K.A. Schmersal GmbH & Co. KG MZM-100-B-ST-1P2PW2RE-A
MZM 100 B ST-1P2PW2RE-A
Технические характеристики
| Article number (order number) | 101211068 |
|---|---|
| EAN (European Article Number) | 4030661389103 |
| eCl@ss number, version 12.0 | 27-27-26-03 |
| eCl@ss number, version 11.0 | 27-27-26-03 |
| eCl@ss number, version 9.0 | 27-27-26-03 |
| ETIM number, version 7.0 | EC002593 |
| ETIM number, version 6.0 | EC002593 |
| Сертификация | cULus TÜV |
| Standards | EN IEC 60947-5-3 EN IEC 61508 EN ISO 13849-1 EN ISO 14119 |
| Coding | Universal coding |
| Coding level according to EN ISO 14119 | Low |
| Working principle | inductive |
| Материал | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
| Reaction time, maximum | 150 ms |
| Duration of risk, maximum | 150 ms |
| Масса | 645 g |
| Power to lock | Yes |
| Actuator monitored | Yes |
| Latching | Yes |
| Short circuit detection | Yes |
| Cross-circuit detection | Yes |
| Series-wiring | Yes |
| Safety functions | Yes |
| Integral system diagnostics, status | Yes |
| Number of digital fail-safe inputs | 2 |
| Number of fail-safe digital outputs | 2 |
| Safety classification - Standards | EN IEC 61508 EN ISO 13849-1 |
| Performance Level, up to | e |
| Category | 4 |
| PFH value | 3.54 x 10⁻⁹ /h |
| Safety Integrity Level (SIL), suitable for applications in | 3 |
| Mission time | 20 Year(s) |
| Mechanical lifetime, minimum | 1,000,000 Operations |
| Note (Mechanical lifetime) | Actuating speed ≤ 0.5 m/s Operations for door weights ≤ 5 kg |
| Angular misalignment between solenoid interlock and actuator, maximum | 2 ° |
| Minimum distance devices | 100 mm |
| Holding force, typically | 750 N |
| Holding force, guaranteed | 500 N |
| Latching force, minimum | 30 N |
| Latching force, maximum | 100 N |
| Type of the fixing screws | 2x M6 |
| Tightening torque of the fixing screws | 8 Nm |
| Assured switching distance "ON" S ao | 0 mm |
| Assured switching distance "OFF" S ar | 1 mm |
| Note (switching distance) | All switching distances in accordance EN IEC 60947-5-3 |
| Length of sensor chain, maximum | 200 m |
| Note (length of the sensor chain) | Cable length and cross-section change the voltage drop dependiing on the output current |
| Note (series-wiring) | Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD |
| Termination | Connector M23, 8+1-pole |
| Length of sensor | 40 mm |
| Width of sensor | 40 mm |
| Height of sensor | 179 mm |
| IP Degree of protection | IP65 IP67 |
| Рабочая температура | -25 ... +55 °C |
| Storage and transport temperature | -25 ... +70 °C |
| Relative humidity, minimum | 30 % |
| Relative humidity, maximum | 95 % |
| Note (Relative humidity) | non-condensing non-icing |
| Resistance to vibrations | 10 … 150 Hz, amplitude 0.35 mm / 5 g |
| Restistance to shock | 30 g / 11 ms |
| Protection class | III |
| Permissible installation altitude above sea level, maximum | 2,000 m |
| Напряжение питания | 32 VDC |
| Напряжение питания | 0.8 kV |
| Напряжение питания | III |
| Degree of pollution | 3 |
| Напряжение питания | 24 VDC -15 % / +10 % (stabilised PELV power supply) |
| No-load supply current I 0 , typical | 100 mA |
| Current consumption with magnet ON, average | 350 mA |
| Current consumption with magnet ON, peak | 550 mA / 10 ms |
| Напряжение питания | 24 VDC |
| Operating current | 1,100 mA |
| Required rated short-circuit current | 100 A |
| External wire and device fuse rating | 2 A gG |
| Time to readiness, maximum | 4,000 ms |
| Switching frequency, maximum | 1 Hz |
| Designation, Magnet control | IN |
| Switching thresholds | -3 V … 5 V (Low) 15 V … 30 V (High) |
| Current consumption at 24 V | 10 mA |
| Magnet switch-on time | 100 % |
| Test pulse duration, maximum | 5 ms |
| Test pulse interval, minimum | 40 ms |
| Classification ZVEI CB24I, Sink | C0 |
| Classification ZVEI CB24I, Source | C1 C2 C3 |
| Designation, Safety inputs | X1 and X2 |
| Electrical data - Safety digital inputs - Switching thresholds | −3 V … 5 V (Low) 15 V … 30 V (High) |
| Electrical data - Safety digital inputs - Current consumption at 24 V | 5 mA |
| Electrical data - Safety digital inputs - Test pulse duration, maximum | 1 ms |
| Electrical data - Safety digital inputs - Test pulse interval, minimum | 100 ms |
| Electrical data - Safety digital inputs - Classification ZVEI CB24I, Sink | C1 |
| Electrical data - Safety digital inputs - Classification ZVEI CB24I, Source | C1 C2 C3 |
| Designation, Safety outputs | Y1 and Y2 |
| Rated operating current (safety outputs) | 250 mA |
| Design of control elements | short-circuit proof, p-type |
| Напряжение питания | 1 V |
| Leakage current I r , maximum | 0.5 mA |
| Напряжение питания | 24 VDC |
| Current, Utilisation category DC-13 | 0.25 A |
| Test pulse interval, typical | 1,000 ms |
| Electrical data - Safety digital outputs - Test pulse duration, maximum | 1 ms |
| Electrical data - Safety digital outputs - Classification ZVEI CB24I, Source | C1 |
| Electrical data - Safety digital outputs - Classification ZVEI CB24I, Sink | C1 |
| Designation, Diagnostic outputs | OUT |
| Напряжение питания | 24 VDC |
| Electrical data - Diagnostic outputs - Operating current | 50 mA |
| Electrical data - Diagnostic outputs - Design of control elements | short-circuit proof, p-type |
| Напряжение питания | 2 V |
| Напряжение питания | 24 VDC |
| Electrical data - Diagnostic outputs - Current, Utilisation category DC-13 | 0.05 A |
| Note (LED switching conditions display) | Error / functional defect: LED red Operating condition: LED green Supply voltage UB: LED green |
| PIN 1 | A1 Supply voltage UB |
| PIN 2 | X1 Safety input 1 |
| PIN 3 | A2 GND |
| PIN 4 | Y1 Safety output 1 |
| PIN 5 | OUT Diagnostic output |
| PIN 6 | X2 Safety input 2 |
| PIN 7 | Y2 Safety output 2 |
| PIN 8 | IN Solenoid control |
| PIN 9 | without function |
| Scope of delivery | Actuator must be ordered separately. |
| Recommendation (actuator) | MZM 100-B1.1 |
| Note (General) | As long as the actuating unit is applied to the solenoid interlock, the unlocked safety guard can be relocked. In this case, the safety outputs are re-enabled, so that the safety guard must not be opened. |