally closed; (diagnostic signal)
Напряжение питания2
Permanent current rating of switching output DC [mA]100
Diagnostic outputcalibration check status and error diagnostics
Number of analog outputs1
Analog current output [mA]4...20
Max. load [Ω](Ub - 15 V) x 50
Short-circuit protectionyes
Type of short-circuit protectionyes (non-latching)
Overload protectionyes
Probe length L [mm]1000
Note on measuring rangescalable
Factory setting-10...150 °C / 14...302 °F
Calibration check limit [K]0.5...3
In steps of [K]0.05
Resolution of analog output [K]0.05
Precision analog output [K]± 0,2
Precision IO-Link [K]± 0,2
Temperature coefficient analog output [% of the span / 10 K]< ± 0,02; (In case of deviation from the reference condition 25 ± 5 °C)
Temperature coefficient IO-Link [% of the span / 10 K]< ± 0,01; (In case of deviation from the reference condition 25 ± 5 °C)
Dynamic response T05 / T09 [s]1,5 / 4
Parameter setting optionsDisplay unit; scaling of the analog output; calibration check limit; switching logic diagnostic output; simulation mode
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9 CDV
ProfilesBLOB: Binary Large Object transfer; Common - I&D: Identification and Diagnosis; Function: Measurement data, standard resolution
SIO modeyes
Required master port classA
Process data analog1
Process data binary1
Min. process cycle time [ms]4.4
IO-Link resolution temperature [K]0.01
Supported DeviceIDsType of operation: DeviceID; default: 1129
Рабочая температура-25...70
Рабочая температураmax. internal device temperature: 125 °C
Storage temperature [°C]-40...100
ProtectionIP 68; IP 69K
EMCDIN EN 61000-6-2; DIN EN 61000-6-3
Shock resistanceDIN EN 60068-2-27: 50 g (11 ms)
Vibration resistanceDIN EN 60068-2-6: 35 g (10...2000 Hz)
MTTF [years]329
Масса820
Housingtubular
Dimensions [mm]Ø 50 / L = 1094
Материалstainless steel (1.4404 / 316L); PEI; FKM; PFA
Материалstainless steel (1.4404 / 316L)
Tightening torque [Nm]30...50
Probe diameter [mm]6
RemarksMS = set measuring span; cULus - Class 2 source required
Pack quantity1 pcs.
Connector1 x M12; coding: A; Contacts: 4, gold-plated