Mitsubishi Electric Corporation (Factory Automation / FA Systems Group) MS-2XN25
MS-2xN25
Технические характеристики
| Product Specification | Enclosed Reversible Type |
|---|---|
| Напряжение питания | 690 |
| AC200 to 220V | 5.5 |
| AC380 to 440V | 11 |
| AC500 to 550V | 11 |
| AC220 to 240V | 7.5 |
| Main Contact Rating [Kw] > Three-Phase Squirrel-Cage Motor (Category AC-3)(Global) > AC380 to 440V | 15 |
| AC500V | 15 |
| AC690V | 11 |
| Main Contact Rated Operating Current [A] > Three-Phase Squirrel-Cage Motor (Category AC-3)(Japan) > AC200 to 220V | 26 |
| Main Contact Rated Operating Current [A] > Three-Phase Squirrel-Cage Motor (Category AC-3)(Japan) > AC380 to 440V | 25 |
| Main Contact Rated Operating Current [A] > Three-Phase Squirrel-Cage Motor (Category AC-3)(Japan) > AC500 to 550V | 20 |
| Main Contact Rated Operating Current [A] > Three-Phase Squirrel-Cage Motor (Category AC-3)(Global) > AC220 to 240V | 30 |
| Main Contact Rated Operating Current [A] > Three-Phase Squirrel-Cage Motor (Category AC-3)(Global) > AC380 to 440V | 30 |
| Main Contact Rated Operating Current [A] > Three-Phase Squirrel-Cage Motor (Category AC-3)(Global) > AC500V | 24 |
| Main Contact Rated Operating Current [A] > Three-Phase Squirrel-Cage Motor (Category AC-3)(Global) > AC690V | 12 |
| Main Contact Conventional Free Air Thermal Current [A] | 50 |
| Main Contact Minimal Applicable Load | 48V 200mA |
| AC120V | 6 |
| AC240V | 3 |
| AC440V | 1.5 |
| AC550V | 1.2 |
| Auxiliary Contact Rated Operating Current [A] > AC Resistive Load (Category AC-12) > AC120V | 10 |
| Auxiliary Contact Rated Operating Current [A] > AC Resistive Load (Category AC-12) > AC240V | 8 |
| Auxiliary Contact Rated Operating Current [A] > AC Resistive Load (Category AC-12) > AC440V | 5 |
| Auxiliary Contact Rated Operating Current [A] > AC Resistive Load (Category AC-12) > AC550V | 5 |
| DC24V | 3 |
| DC48V | 1.5 |
| DC110V | 0.6 |
| DC220V | 0.3 |
| Auxiliary Contact Rated Operating Current [A] > DC Resistive Load (Category DC-12) > DC24V | 10 |
| Auxiliary Contact Rated Operating Current [A] > DC Resistive Load (Category DC-12) > DC48V | 8 |
| Auxiliary Contact Rated Operating Current [A] > DC Resistive Load (Category DC-12) > DC110V | 5 |
| Auxiliary Contact Rated Operating Current [A] > DC Resistive Load (Category DC-12) > DC220V | 1 |
| Auxiliary Contact Conventional Free Air Thermal Current [A] | 10 |
| Auxiliary Contact Minimal Applicable Load | 20V 3mA |
| Main Contact (Standard) | 3NO×2 |
| Auxiliary Contact (Standard) | 2NO2NC×2 |
| Auxiliary Contact (Special) | - |
| AC220V | 300 |
| Main Contact Making Current Capacity [A] > Category AC-3 > AC440V | 300 |
| Main Contact Making Current Capacity [A] > Category AC-3 > AC550V | 240 |
| Main Contact Making Current Capacity [A] > Category AC-3 > AC690V | 120 |
| Main Contact Breaking Current Capacity [A] > Category AC-3 > AC220V | 240 |
| Main Contact Breaking Current Capacity [A] > Category AC-3 > AC440V | 240 |
| Main Contact Breaking Current Capacity [A] > Category AC-3 > AC550V | 192 |
| Main Contact Breaking Current Capacity [A] > Category AC-3 > AC690V | 96 |
| Mechanical Durability [Mil.Times] | 1000 |
| Category AC-3 (Japan) | 200 |
| Category AC-3 | 1800 |
| Напряжение питания | AC Operated |
| Inrush Input [VA] | 110 |
| Normal input [VA] | 13 |
| Power Consumption [W] | 4.3 |
| Protection Mode of Thermal Overload Relay | 2-element(Overload and Constraint Protection) |
| Coil Surge Absorbing Function | No |
| Terminal Covers | No |
| Wiring Streamlining Terminal | No |
| Mounting Method | Screw Mounting |
| Main Circuit (Power Side) | M5 |
| Main Circuit (Load Side) | M5 |
| Operating Circuit | M3.5 |
| Operation Coil | M3.5 |
| Category (site listing) | Representative rating 26A (Category AC-3 AC200V) AC Operated Enclosed Type Reversible Type 2-Element Thermal Overload Relay |