K.A. Schmersal GmbH & Co. KG AZM190-02/01RK-230VAC
AZM190-02/01RK-230VAC
Технические характеристики
| Predecessor part number | 101182119 |
|---|---|
| Article number (order number) | 131182119 |
| EAN (European Article Number) | 8905236102271 |
| eCl@ss number, version 12.0 | 27-27-26-03 |
| eCl@ss number, version 11.0 | 27-27-26-03 |
| eCl@ss number, version 9.0 | 27-27-26-03 |
| ETIM number, version 7.0 | EC002593 |
| ETIM number, version 6.0 | EC002593 |
| Сертификация | CCC cULus |
| Standards | BG-GS-ET-19 EN IEC 60947-5-1 EN ISO 13849-1 EN ISO 14119 |
| Coding level according to EN ISO 14119 | Low |
| Working principle | electromechanical |
| Материал | Glass-fibre, reinforced thermoplastic |
| Масса | 480 g |
| Power to unlock | Yes |
| Manual release | Yes |
| Number of actuating directions | 4 |
| Number of safety contacts | 3 |
| Number of cable glands | 2 |
| Safety classification - Standards | EN ISO 13849-1 |
| Performance Level, up to | c |
| Category | 1 |
| B 10D Normally-closed contact (NC) | 2,000,000 Operations |
| Note | Electrical life on request. |
| B 10D Normally-open contact (NO) | 1,000,000 Operations |
| Safety classification - Note | at 10% I e and ohmic load |
| Mission time | 20 Year(s) |
| Please note: | Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed. |
| Safety classification - Fault exclusion - Performance Level, up to | d |
| Safety classification - Fault exclusion - Category | 3 |
| Safety classification - Fault exclusion - Note | for 2-channel use and with suitable logic unit. |
| Safety classification - Fault exclusion - Mission time | 20 Year(s) |
| Safety classification - Guard locking function - Performance Level, up to | e |
| Note (Performance Level) | Information for the safety classification of the guard locking function is documented in the "Operating instructions" or in the "Operation and mounting" instructions. |
| Mechanical lifetime, minimum | 1,000,000 Operations |
| Holding force F Zh in accordance with EN ISO 14119 | 1,950 N |
| Holding force F max , maximum | 2,550 N |
| Latching force | 20 N |
| Positive break force, minimum | 20 N |
| Actuating speed, maximum | 0.3 m/s |
| Mounting | Screws |
| Type of the fixing screws | 2x M5 |
| Cable entry | 2 x M20 x 1,5 |
| Termination | Screw terminals |
| Cable section, minimum | 0.5 mm² |
| Cable section, maximum | 1.5 mm² |
| Mechanical data - Connection technique - Note | All indications including the conductor ferrules. |
| Tightening torque of electrical connection, minimum | 0.5 Nm |
| Tightening torque of electrical connection, maximum | 0.6 Nm |
| Tool for the connection | SL / PH 2 |
| Strip length | 6 mm |
| Length of sensor | 41 mm |
| Width of sensor | 52 mm |
| Height of sensor | 178 mm |
| IP Degree of protection | IP65 IP67 |
| Рабочая температура | -25 ... +55 °C |
| Note (Relative humidity) | non-condensing non-icing |
| Protection class | II |
| Напряжение питания | 250 VAC |
| Напряжение питания | 4 kV |
| Thermal test current | 4 A |
| Напряжение питания | 230 VAC |
| Required rated short-circuit current | 1,000 A |
| Electrical power consumption, maximum | 8.5 W |
| Switching element | Magnet: 2 NC contacts / Actuator: 1 NC contact |
| Switching principle | slow action, positive break NC contact |
| Maximum switching frequency | 1,200 /h |
| Материал | Silver |
| Magnet switch-on time | 100 % |
| Test pulse duration, maximum | 5 ms |
| Test pulse interval, minimum | 50 ms |
| Напряжение питания | 230 VAC |
| Current, Utilisation category AC-15 | 4 A |
| Напряжение питания | 24 VDC |
| Current, Utilisation category DC-13 | 4 A |
| Напряжение питания | 230 VAC |
| Electrical data - Auxiliary contacts - Current, Utilisation category AC-15 | 4 A |
| Напряжение питания | 24 VDC |
| Electrical data - Auxiliary contacts - Current, Utilisation category DC-13 | 4 A |
| Note (applications) | hinged safety guard removable guard sliding safety guard |
| Scope of delivery | Actuator must be ordered separately. |
| Note (Manual release) | For maintenance, installation, etc. front |