KE
KEYENCE CORPORATION IX-055
IX series (Image-Based Laser Sensor) - IX-055
Категории:
Технические характеристики
| Reference distance | 55 mm 2.17" |
|---|---|
| Measuring distance | 45 to 65 mm 1.77" to 2.56" |
| Detection area (Scan mode) | Measuring distance of 45 mm 1.77" : 27.5 × 20.5 mm 1.08" × 0.81" Measuring distance of 55 mm 2.17" : 32.5 × 24.5 mm 1.28" × 0.96" Measuring distance of 65 mm 2.56" : 37.5 × 28.5 mm 1.48" × 1.12" (X direction) × (Y direction) |
| Detection area (Line mode) | Measuring distance of 45 mm 1.77" : 27.5 mm 1.08" Measuring distance of 55 mm 2.17" : 32.5 mm 1.28" Measuring distance of 65 mm 2.56" : 37.5 mm 1.48" (X direction) |
| Laser Light source (Light source) | 660 nm (visible light) wavelength red semiconductor laser |
| Laser Light source (Laser class) | Class II laser product (FDA [CDRH] Part 1040.10), Class 2 laser product (IEC 60825-1: 2014) |
| Laser Light source (Output) | 0.95 mW (FDA [CDRH] Part 1040.10), 1.6 mW (IEC 60825-1: 2014) |
| Height(Z direction) (Minimum detectable object size) | ø0.7 mm ø0.0276"; ø0.4 mm ø0.0157"; ø0.3 mm ø0.0118"; 0.5 mm × 0.5 mm 0.0197" × 0.0197" |
| Height(Z direction) (Repeatability) | 10 μm |
| Width(X direction) (Minimum edge detection) | 0.3 mm 0.0118" |
| Estimated detection | (When measuring the height between two points, the minimum step difference is as follows. IX-055: 100 μm / IX-080: 200 μm / IX-150: 500 μm / IX-360: 1000 μm / IX-360W: 1000 μm) |
| Sampling cycle (Scan mode) | 120 ms (min.) (typical) |
| Sampling cycle (Line mode) | 6 ms / 11 ms (selectable) |
| Image receiving element | Monochrome CMOS image sensor |
| Image capture lighting (Light source) | Red LED |
| Image capture lighting (Lighting method) | Pulse lighting |
| Temperature characteristics | 0.04% of F.S./°C |
| Степень защиты (IP) | IP67 |
| Environmental resistance (Ambient light) | Incandescent lamp, 5000 lux or less |
| Рабочая температура | 0 to +45°C 32 to 113°F (No freezing) |
| Environmental resistance (Relative humidity) | 35 to 85% RH (No condensation) |
| Environmental resistance (Vibration resistance) | 10 to 55 Hz; double amplitude 1.5 mm 0.06" ; 2 hours in each of the X, Y, and Z directions |
| Environmental resistance (Shock resistance) | 500 m/s 2 1640' /s 2 , 3 times in each of the 3 directions |
| Материал | Main unit case: Zinc die-casting / Front cover: Glass, acrylic (hard coat) / Operation indicator cover: TPU / Connector ring: PBT / Connector: Zinc die-casting |
| Масса | Approx. 190 g |