KEYENCE CORPORATION NR-FV04
NR-X series (Multi-input Data Logger) - NR-FV04
Категории:
Технические характеристики
| Type | Pulse measurement unit |
|---|---|
| Input method | Insulated single-end input, channels insulated from each other, input channels insulated from other units (PC) |
| Number of channels | 4 ch |
| Measurement cycle | Maximum sampling cycle: 1 μs (1 MHz) to 60 s |
| A/D converting system | Successive approximation, simultaneous sampling of all channels |
| A/D resolution | 14 bit |
| Input frequency band | 250 kHz (−3 dB or more) |
| Low pass filter | PASS, 1.5 kHz, 15 kHz, 50 kHz |
| Pulse input (Input type) | Pulse frequency, pulse count (Single-phase input) |
| Напряжение питания | ±700 V |
| Напряжение питания | +100 V, +50 V, +20 V, +10 V, +5 V, +2.5 V, +1 V, +500 mV, +250 mV, +100 mV, +50 mV, 0 V |
| Pulse input (Minimum pulse duration) | 2 μs or more for both ON and OFF |
| Pulse input (Hysteresis) | AUTO, 100 mV, 500 mV, 5 V |
| Pulse input (Pulse divisions) | 1 to 64 (Can be set to units of 1 division) |
| Pulse input (Input coupling) | DC rising edge, DC falling edge, AC rising edge, AC falling edge |
| Pulse input (Digital filter) | Pulse frequency: Averaging rate of 1 to 32768 (automatically selected), Pulse count: None |
| Pulse input (Predictive functions) | Predictive calculation, Stop prediction (OFF, ×1.5, ×3, ×5, ×8, ×16) |
| Pulse input (Sensor power output) | Dedicated connectors for OP-88003 (AUX POWER) × 2 when using OP-88003; +12 V, 50 mA or +5 V, 50 mA NPN open-collector output connectable, sensor power supply not insulated from system bus |
| Напряжение питания | ±100 V, ±50 V, ±20 V, ±10 V, ±5 V, ±2 V |
| Напряжение питания | ±700 V |
| Напряжение питания | Averaging rate: 1 to 128 (automatically selected) |
| Напряжение питания | DC, AC |
| Напряжение питания | 80 dB or more (at up to 60 Hz DC) |
| Напряжение питания | 0.02% of F.S., LPF: 1.5 kHz (200 μs/S, digital filter: ON); 0.05% of F.S., LPF: PASS |
| Measurement range (Pulse frequency) | Measurable range: 0.05 to 16000.00 Hz, Display resolution: 0.01 to 1.00 Hz (selected automatically according to frequency) |
| Measurement range (Pulse count) | Measurable range: 0 to 65,000 counts/sampling cycle, Display resolution: 1 count |
| Measurement range (±100 V) | Measurable range: −110.000 to +110.000 V, Display resolution: 5 mV |
| Measurement range (±50 V) | Measurable range: −55.000 to +55.000 V, Display resolution: 2 mV |
| Measurement range (±20 V) | Measurable range: −22.000 to +22.000 V, Display resolution: 1 mV |
| Measurement range (±10 V) | Measurable range: −11.0000 to +11.0000 V, Display resolution: 0.5 mV |
| Measurement range (±5 V) | Measurable range: −5.5000 to +5.5000 V, Display resolution: 0.2 mV |
| Measurement range (±2 V) | Measurable range: −2.2000 to +2.2000 V, Display resolution: 0.1 mV |
| Measurement accuracy (Pulse frequency) | ±0.07% of rdg, ±0.01 Hz (20 Hz to 15 kHz, 20 ms/S, with digital filter ON) |
| Напряжение питания | ±0.1% of F.S., LPF: 500 Hz, with digital filter ON |
| Напряжение питания | 2200 VAC (50/60 Hz) for 1 minute |
| Connector format | Insulated BNC connector |
| Input impedance | 1 MΩ ±1%, approx. 30 pF |
| Buffer memory | 16M data |
| Warm up time | 30 minutes or more |
| Напряжение питания | [When using OP-89263 1:1 voltage-resistant probe] Measurement terminal, GND terminal: 300 Vrms (CAT II); [When using OP-89264 1:1 voltage-resistant probe] Measurement terminal, GND terminal: 300 Vrms (CAT II); [When using OP-88998 10:1 voltage-resistant probe] Measurement terminal: 700 Vrms (CAT II), GND terminal: 300 Vrms (CAT II); [Direct input] Measurement terminal, GND terminal: 42.4 Vpeak and 30 Vrms, or 60 VDC |
| Rating (Power consumption) | 4 W or less (including OP-88003 sensor power supply) |
| Environmental resistance (Insulation resistance) | 500 VDC, 10 MΩ or more |
| Рабочая температура | 0 to +40°C 32°F to 104°F |
| Environmental resistance (Relative humidity) | 10 to 85% RH (no condensation) |
| Масса | Approx. 270 g 9.53 oz |