KE
KEYENCE CORPORATION IX-H2000
IX series (Image-Based Laser Sensor) - IX-H2000
Категории:
Технические характеристики
| Main unit / expansion unit | Main unit |
|---|---|
| Display (Min. display unit) | 10 μm; 50 μm |
| Display (Display range) | ±999.99 to ±999 mm 39.33" (with 4 selectable steps); ±999.95 to ±999 mm 39.33" (with 4 selectable steps) |
| Tools (Scan mode) | Height, Step, Average height, Pin height, MAX/MIN, Height area, Monochrome area, Width, Step calculation, Thickness calculation, Position adjustment, 1-axis adjustment, 2-axis adjustment (Max. number of settings) Judgment: 16 tools, Position adjustment: 1 tool |
| Tools (Line mode) | Height (Ave./Max./Min.), Step (Ave./Max./Min.), Edge position, Width/diameter, Step/width calculation, Thickness calculation, Position adjustment, Tilt adjustment (Max. number of settings) Judgment: 16 tools , Position adjustment: 1 tool, Tilt adjustment: 1 tool |
| Other functions (Common) | Zero/offset, Operating threshold adjustment, 2-point calibration, Measurement direction, Position correction NG measurement, Zero/offset recording, Capture mode (HDR), Sensor date/time information addition, N.O./N.C. switching, I/O monitor, Automatic brightness adjustment, Lighting (ON/OFF), Total judgment conditions, NPN/PNP switching, Simultaneous main unit/expansion unit input, Mutual interference prevention, Security |
| Other functions (Scan mode) | Measurement range, Measurement position (small/standard/large), Measurement mode, Measurement noise elimination, Imaging mode (high gain), Tilt correction (fixed or real-time correction), Glare removal, Trigger input (internal/external), Trigger interval, Trigger delay, Trigger error, Monochrome histogram, Area height histogram, Fixed reference area, Mask outline, Rotation range, Height image display on tool setting screen, Scaling function |
| Other functions (Line mode) | Average count, Laser position adjustment, Timing input, Head tilt correction (fixed only), Ambient light removal for measurement, HOLD function, Alarm setting, Measurement method (Ave./Max./Min.), Laser sensitivity adjustment, Averaging filter, Median filter, X-axis median filter |
| Input (Input) | Switchable between non-voltage input and voltage input For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit) For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V) |
| Input (Number of inputs) | 8 (IN1 to IN8) |
| Input (Function) | IN1: External trigger ↑↓ / Timing input, IN2 to IN8: Enable by assigning optional functions Assignable functions: Program switching, Laser emission stop, Zero/offset (batch), Reset (error only), Reset (judgment value only) Reset (judgment value and error) |
| Output (Output) | Open collector output; NPN/PNP switchable, N.O./N.C. switchable For open collector NPN output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit), residual voltage of 1.5 V or less For open collector PNP output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit), residual voltage of 2 V or less |
| Output (Number of inputs) | 10 (OUT1 to OUT10) |
| Output (Function) | Enable by assigning the optional functions Assignable functions: Total judgment result (All OK/Any OK/NG), Run, Busy, Error, Position adjustment result, Tilt adjustment result, Result of the logical operation of each tool, Monochrome area / Height area tool result (OK/NG), Height / Step / Max./Min. / Calculation tool result (OK/NG/HIGH/LO), Alarm |
| Напряжение питания | ±5 V, 1 to 5 V, 0 to 5 V, Output impedance: 100 Ω |
| Analog current output | 4 to 20 mA, Max. load resistance: 350 Ω |
| Number of programs | 32 |
| Statistical information | Scan mode: Measured value / Degree of similarity (Max., Min., Ave.), Processing time (Latest, Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers) Line mode: Measured value / Degree of similarity (Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers) |
| Detection history (Saved history) | 50 (FTP/SFTP client function: Enabled/High-resolution mode: Enabled) 80 (FTP/SFTP client function: Enabled/High-resolution mode: Disabled) 70 (FTP/SFTP client function: Disabled/High-resolution mode: Enabled) 100 (FTP/SFTP client function: Disabled/High-resolution mode: Disabled); 400 (FTP/SFTP client function: Enabled/High-resolution mode: -) 500 (FTP/SFTP client function: Disabled/High-resolution mode: -) |
| Detection history (Save conditions) | Selectable between NG only and All |
| Image data transmission (FTP/SFTP client function) (Destination) | FTP/SFTP server |
| Image data transmission (FTP/SFTP client function) (Method) | Selectable between bmp, jpeg, and txt |
| Image data transmission (FTP/SFTP client function) (Conditions) | 4 conditions Selectable between All, Total judgment result (OK/NG), Result of each tool (OK/(NG and ALM)), and Result of the logical operation of each tool (OK/NG) |
| Ethernet (Standard) | 100BASE-TX/10BASE-T |
| Ethernet (Connector) | RJ45 8-pin connector |
| Interface compatibility | CC-Link, DeviceNet®, EtherNet/IP™, EtherCAT®, RS-232C, BCD output, TCP/IP non-procedural communication |
| Number of connectible units | Main units: 1, Expansion units: 1, Communication units (DL): 1 |
| Напряжение питания | 24 VDC ±10% (including ripple) |
| Ratings (Current consumption) | Max. 1.9 A or less (With main unit only: 0.8 A or less, With unit expansion: 1.9 A or less) (Excluding output load) |
| Рабочая температура | 0 to +50°C 32 to 122°F (No freezing) |
| Environmental resistance (Relative humidity) | 35 to 85% RH (No condensation) |
| Материал | Main unit case: PC / Power connector: PA, POM / Analog output connector: PA, POM / I/O connector: PA / Head connector: Zinc + Ni plating, PA / Ethernet connector: Copper alloy + Ni plating / Rear heat sink: Aluminum / Main unit rear DIN rail fixing tab: POM / Nameplate: PC |
| Масса | Approx. 210 g |