KE

KEYENCE CORPORATION NR-EN16

NR-X series (Multi-input Data Logger) - NR-EN16

  • Бренд: KEYENCE CORPORATION
  • Артикул (MPN): NR-EN16
  • Серия: NR-X Series
  • Статус производства: В производстве

Категории:

Технические характеристики

Connection target devicesDL-EN1 (Connected sensor: GT2 Series, GT Series, IL Series, IG Series, IB Series, IX Series, SK Series) NQ-EP4L (Connected sensor: FD-Q Series,FD-R Series, FD-X Series, FD-G Series, LR-T Series, FL Series, GP-M Series, FD-H Series, FD-EP Series, FD-EC Series, FI-1000, FI-T Series) ; LK-G5000 Series, CL-3000 Series, LJ-V7000 Series, LJ‑X8000 Series, LS-9000 Series; Connection of one of the above devices per NR-EN16 allowed
Connection target device identificationAutomatic identification or manual identification by specifying the IP address
Communication protocolsEthernet TCP/UDP communication, BOOTP/DHCP client supported (compatible with the above connection target devices)
InterfaceEthernet 100Base-TX (AUTO-MDI/MDIX-compatible), 1 port
Number of channels16 ch max. (varies depending on connected devices)
Collection periodMaximum sampling cycle: 1 ms (1 kHz) to 60 s With effective rate display function for communication between connected sensors
Buffer memory8M data
Sensor power output function• Output from power supply output connector (4-pole terminal block) (switchable between output ON and OFF) • Output voltage: 24 VDC ±10% • Rated current: Max. 0.6 A (switchable between 0.3 A and 0.6 A) • Built-in overcurrent protection function: Automatic recovery, switchable between 0.35 A (typ.) and 0.70 A (typ.) protection current • Class 2 power supply (CSA C22.2 No. 223 / UL 1310 compliant) • Sensor power supply not insulated from system bus
Power consumption1.6 W or less
Surrounding air temperature0 to +40°C 32°F to 104°F
Operating ambient humidity10 to 85% RH (no condensation)
МассаApprox. 150 g 5.30 oz (including approx. 10 g 0.35 oz for the OP-88513 (NR-EN16 power supply terminal block))
Запросить КП по этой позиции