Технические характеристики

Main unit / expansion unitMain unit
Display (Min. display unit)10 µm
Display (Display range)±999.99 to ±999 mm (with 4 selectable steps)
Tools (Scan mode)Height, Height difference, Max./Min., Height difference calculation, Thickness calculation, Height detection, Monochromatic detection, Position adjustment (Max. number of settings) Detection: 16 tools, Position adjustment: 1 tool
Tools (Line mode)Height (Ave./Max./Min.) , Height difference (Ave./Max./Min.) , Height difference calculation, Thickness calculation, Position adjustment, Tilt correction (Max. number of settings) Detection: 16 tools, Position adjustment: 1 tool, Alignment adjustment: 1 tool
Other functions (Common)ZERO/offset, Operating threshold adjustment, 2-point calibration, Measurement direction, Position correction NG measurement, Zero/offset recording,Capture mode (HDR) Sensor date/time Information addition, N.O./N.C. switching, I/O monitor, Automatic brightness adjustment, Lighting (ON/OFF) , Total judgment conditions,NPN/PNP switching, Simultaneous main unit/expansion unit input, Light interference prevention, Security
Other functions (Scan mode)Measurement range, Measurement position (small/standard/large) , Measurement mode, Measurement noise elimination, Imaging mode (high gain) , Tilt correction (fixed or real-time correction) , Glare removal, Trigger input (internal/external) , Trigger interval, Trigger delay, Trigger error, Monochrome histogram, Fixed reference area, Mask outline, Rotation range
Other functions (Line mode)Average count, Laser position adjustment, Timing input, Head tilt correction (fixed only), Ambient light removal for measurement, HOLD function, Alarm setting, Measurement method (Ave./Max./Min.)
Input (Input)Non-voltage input/voltage input is switchable For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit) For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V)
Input (Number of inputs)8 (IN1 to IN8)
Input (Function)IN1: External trigger up/down timing, IN2 to IN8: Enable by assigning optional functions Assignable functions: Program switching, Laser emission stop, Zero/offset (batch) , Reset (error only) , Reset (judgment value only) Reset (judgment value and error)
Output (Output)Open collector output; NPN/PNP switchable, N.O./N.C. switchable For open collector NPN output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit) , residual voltage of 1.5 V or less For open collector PNP output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit) , residual voltage of 2 V or less
Output (Number of inputs)10 (OUT1 to OUT10)
Output (Function)Enable by assigning the optional functions Assignable functions: Total judgment result (All OK, Any OK/NG) , run, busy, error, position adjustment result, tilt correction result, Monochromatic detection/Height detection tool result (OK/NG) , Height/height difference/Max./Min./calculation tool result (OK/NG/HIGH/LO) , Alarm
Напряжение питания±5 V, 1 to 5 V, 0 to 5 V, Output impedance: 100 Ω
Analog current output4 to 20 mA, max. load resistance: 350 Ω
Number of programs32
Statistical informationScan mode: Measured value / Degree of similarity (Max., Min., Ave.), Processing time (Latest, Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers) Line mode: Measured value / Degree of similarity (Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers)
Detection record (Number of storage)80 images (FTP/SFTP Client function: Enable) 100 images (FTP/SFTP Client function: Disable); 400 images (FTP/SFTP Client function: Enable) 500 images (FTP/SFTP Client function: Disable)
Detection history (Save conditions)NG only/All is selectable
FTP/SFTP data transfer (FTP/SFTP client function) (Transfer Destination)FTP/SFTP server
FTP/SFTP data transfer (FTP/SFTP client function) (Transfer format)bmp/jpeg/txt is selectable
FTP/SFTP data transfer (FTP/SFTP client function) (Transfer Condition)4 conditions All / Total status result (OK/NG) / Result for each tool (OK/(NG and ALM)) is selectable
Ethernet (Standard)100BASE-TX/10BASE-T
Ethernet (Connector)RJ45 8-pin connector
Interface compatibilityCC-Link / DeviceNet® / EtherNet/IP™ / EtherCAT Ⓡ / RS-232C / BCD / PROFINET / PROFIBUS / TCP/IP output
Number of connectible unitsMain units: 1, Expansion units: 1, Communication units (DL) : 1
Напряжение питания24 VDC ±10 % (including ripple)
Ratings (Current consumption)Max. 1.9 A or less (With main unit only: 0.8 A or less, With unit expansion: 1.9 A or less) (Excluding output load)
Рабочая температура0 to +50°C 32 to 122°F (No freezing)
Environmental resistance (Relative humidity)35 to 85 % RH (No condensation)
МатериалMain unit case: PC/Power connector: PA, POM/Analog output connector: PA, POM/I/O connector: PA/ Head connector: Zinc + Ni plating, PA/Ethernet connector: Copper alloy + Ni plating/ Rear heat sink: Aluminum/Main unit rear DIN rail fixing tab: POM/Nameplate: PC
МассаApprox. 210 g