Mitsubishi Electric Corporation (Factory Automation / FA Systems Group) FX3GC-32MT/DSS
FX3GC-32MT/DSS
Технические характеристики
| Operation control system | Stored program repetitive operation system with interruption function |
|---|---|
| Input/output control system | Batch processing system (when END instruction is executed), Input/output refresh instruction and pulse catch function are provided. |
| Programming language | Sequence program |
| Max. memory capacity | 32000 steps 32000 steps including comments and file registers |
| Built-in memory capacity/type | 32000 steps EEPROM (memory backup not required) |
| Writing function during running | Provided (Program can be modified while the PLC is running.) |
| Protection | With keyword/Customer keyword function |
| Clock function | Built-in 1980 to 2079 (with correction for leap year), 2- or 4-digit year, accuracy within ±45 seconds/month at 25°C *Precaution for clock function The current time of the built-in clock is backed up by a high-capacity capacitor (built-in). The large-capacity capacitor (built-in) fully charges in 30 minutes and retains the current value for ten days. The optional battery can also be used to hold the time. |
| Basic instructions | ・Sequence instructions: 29 ・Step-ladder instructions: 2 |
| Applied instructions | Applied instructions: 120 kinds |
| Processing speed > Basic instructions | Standard mode: 0.21 μs/instruction (if the capacity for programming is set to less than 16000 steps) Extension mode: 0.42 μs/instruction (if the capacity for programming is set to more than 16001 steps) |
| Processing speed > Applied instructions | Standard mode: 0.5 μs to several hundred μs/instruction (if the capacity for programming is set to less than 16000 steps) Extension mode: 1.2 μs to several hundred μs/instruction (if the capacity for programming is set to more than 16001 steps) |
| No. of input points | 16 points |
| No. of output points | 16 points |
| CC-Link | (3) 128 points or less *The total number of remote I/O points in CC-Link and AnyWireASLINK must be 128 points or less. |
| AnyWireASLINK | (3) 128 points or less *The total number of remote I/O points in CC-Link and AnyWireASLINK must be 128 points or less. |
| Total number of points | Total of (1)+(2)+(3): 256 points or less (Extension-combined) |
| Input relay | X000 to X177 128 points (octal) Extension-combined |
| Output relay | Y000 to Y177 128 points (octal) Extension-combined |
| For general | M0 to M383 384 points |
| For keeping (EEPROM keep) | M384 to M1535 1152 points *Precaution for keeping area The keeping area other than M1536 to M7679 and non-keeping area are fixed. (Cannot be changed with parameter) |
| For general-purpose (can be changed to keeping) | M1536 to M7679 6144 points These devices can be changed to the keep (battery backup) type using a parameter when the optional battery is used. |
| For special | M8000 to M8511: 512 points |
| Initial state (EEPROM keep) | S0 to S9 10 points |
| Device > State > For keeping (EEPROM keep) | S10 to S999 990 points |
| Device > State > For general | S1000 to S4095 3096 points These devices can be changed to the keep (battery backup) type using a parameter when the optional battery is used. |
| 100 ms | T0 to T191: 192 points (0.1 to 3,276.7 sec) |
| 100 ms (for subroutine/interruption subroutine) | T192 to T199: 8 points (0.1 to 3,276.7 sec) |
| 10 ms | T200 to T245: 46 points (0.01 to 327.67 sec) |
| 1 ms accumulating type (EEPROM keep) | T246 to T249 4 points (0.001 to 32.767 sec) *Precaution for the retentive status The retentive status is fixed. (Cannot be changed with parameter) |
| 100 ms accumulating type (EEPROM keep) | T250 to T255 6 points (0.1 to 3,276.7 sec) *Precaution for the retentive status The retentive status is fixed. (Cannot be changed with parameter) |
| 1 ms | T256 to T319 64 points (0.001 to 32.767 sec) |
| 16 bits up | C0 to C15 16 points (Counting from 0 to 32,767) |
| 16 bits up (EEPROM keep) | C16 to C199 184 points (Counting from 0 to 32,767) *Precaution for the retentive status The retentive status is fixed. (Cannot be changed with parameter) |
| 32 bits up or down | C200 to C219 20 points (Counting from -2,147,483,648 to +2,147,483,647) |
| 32 bits up/down (EEPROM keep) | C220 to C234 15 points (Counting from -2,147,483,648 to +2,147,483,647) *Precaution for the retentive status The retentive status is fixed. (Cannot be changed with parameter) |
| High-speed counter | [32 bits high-speed up/down (EEPROM keep)] Up to 6 points can be used between C235 and C255. 1-phase: 60 kHz, 10 kHz 2-phase: 30 kHz, 5 kHz The number of points that can be used and the input frequency are limited depending on the conditions of use. |
| 16 bits for general | D0 to D127 128 points |
| For 16 bits keep (EEPROM keep) | D128 to D1099 972 points |
| For 16 bits general (can be changed to keeping) | D1100 to D7999 6900 points These devices can be changed to the keep (battery backup) type using a parameter when the optional battery is used. |
| File register (EEPROM keep) | D1000 to D7999 Maximum 7000 points (Can be set as file registers in units of 500 points from D1000 in the program area (EEPROM) using parameters.) |
| 16 bits for special | D8000 to D8511: 512 points |
| 16 bits for index | V0 to V7, Z0 to Z7: 16 points |
| Device > Extension register > For 16 bits general (can be changed to keeping) | R0 to R23999 24000 points These devices can be changed to the keep (battery backup) type using a parameter when the optional battery is used. |
| 16 bits (EEPROM keep) | ER0 to ER23999 24000 points Stored in the EEPROM built-in the main unit |
| For branching of JUMP and CALL | P0 to P2047 2048 points (For CJ instructions and CALL instructions, P63 jumps to END instruction) |
| Input interruption | I00□ to I50□: 6 points |
| Timer interruption | I6□□ to I8□□: 3 points |
| Nesting | [For master control] I00□ to I50□ 6 points |
| Decimal number (K) | 16 bits: -32,768 to +32,767 32 bits: -2,147,483,648 to +2,147,483,647 |
| Hexadecimal number (H) | 16 bits: 0 to FFFF 32 bits: 0 to FFFFFFFF |
| Real number (E) | 32 bits: -1.0 × 2 128 to -1.0 × 2 -126 , 0, 1.0 × 2 -126 to 1.0 × 2 128 Decimal-point and exponential notations are possible. |
| Напряжение питания | 24 V DC Use an external power supply of 24 V DC ±10% when connecting the FX2NC-64ET or FX2N-32CCL. |
| Напряжение питания | 20.4 V to 28.8 V DC |
| Allowable instantaneous power failure time | Operation can be continued upon occurrence of instantaneous power failure for 5 ms or less. |
| Power fuse | 125V 3.15 A |
| Rush current | 35 A max. 0.5 ms / 24 V DC |
| Power consumption | 8 W (Power consumption changes according to the system configuration.) |
| Input connection type | Connector |
| Input type | Sink |
| Напряжение питания | 24 V DC +20% -15% |
| X000 to X007 | 3.3 kΩ |
| X010 or more | 4.3 kΩ |
| Input signal current > X000 to X007 | 7 mA/24 V DC |
| Input signal current > X010 or more | 5 mA/24 V DC |
| ON input sensitivity current > X000 to X007 | 4.5 mA or more |
| ON input sensitivity current > X010 or more | 3.5 mA or more |
| OFF input sensitivity current | 1.5 mA or less |
| Время отклика | Approx. 10 ms X000 to X007 have built-in digital filters, which can be changed to 0 to 15 ms in 1 ms increments using the application instructions or D8020. The following is applied when 0 is set. X000, X001, X003, X004: 10 μs X002, X005, X006, X007: 50 μs |
| Input signal form | No-voltage contact input Sink: NPN open collector transistor Source: PNP open collector transistor |
| Input circuit insulation | Photocoupler insulation |
| Indication of input operation | When photocoupler is driven, LED on panel is lit. |
| Output connection type | Connector |
| Output type | Transistor/source output |
| External power supply | 5-30 V DC |
| Resistance load | 0.3 A/1 point (Y000, Y001) 0.1 A/1 point (Y002 to Y017) Make sure that the total load current of 8 resistance load points is 0.8 A or less. When the two COM1 terminals are connected outside the PLC, resistance load is 1.6 A or less. |
| Inductive load | [Y000, Y001] 7.2 W/1 point (24 V DC) Make sure that the total load of 16 inductive load points is 38.4W/24 V DC or less. [Y002 to Y017] 2.4 W/1 point (24 V DC) Make sure that the total load of 16 inductive load points is 38.4W/24 V DC or less. |
| Open circuit leakage current | 0.1 mA or less/30 V DC |
| Напряжение питания | 1.5 V or less |
| OFF→ON | [Y000, Y001] 5μs or less/10 mA or more (5-24 V DC) [Y002 to Y017] 0.2 ms or less/100 mA (24 V DC) |
| ON→OFF | [Y000, Y001] 5μs or less/10 mA or more (5-24 V DC) [Y002 to Y017] 0.2 ms or less/100 mA (24 V DC) |
| Insulation of circuit | Photocoupler insulation |
| Indication of output operation | LED on panel lights when photocoupler is driven. |
| 1-phase 1-count input | [C235, C236] 60 kHz [C237] 10 kHz [C238, C239] 60 kHz [C240] 10 kHz [C241] 60 kHz [C242 to C245] 10 kHz When using multiple high-speed counters, make sure that the sum of used frequency does not exceed the overall frequency. |
| 1-phase 2-count input | [C246, C248(OP)] 60 kHz [C247, C248] 10 kHz [C249, C250] 10 kHz When using multiple high-speed counters, make sure that the sum of used frequency does not exceed the overall frequency. |
| 2-phase 2-count input | [C251, C253(OP)] 30 kHz [C254(OP)] 5 kHz [C252, C253] 5 kHz [C254, C255] 5 kHz When using multiple high-speed counters, make sure that the sum of used frequency does not exceed the overall frequency. |
| Number of control axes | 2 independent axes |
| Maximum frequency | 100 kHz |
| Compatible main units | Transistor output type main unit |
| Pulse output instruction | ・Pulse Y Output (PLSY) ・Acceleration/Deceleration Setup (PLSR) Pulse output form: Pulse train (The direction is controlled with the sequence.) |
| Positioning instruction | ・Reads out the current value of ABS ([D]ABS) ・zero return with DOG search function [DSZR] ・zero return [ZRN] (without DOG search function) Decelerates when near-point DOG is ON, Stops when near-point DOG is OFF. (This is different from the zero return operation by counting the zero point signal.) ・Variable speed Pulse Output [PLSV] ・Drive to Increment [DRVI] ・Drive to Absolute [DRVA] ・Positioning using batch setting method ([D]TBL) Pulse output form: "Pulse train + direction" method |
| Рабочая температура | 0 to 55°C (32 to 131°F) when operating and -25 to 75°C (-13 to 167°F) when stored |
| Ambient humidity | 5 to 95%RH (no condensation) when operating |
| Frequency: 10 to 57 Hz | Half amplitude: 0.035mm Sweep Count for X, Y, Z: 10 times (80 min in each direction) The criterion is shown in IEC61131-2. |
| Frequency: 57 to 150 Hz | Acceleration: 4.9 m/s 2 Sweep Count for X, Y, Z: 10 times (80 min in each direction) The criterion is shown in IEC61131-2. |
| Shock resistance | 147 m/s 2 Acceleration, Action time: 11 ms, 3 times by half-sine pulse in each direction X, Y, and Z The criterion is shown in IEC61131-2. |
| Noise resistance | By noise simulator at noise voltage of 1,000 Vp-p, noise width of 1 μs, rise time of 1 ns and period of 30 to 100 Hz |
| Напряжение питания | Between batch of all terminals and ground terminal: 500 V AC for one minute |
| Insulation resistance | Between batch of all terminals and ground terminal: 5 MΩ or higher by 500 V DC insulation resistance tester |
| Grounding | Class D grounding (grounding resistance: 100 Ω or less) (Common grounding with a heavy electrical system is not allowed) Ground the PLC independently or jointly. |
| Working atmosphere | Free from corrosive or flammable gas and excessive conductive dusts |
| Working altitude | 2000 m or less Do not use the PLC under pressure higher than the atmospheric pressure. Doing so may damage the PLC. |
| Category (site listing) | Main unit |