MS-2XN220

Mitsubishi Electric Corporation (Factory Automation / FA Systems Group) MS-2XN220

MS-2xN220

Технические характеристики

Product SpecificationEnclosed Reversible Type
Напряжение питания690(1000)
AC200 to 220V55
AC380 to 440V110
AC500 to 550V132
AC220 to 240V75
Main Contact Rating [Kw] > Three-Phase Squirrel-Cage Motor (Category AC-3)(Global) > AC380 to 440V132
AC500V132
AC690V132
Main Contact Rated Operating Current [A] > Three-Phase Squirrel-Cage Motor (Category AC-3)(Japan) > AC200 to 220V220
Main Contact Rated Operating Current [A] > Three-Phase Squirrel-Cage Motor (Category AC-3)(Japan) > AC380 to 440V220
Main Contact Rated Operating Current [A] > Three-Phase Squirrel-Cage Motor (Category AC-3)(Japan) > AC500 to 550V200
Main Contact Rated Operating Current [A] > Three-Phase Squirrel-Cage Motor (Category AC-3)(Global) > AC220 to 240V250
Main Contact Rated Operating Current [A] > Three-Phase Squirrel-Cage Motor (Category AC-3)(Global) > AC380 to 440V250
Main Contact Rated Operating Current [A] > Three-Phase Squirrel-Cage Motor (Category AC-3)(Global) > AC500V200
Main Contact Rated Operating Current [A] > Three-Phase Squirrel-Cage Motor (Category AC-3)(Global) > AC690V150
Main Contact Conventional Free Air Thermal Current [A]260
Main Contact Minimal Applicable Load48V 200mA
AC120V6
AC240V3
AC440V1.5
AC550V1.2
Auxiliary Contact Rated Operating Current [A] > AC Resistive Load (Category AC-12) > AC120V10
Auxiliary Contact Rated Operating Current [A] > AC Resistive Load (Category AC-12) > AC240V8
Auxiliary Contact Rated Operating Current [A] > AC Resistive Load (Category AC-12) > AC440V5
Auxiliary Contact Rated Operating Current [A] > AC Resistive Load (Category AC-12) > AC550V5
DC24V3
DC48V1.5
DC110V0.6
DC220V0.3
Auxiliary Contact Rated Operating Current [A] > DC Resistive Load (Category DC-12) > DC24V10
Auxiliary Contact Rated Operating Current [A] > DC Resistive Load (Category DC-12) > DC48V8
Auxiliary Contact Rated Operating Current [A] > DC Resistive Load (Category DC-12) > DC110V5
Auxiliary Contact Rated Operating Current [A] > DC Resistive Load (Category DC-12) > DC220V1
Auxiliary Contact Conventional Free Air Thermal Current [A]10
Auxiliary Contact Minimal Applicable Load20V 3mA
Main Contact (Standard)3NO×2
Auxiliary Contact (Standard)2NO2NC×2
Auxiliary Contact (Special)-
AC220V2500
Main Contact Making Current Capacity [A] > Category AC-3 > AC440V2500
Main Contact Making Current Capacity [A] > Category AC-3 > AC550V2000
Main Contact Making Current Capacity [A] > Category AC-3 > AC690V1500
Main Contact Breaking Current Capacity [A] > Category AC-3 > AC220V2000
Main Contact Breaking Current Capacity [A] > Category AC-3 > AC440V2000
Main Contact Breaking Current Capacity [A] > Category AC-3 > AC550V1600
Main Contact Breaking Current Capacity [A] > Category AC-3 > AC690V1200
Mechanical Durability [Mil.Times]500
Category AC-3 (Japan)100
Category AC-31200
Напряжение питанияAC Operated
Inrush Input [VA]440
Normal input [VA]40
Power Consumption [W]4.2
Protection Mode of Thermal Overload Relay2-element(Overload and Constraint Protection)
Coil Surge Absorbing FunctionYes
Terminal CoversNo
Wiring Streamlining TerminalNo
Mounting MethodScrew Mounting
Main Circuit (Power Side)M10
Main Circuit (Load Side)M10
Operating CircuitM4
Operation CoilM4
Category (site listing)Representative rating 220A (Category AC-3 AC200V) AC Operated Enclosed Type Reversible Type 2-Element Thermal Overload Relay
Получить предложение по этой позиции