EMU4-LM

Mitsubishi Electric Corporation (Factory Automation / FA Systems Group) EMU4-LM

EMU4-LM

Технические характеристики

CategoryEnergy Saving Supporting Devices
GroupEnergy Measuring Unit
ModelEcoMonitorLight EcoMonitorPlus
UseLogging Unit
Ratings6.4V DC (supplied from energy measuring unit)
Power interruption backupTotal power interruption backup time of the battery (EMU4-BT) is one year (ave. daily temp. of 35℃ or lower). It is recommended to replace the battery every three years.
Set valueSaved in non-volatile memory * Data will not be lost even if power outage occurs.
Logging data System log dataSaved in volatile memory * Data will be lost if power outage occurs when the battery voltage is low (BAT.LED is lit).
Timer operationTimer operation continues by using the battery in the event of power outage. * Timer operation stops if the battery voltage is low (BAT.LED is lit) when power outage occurs.  After power is recovered, timer operation starts from 2013/01/01 00:00:00.
Clock accuracy1 min/month
Output data storage media *1SD memory card (SD, SDHC)
Compatible modelEnergy measuring unit (EcoMonitorLight) Model: EMU4-BD1-MB, EMU4-HD1-MB Energy measuring unit (EcoMonitorPlus) Model: EMU4-BM1-MB, EMU4-HM1-MB, EMU4-LG1-MB, EMU4-CNT-MB, EMU4-VA2, EMU4-A2, EMU4-AX4, EMU4-PX4
Compatible standardEMC: EN-61326-1: 2013
Operating temperature-5℃ to +55℃ (ave. daily temp. of +35℃ or lower)
Operating humidity30% to 85%RH (no condensation)
Storage temperature-10℃ to +60℃ (ave. daily temp. of +35℃ or lower)
Altitude2,000m or lower
Масса0.1 kg (Wight of logging unit only)
External dimensions (unit: mm)25 (W) x 90 (H) x 60 (D) (excluding protruding parts)
Parts sold separatelySD memory card (EMU4-SD2GB, EMU4-SD16GB) *1*2
Consumables sold separatelyBattery (EMU4-BT) *2
Automatic updateAutomatic overwrite/update
Date/time designationAutomatic start/stop according to start time setting
Detailed dataMeasurement data is saved according to set "Detailed Data Logging Cycle" (1 sec, 1 min, 5 min, 10 min, 15 min, 30 min). * Output as a detailed data file
1-Hour dataMeasurement data is saved in 1-hour cycles. * Output as 1-hour and 1-day data files.
Logging Specification > Number of logging elements > Detailed dataDetailed data logging cycle of 1 sec → Maximum of 4 elements Detailed data logging cycle of other than 1 sec → Maximum of 10 elements
Logging Specification > Number of logging elements > 1-Hour dataMaximum of 10 elements
System log data3,600 records
Logging data and system log data output formatCSV format (ASCII code)
Category (site listing)EcoMonitorLight EcoMonitorPlus
Получить предложение по этой позиции