KE

KEYENCE CORPORATION IX-H2000

IX series (Image-Based Laser Sensor) - IX-H2000

  • Бренд: KEYENCE CORPORATION
  • Артикул (MPN): IX-H2000
  • Серия: IX Series
  • Статус производства: В производстве

Категории:

Технические характеристики

Main unit / expansion unitMain unit
Display (Min. display unit)10 μm; 50 μm
Display (Display range)±999.99 to ±999 mm 39.33" (with 4 selectable steps); ±999.95 to ±999 mm 39.33" (with 4 selectable steps)
Tools (Scan mode)Height, Step, Average height, Pin height, MAX/MIN, Height area, Monochrome area, Width, Step calculation, Thickness calculation, Position adjustment, 1-axis adjustment, 2-axis adjustment (Max. number of settings) Judgment: 16 tools, Position adjustment: 1 tool
Tools (Line mode)Height (Ave./Max./Min.), Step (Ave./Max./Min.), Edge position, Width/diameter, Step/width calculation, Thickness calculation, Position adjustment, Tilt adjustment (Max. number of settings) Judgment: 16 tools , Position adjustment: 1 tool, Tilt adjustment: 1 tool
Other functions (Common)Zero/offset, Operating threshold adjustment, 2-point calibration, Measurement direction, Position correction NG measurement, Zero/offset recording, Capture mode (HDR), Sensor date/time information addition, N.O./N.C. switching, I/O monitor, Automatic brightness adjustment, Lighting (ON/OFF), Total judgment conditions, NPN/PNP switching, Simultaneous main unit/expansion unit input, Mutual interference prevention, Security
Other functions (Scan mode)Measurement range, Measurement position (small/standard/large), Measurement mode, Measurement noise elimination, Imaging mode (high gain), Tilt correction (fixed or real-time correction), Glare removal, Trigger input (internal/external), Trigger interval, Trigger delay, Trigger error, Monochrome histogram, Area height histogram, Fixed reference area, Mask outline, Rotation range, Height image display on tool setting screen, Scaling function
Other functions (Line mode)Average count, Laser position adjustment, Timing input, Head tilt correction (fixed only), Ambient light removal for measurement, HOLD function, Alarm setting, Measurement method (Ave./Max./Min.), Laser sensitivity adjustment, Averaging filter, Median filter, X-axis median filter
Input (Input)Switchable between non-voltage input and voltage input For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit) For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V)
Input (Number of inputs)8 (IN1 to IN8)
Input (Function)IN1: External trigger ↑↓ / Timing input, IN2 to IN8: Enable by assigning optional functions Assignable functions: Program switching, Laser emission stop, Zero/offset (batch), Reset (error only), Reset (judgment value only) Reset (judgment value and error)
Output (Output)Open collector output; NPN/PNP switchable, N.O./N.C. switchable For open collector NPN output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit), residual voltage of 1.5 V or less For open collector PNP output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit), residual voltage of 2 V or less
Output (Number of inputs)10 (OUT1 to OUT10)
Output (Function)Enable by assigning the optional functions Assignable functions: Total judgment result (All OK/Any OK/NG), Run, Busy, Error, Position adjustment result, Tilt adjustment result, Result of the logical operation of each tool, Monochrome area / Height area tool result (OK/NG), Height / Step / Max./Min. / Calculation tool result (OK/NG/HIGH/LO), Alarm
Напряжение питания±5 V, 1 to 5 V, 0 to 5 V, Output impedance: 100 Ω
Analog current output4 to 20 mA, Max. load resistance: 350 Ω
Number of programs32
Statistical informationScan mode: Measured value / Degree of similarity (Max., Min., Ave.), Processing time (Latest, Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers) Line mode: Measured value / Degree of similarity (Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers)
Detection history (Saved history)50 (FTP/SFTP client function: Enabled/High-resolution mode: Enabled) 80 (FTP/SFTP client function: Enabled/High-resolution mode: Disabled) 70 (FTP/SFTP client function: Disabled/High-resolution mode: Enabled) 100 (FTP/SFTP client function: Disabled/High-resolution mode: Disabled); 400 (FTP/SFTP client function: Enabled/High-resolution mode: -) 500 (FTP/SFTP client function: Disabled/High-resolution mode: -)
Detection history (Save conditions)Selectable between NG only and All
Image data transmission (FTP/SFTP client function) (Destination)FTP/SFTP server
Image data transmission (FTP/SFTP client function) (Method)Selectable between bmp, jpeg, and txt
Image data transmission (FTP/SFTP client function) (Conditions)4 conditions Selectable between All, Total judgment result (OK/NG), Result of each tool (OK/(NG and ALM)), and Result of the logical operation of each tool (OK/NG)
Ethernet (Standard)100BASE-TX/10BASE-T
Ethernet (Connector)RJ45 8-pin connector
Interface compatibilityCC-Link, DeviceNet®, EtherNet/IP™, EtherCAT®, RS-232C, BCD output, TCP/IP non-procedural communication
Number of connectible unitsMain units: 1, Expansion units: 1, Communication units (DL): 1
Напряжение питания24 VDC ±10% (including ripple)
Ratings (Current consumption)Max. 1.9 A or less (With main unit only: 0.8 A or less, With unit expansion: 1.9 A or less) (Excluding output load)
Рабочая температура0 to +50°C 32 to 122°F (No freezing)
Environmental resistance (Relative humidity)35 to 85% RH (No condensation)
МатериалMain unit case: PC / Power connector: PA, POM / Analog output connector: PA, POM / I/O connector: PA / Head connector: Zinc + Ni plating, PA / Ethernet connector: Copper alloy + Ni plating / Rear heat sink: Aluminum / Main unit rear DIN rail fixing tab: POM / Nameplate: PC
МассаApprox. 210 g
Запросить КП по этой позиции