ifm electronic gmbh VVB020
Vibration sensor, VIBRATION IO-LINK SWITCH
Технические характеристики
| Frequency range [Hz] | 2...10000 |
|---|---|
| Measuring principle | capacitive |
| Measuring range of vibration [mm/s] | 0...45 |
| Measuring range of vibration | 1...50 |
| Application | medium-sized machines, power < 300 kW, rotational speed > 600 rpm |
| Напряжение питания | 18...30 DC |
| Current consumption [mA] | < 50 |
| Min. insulation resistance [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Type of sensor | Microelectromechanical system (MEMS) |
| Number of inputs and outputs | Number of digital outputs: 2 |
| Output signal | switching signal; IO-Link |
| Electrical design | PNP/NPN; (configurable) |
| Number of digital outputs | 2 |
| Output function | normally open / closed |
| Напряжение питания | 2 |
| Max. current load per output [mA] | 100 |
| Short-circuit protection | yes |
| Type of short-circuit protection | yes (non-latching) |
| Overload protection | yes |
| Note on setpoint SP | configurable |
| Number of measurement axes | 1 |
| Set point SP [mm/s] | 0.2...45 |
| Reset point rP [mm/s] | 0...44.8 |
| In steps of [mm/s] | 0.2 |
| Set point SP | 2...50 |
| Reset point rP | 1...49 |
| In steps of | 1 |
| Measuring range [°C] | -30...80 |
| Resolution [°C] | 0.1 |
| Set point SP [°C] | -28...80 |
| Reset point rP [°C] | -30...78 |
| In steps of [°C] | 2 |
| Accuracy | ≤ 4 kHz +/-10 %; ≥ 4...10 kHz: < 3 dB |
| Accuracy [K] | ± 2,5 K + (0,2 x (Umgebungstemperatur - Oberflächentemperatur)) |
| Linearity deviation | 2 % |
| Parameter setting options | Software |
| Diagnostic functions | self-test |
| Communication interface | IO-Link |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9: 2013-07 |
| Profiles | BLOB: Binary Large Object transfer; Common - I&D: Identification and Diagnosis; Function: Measurement data, standard resolution |
| SIO mode | yes |
| Required master port class | A |
| Process data analog | 10 |
| Process data binary | 2 |
| IO-Link functions (acyclical) | filter for v-RMS, a-RMS, a-Peak; Hysteresis; window; Switch points; switching logic |
| Supported DeviceIDs | Type of operation: DeviceID; Status A (COM2): 1257; Status B (COM2 / COM3): 1369 |
| Note | For further information please see the IODD PDF file at "Downloads" |
| Transmission type | COM3 (230,4 kBaud) |
| Min. process cycle time [ms] | 3.6 |
| Рабочая температура | -30...80 |
| Storage temperature [°C] | -30...80 |
| Protection | IP 67; IP 68; IP 69K |
| EMC | 2014/30/EU; DIN EN 61000-6-2; DIN EN 61000-6-3 |
| Shock resistance | DIN EN 60068-2-27: 50 g 11 ms; 500 g 1 ms |
| Vibration resistance | DIN EN 60068-2-6: 20 g / 10...3000 Hz |
| MTTF [years] | 299 |
| UL approval | Ta: -30...60 °C; UL approval number: L002 |
| Масса | 116.5 |
| Housing | tubular |
| Type of mounting | set screw |
| Dimensions [mm] | Ø 22 / L = 63.55 |
| Материал | housing: stainless steel (1.4404 / 316L) |
| Tightening torque [Nm] | 8 |
| Items supplied | set screw: 1 x (1/4" 28 UNF / M8); set screw: 1 x (1/4"28 UNF x 5/8" DIN916) |
| Notes | the hardware version BC has a temporarily changed ambient temperature range |
| Pack quantity | 1 pcs. |
| Connector | 1 x M12; coding: A; Contacts: 4; Maximum cable length: 20 m |