ifm electronic gmbh TW2001
Infrared temperature sensor, TW-150KLBM30-KFDKG/US
Технические характеристики
| Number of inputs and outputs | Number of digital outputs: 1; Number of analog outputs: 1 |
|---|---|
| Measuring range | 250...1600 °C: 482...2912 °F |
| Communication interface | IO-Link |
| Application | tempering temperatures; glass melting; graphite; ceramics; metals; forging; sintering; heat treatment; rolling |
| Напряжение питания | 18...32 DC; (to SELV/PELV) |
| Current consumption [mA] | < 50 |
| Min. insulation resistance [MΩ] | 100; (50 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | < 1 |
| Test input | type 3 (IEC 61131-2) |
| Total number of outputs | 2 |
| Output signal | switching signal; analog signal; IO-Link; (configurable) |
| Electrical design | PNP |
| Number of digital outputs | 1 |
| Output function | normally open / closed; (configurable) |
| Напряжение питания | 2.5 |
| Permanent current rating of switching output DC [mA] | 150 |
| Number of analog outputs | 1 |
| Analog current output [mA] | 4...20 |
| Max. load [Ω] | 500 |
| Short-circuit protection | yes |
| Type of short-circuit protection | yes (non-latching) |
| Short-circuit proof | yes |
| Overload protection | yes |
| Wave length range [µm] | 1...1.7 |
| Set point SP | 251...1600 °C: 484...2912 °F |
| Reset point rP | 250...1599 °C: 482...2910 °F |
| Analog start point | 250...1400 °C: 482...2552 °F |
| Analog end point | 450...1600 °C: 842...2912 °F |
| In steps of | 1 °C: 1 °F |
| Resolution of switching output [K] | 1 |
| Resolution of analog output [K] | 0.2; (+ 0.03 % of the set measuring span) |
| Resolution of display [K] | 1 |
| Accuracy [K] | < ± 0,5 %; (of measured value, min. 4 K (degree of emission = 1, T = 23 °C)) |
| Repeatability [K] | 1 |
| Время отклика | 2; (T > 600 °C) |
| Adjustment of the switch point | Programming buttons |
| Parameter setting options | Analog range; normally open / closed; switch-on/switch-off delay; Damping; Peakhold; emissivity; simulation function |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Smart Sensor - SSP 0: Generic Profiled Sensor; Function: Device identification; Function: Process data variable; Function: Device diagnosis |
| SIO mode | yes |
| Required master port class | A |
| Process data analog | 16 |
| Process data binary | 1 |
| Min. process cycle time [ms] | 3.6 |
| Supported DeviceIDs | Type of operation: DeviceID; default: 717 |
| Рабочая температура | 0...65 |
| Storage temperature [°C] | -20...80 |
| Max. relative air humidity [%] | 95; (non condensing) |
| Protection | IP 65 |
| EMC | DIN EN 61000-6-2; DIN EN 61000-6-4 |
| Shock resistance | DIN EN 60068-2-27: 30 g (11 ms) |
| Vibration resistance | DIN EN 60068-2-6: 5 g (10...2000 Hz) |
| MTTF [years] | 74 |
| Масса | 465 |
| Housing | Threaded type |
| Dimensions [mm] | M30 x 1.5 / L = 214 |
| Thread designation | M30 x 1.5 |
| Материал | threaded sleeve: stainless steel (1.4305 / 303); operator interface: polyester |
| Материал | front lens:tempered optical glass |
| Display | Display unit: 2 x LED, yellow; Switching status: 1 x LED, yellow; Function display: 7-segment LED display, 4-digit; Measured values: 7-segment LED display, 4-digit |
| Operating elements | 3: Pushbuttons |
| Items supplied | lock nuts: 2 |
| Remarks | Use a screened cable to protect infrared temperature sensors from interference.; The screen must be connected to the housing of the sensor via the connector. |
| Pack quantity | 1 pcs. |
| Connector | 1 x M12 |