EMU4-HD1-MB

Mitsubishi Electric Corporation (Factory Automation / FA Systems Group) EMU4-HD1-MB

EMU4-HD1-MB

Технические характеристики

CategoryEnergy Saving Supporting Devices
GroupEnergy Measuring Unit
ModelEcoMonitorLight
UseHigh Performance Model
TransmissionMODBUS RTU (RS-485) communication
Phase wire systemSingle-phase 2-wire, single-phase 3-wire, 3-phase 3-wire, 3-phase 4-wire common
Single-phase 2-wire 3-phase 3-wire110V, 220V, 440V AC common
Single-phase 3-wire110V AC (between wires 1 and 2, and wires 2 and 3), 220V AC (between wires 1 and 3)
3-phase 4-wireMinimum: 63.5V/110V AC, Maximum: 277V/480V AC
Current circuit50A, 100A, 250A, 400A, 600A (Dedicated split-type current sensor is used. All values indicate primary current values of current sensor.) 5A(Dedicated 5A current sensor is used. Current transformer (CT) is used in two-step configuration together with the 5A current sensor in order to allow a maximum primary current value setting of 6,000A)
Frequency50-60Hz (automatic frequency selection)
Auxiliary power rating100V-240V AC (+10%, -15%) 50Hz/60Hz
No. of measurement circuits1 circuit
Напряжение питанияFor each phase: 0.1VA (110V AC), 0.2VA (220V AC), 0.4VA (440V AC)
Auxiliary power circuit110V AC: 9VA, 220V AC: 10VA
Measurement itemsCurrent, demanded current, voltage, power, demanded power, reactive power, power factor, frequency, electric energy (regenerative, consumption), reactive electric energy, operating time, apparent power, harmonic current, harmonic voltage, pulse count value, periodic electric energy, CO 2 conversion value
Main unit tolerancesCurrent, voltage, power, reactive power, apparent power, frequency: ±1.0% (relative to rated input) Power factor: ±3.0% Electric energy: ±2.0% (in 5 to 100% range of rated values; power factor = 1) Reactive electric energy: ±2.5% (in 10 to 100% range of rated values; power factor = 0) Harmonic current, harmonic voltage: ±2.5%
Data update cycle250 ms *Electric energy and reactive electric energy are always sampled (following short-cycle load fluctuation also).
Input signal formatNon-voltage a-contact or open collector 1 input
Output signal formatNon-voltage a-contact, 1 output
Output itemElectric energy
Output signal typeNon-voltage a-contact, 1 output ・Pulse units (kWh/pulse): 0.001, 0.01, 0.1, 1, 10, 100
Compatible standardCE marking (EMC: EN-61326-1: 2006, Safety: EN-61010-1: 2010), UL: UL61010-1
Масса0.3kg
External dimensions (unit: mm)75 (W) x 90 (H) x 75 (D) (excluding protruding parts)
Category (site listing)EcoMonitorLight