K.A. Schmersal GmbH & Co. KG SRB201LC
SRB201LC
Технические характеристики
| Article number (order number) | 101212555 |
|---|---|
| EAN (European Article Number) | 4030661448916 |
| eCl@ss number, version 12.0 | 27-37-18-19 |
| eCl@ss number, version 11.0 | 27-37-18-19 |
| eCl@ss number, version 9.0 | 27-37-18-19 |
| ETIM number, version 7.0 | EC001449 |
| ETIM number, version 6.0 | EC001449 |
| Notice | Discontinued product |
| Сертификация | cULus TÜV |
| Standards | EN IEC 60204-1 EN IEC 60947-1 EN IEC 60947-5-1 EN IEC 60947-5-3 EN IEC 60947-5-5 EN IEC 61508 EN IEC 62061 EN ISO 13849-1 |
| Climatic stress | EN 60068-2-78 |
| Материал | Glass-fibre reinforced thermoplastic, ventilated |
| Масса | 200 g |
| Wire breakage detection | Yes |
| Feedback circuit | Yes |
| Automatic reset function | Yes |
| Earth connection detection | Yes |
| Integral system diagnostics, status | Yes |
| Number of LEDs | 3 |
| Number of normally closed (NC) | 2 |
| Number of undelayed semi-conductor outputs with signaling function | 1 |
| Number of safety contacts | 2 |
| Number of signalling outputs | 1 |
| Safety classification - Standards | EN IEC 60947-5-1 EN IEC 61508 |
| Stop-Category | 0 1 |
| Performance Level, stop 0, up to | e |
| Category, Stop 0 | 4 |
| Diagnostic Coverage (DC) Level, Stop 0 | ≥ 99 % |
| PFH value, Stop 0 | 2.00 x 10⁻⁸ /h |
| Safety Integrity Level (SIL), Stop 0, suitable for applications in | 3 |
| Mission time | 20 Year(s) |
| Common Cause Failure (CCF), minimum | 65 |
| Mechanical lifetime, minimum | 10,000,000 Operations |
| Mounting | Snaps onto standard DIN rail to EN 60715 |
| Terminal designations | IEC/EN 60947-1 |
| Cable section, minimum | 0.25 mm² |
| Cable section, maximum | 2.5 mm² |
| Tightening torque of Clips | 0.6 Nm |
| Allowed type of cable | flexible solid single-wire |
| Terminal (mechanical) | Screw terminals |
| Width | 22.5 mm |
| Height | 100 mm |
| Depth | 121 mm |
| IP Degree of protection of the enclosure | IP40 |
| IP Degree of protection of the installation space | IP54 |
| IP Degree of protection of clips or terminals | IP20 |
| Рабочая температура | -25 ... +60 °C |
| Storage and transport temperature | -40 ... +85 °C |
| Resistance to vibrations | 10...55 Hz, Amplitude 0.35 mm, ± 15 % |
| Restistance to shock | 10 g / 11 ms |
| Напряжение питания | 4 kV |
| Напряжение питания | III |
| Degree of pollution | 2 |
| Frequency range | 50 Hz 60 Hz |
| Напряжение питания | 24 VAC -15 % / +10 % 24 VDC -15 % / +20 % |
| Напряжение питания | 10 % |
| Напряжение питания | 24 VAC |
| Напряжение питания | 24 VDC |
| Напряжение питания | 20.4 VAC |
| Напряжение питания | 26.4 VAC |
| Напряжение питания | 20.4 VAC |
| Напряжение питания | 26.4 VAC |
| Напряжение питания | 20.4 VDC |
| Напряжение питания | 28.8 VDC |
| Electrical power consumption | 2 W |
| Electrical data - Electrical power consumption | 5.2 VA |
| Contact resistance, maximum | 0.1 Ω |
| Note (Contact resistance) | in new state |
| Drop-out delay in case of power failure, typically | 80 ms |
| Drop-out delay in case of emergency, typically | 20 ms |
| Pull-in delay at automatic start, maximum, typically | 100 ms |
| Pull-in delay at RESET, typically | 20 ms |
| Материал | AgSn0. self-cleaning, positive drive |
| Напряжение питания | 230 VAC |
| Current, Utilisation category AC-15 | 6 A |
| Напряжение питания | 24 VDC |
| Current, Utilisation category DC-13 | 6 A |
| Switching capacity, minimum | 10 VDC |
| Electrical data - Safe relay outputs - Switching capacity, minimum | 10 mA |
| Switching capacity, maximum | 250 VAC |
| Electrical data - Safe relay outputs - Switching capacity, maximum | 8 A |
| Conduction resistance, maximum | 40 Ω |
| Electrical data - Relay outputs (auxiliary contacts) - Switching capacity, maximum | 2 A |
| EMC rating | EMC-Directive |
| Indicated operating states | Internal operating voltage U i Position relay K1 Position relay K2 |
| Note (applications) | Emergency-Stop button Guard system Pull-wire emergency stop switches Safety light curtain |
| Note (General) | Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit. |
| Note (Wiring diagram) | Automatic start: The automatic start is programmed by connecting the feedback circuit to the terminals X1/X2. If the feedback circuit is not required, establish a bridge. In case of a 1-channel control, connect the NC contact to the operating voltage and bridge S11/S12 and S21/S22. Input level: The example shows a 2-channel control of a guard door monitoring with two position switches, whereof one with positive break, external reset button (R); cross-wire monitoring and feedback circuit (H2) Relay outputs: Suitable for 2 channel control, for increase in capacity or number of contacts by means of contactors or relays with positive-guided contacts. The control recognises cross-short, cable break and earth leakages in the monitoring circuit. The wiring diagram is shown with guard doors closed and in de-energised condition. |