EMU4-HM1-MB

Mitsubishi Electric Corporation (Factory Automation / FA Systems Group) EMU4-HM1-MB

EMU4-HM1-MB

Технические характеристики

CategoryEnergy Saving Supporting Devices
GroupEnergy Measuring Unit
ModelEcoMonitorPlus
UseEnergy Measuring High Performance Model
TransmissionMODBUS RTU (RS-485) communication
Phase wire systemSingle-phase 2-wire, single-phase 3-wire, 3-phase 3-wire, 3-phase 4-wire common
Single-phase 2-wire 3-phase 3-wire110V, 220V, 440V AC common
Single-phase 3-wire110V AC (between wires 1 and 2, and wires 2 and 3), 220V AC (between wires 1 and 3) 220V AC (between wires 1 and 2, and wires 2 and 3), 440V AC (between wires 1 and 3)
3-phase 4-wireMinimum: 63.5V/110V AC, Maximum: 277V/480V AC
Current circuit50A, 100A, 250A, 400A, 600A (Dedicated split-type current sensor is used. All values indicate primary current values of current sensor.) 5A(Dedicated 5A current sensor is used. Current transformer (CT) is used in two-step configuration together with the 5A current sensor in order to allow a maximum primary current value setting of 30,000A)
Frequency50/60Hz (automatic frequency selection)
Auxiliary power rating100V-240V AC (+10%, -15%) 50Hz/60Hz
No. of measurement circuits1 circuit (single-phase 2-wire system: 2 circuits*) *Available for single-phase 2-wire system branched from single-phase 3-wire system.
Напряжение питанияFor each phase: 0.1VA (110V AC), 0.2VA (220V AC), 0.4VA (440V AC)
Auxiliary power circuit110V AC: 2.0VA, 220V AC: 3.0VA
Measurement itemsCurrent, demanded current, voltage, power, demanded power, reactive power, power factor, frequency, electric energy (regenerative, consumption), reactive electric energy, current imbalance rate, voltage imbalance rate, operating time, apparent power, periodic electric energy, harmonic current, harmonic voltage, pulse count value, pulse conversion value, electric energy conversion value
Main unit tolerancesCurrent, voltage, power, reactive power, apparent power, frequency: ±1.0% (relative to rated input) Power factor: ±3.0% Electric energy: ±2.0% (in 5 to 100% range of rated values; power factor = 1) Reactive electric energy: ±2.5% (in 10 to 100% range of rated values; power factor = 0) Harmonic current, harmonic voltage: ±2.5%
Data update cycle100msec
Input signal formatNon-voltage a-contact, 1 output or open-collector
FunctionContact / pulse input
Output signal formatNon-voltage a-contact, 1 output
Output itemElectric Energy
Output signal typeNon-voltage a-contact, 1 output
Compatible standardCE marking (EMC: EN-61326-1: 2013, Safety: EN-61010-1: 2010), UL: UL61010-1
Масса0.2kg
External dimensions (unit: mm)37.5 (W) x 90 (H) x 92.9 (D) (excluding protruding parts) (Maximum size including projections: 41.5 (W) x 99 (H) x 94 (D))
Category (site listing)EcoMonitorPlus