KEYENCE CORPORATION NR-X100W
NR-X series (Multi-input Data Logger) - NR-X100W
Категории:
Технические характеристики
| Main unit buffer memory capacity | 50M data |
|---|---|
| Expansion memory | SD card (SD/SDHC) |
| PC interface (USB) | USB mini-B connector, USB 2.0 High-speed–compliant, Simultaneous USB connection from one PC to up to four units (switchable by ID switch) |
| PC interface (Ethernet) | RJ45 connector, 100Base-TX (AUTO MDI/MDIX supported) |
| PC interface (Wireless LAN) | Connection via NR-XW1 wireless LAN unit, IEEE 802.11b/g/n |
| Network function | FTP client function, FTP server function, SNTP client function |
| Display/operation | Operation via NR-XCP30 control panel, or via WAVE LOGGER X with PC connection |
| Expansion remote unit connection | Dedicated remote connection connector × 2 (Remote OUT A port, B port) Unit expansion possible by connecting up to eight NR-XR01 remote units (connected by remote unit cable) |
| Number of connectable measurement units (Master data collection unit group) | Max. 8 units |
| Number of connectable measurement units (Total with remote units connected) | Max. 72 units |
| Continuous acquisition speed (Master data collection unit group) | Max. 100 kHz for all acquisition channels |
| Continuous acquisition speed (Total with remote units connected) | Max. 500 kHz for all acquisition channels |
| Inter-unit synchronization (Between measurement units in the master data collection unit group) | ±1 μs or less |
| Time axis accuracy | ±50 ppm (23°C ±3°C 73.4°F ±5.4°F ); Same time used for all remote groups, SNTP server time synchronization possible |
| Synchronous trigger input (SYNC input) (Performance specifications) | • Use as external trigger input (normal mode) or synchronous acquisition input (logging mode) • Non-voltage (contact/non-contact)/voltage input, Falling edge input • Not insulated from system bus |
| Synchronous trigger input (SYNC input) (Input specifications) | • For non-voltage input: ON voltage 1.0 V or lower (short circuit current: 1 mA typ.), OFF current 0.1 mA or lower • For voltage input: ON voltage (Lo) 1.0 V or lower, OFF voltage (Hi) 2.4 V or more, Max. input voltage: 6 V |
| Control input (Common specifications) | • Input type: Bidirectional voltage input • Maximum rating: 30 VDC, Minimum ON voltage: 10 VDC, Maximum OFF current: 0.2 mA • Insulation between input and system bus (500 VDC/1 minute) |
| Control input (Individual specifications) | • External trigger input (TRG IN): Edge input • Acquisition start/stop input (START IN): Level input (only enabled in external control mode) • Auto-balance input (BAL): Edge input (only enabled in external control mode) • Program selection input 0 to 3 (PROG IN0 to 3): Level input (only enabled in external control mode) |
| Control output (Common specifications) | • Output format: Photo MOS relay output • Maximum rating: 36 VDC, Output current: 50 mA or less (9-point total: 300 mA or less) • Leak current at OFF: 0.1 mA or less, Residual voltage when ON: 1 V or less • Insulation between output and system bus (500 VDC/1 minute) |
| Control output (Individual specifications) | • Trigger output (TRG OUT): N.O. output, one-shot output • System error output (SYS ERR): N.C. output • Alarm output (ALARM): N.O. output • Judgment output 1 to 4 (OUT1 to 4): N.O. output • Ready output (READY): N.O. output |
| Power supply | • NR-XU1 AC adapter, or 9 to 36 VDC (including ripple) / Max. 72 W (when connected to DC terminal block; at 9 V: 8.0 A or less; at 24 V: 3.0 A or less; at 36 V: 2.0 A or less) • Battery operation possible when connected to the NR-XU15 Series battery power supply unit |
| Power supply (Power consumption) | 8.4 W or less (excluding connected units) |
| Рабочая температура | 0 to +40°C 32°F to 104°F |
| Environmental resistance (Relative humidity) | 10 to 85% RH (no condensation) |
| Масса | Approx. 490 g 17.30 oz (including approx. 10 g 0.35 oz for the OP-88512 (NR-X100W I/O terminal block)) |