MS-2XN25

Mitsubishi Electric Corporation (Factory Automation / FA Systems Group) MS-2XN25

MS-2xN25

Технические характеристики

Product SpecificationEnclosed Reversible Type
Напряжение питания690
AC200 to 220V5.5
AC380 to 440V11
AC500 to 550V11
AC220 to 240V7.5
Main Contact Rating [Kw] > Three-Phase Squirrel-Cage Motor (Category AC-3)(Global) > AC380 to 440V15
AC500V15
AC690V11
Main Contact Rated Operating Current [A] > Three-Phase Squirrel-Cage Motor (Category AC-3)(Japan) > AC200 to 220V26
Main Contact Rated Operating Current [A] > Three-Phase Squirrel-Cage Motor (Category AC-3)(Japan) > AC380 to 440V25
Main Contact Rated Operating Current [A] > Three-Phase Squirrel-Cage Motor (Category AC-3)(Japan) > AC500 to 550V20
Main Contact Rated Operating Current [A] > Three-Phase Squirrel-Cage Motor (Category AC-3)(Global) > AC220 to 240V30
Main Contact Rated Operating Current [A] > Three-Phase Squirrel-Cage Motor (Category AC-3)(Global) > AC380 to 440V30
Main Contact Rated Operating Current [A] > Three-Phase Squirrel-Cage Motor (Category AC-3)(Global) > AC500V24
Main Contact Rated Operating Current [A] > Three-Phase Squirrel-Cage Motor (Category AC-3)(Global) > AC690V12
Main Contact Conventional Free Air Thermal Current [A]50
Main Contact Minimal Applicable Load48V 200mA
AC120V6
AC240V3
AC440V1.5
AC550V1.2
Auxiliary Contact Rated Operating Current [A] > AC Resistive Load (Category AC-12) > AC120V10
Auxiliary Contact Rated Operating Current [A] > AC Resistive Load (Category AC-12) > AC240V8
Auxiliary Contact Rated Operating Current [A] > AC Resistive Load (Category AC-12) > AC440V5
Auxiliary Contact Rated Operating Current [A] > AC Resistive Load (Category AC-12) > AC550V5
DC24V3
DC48V1.5
DC110V0.6
DC220V0.3
Auxiliary Contact Rated Operating Current [A] > DC Resistive Load (Category DC-12) > DC24V10
Auxiliary Contact Rated Operating Current [A] > DC Resistive Load (Category DC-12) > DC48V8
Auxiliary Contact Rated Operating Current [A] > DC Resistive Load (Category DC-12) > DC110V5
Auxiliary Contact Rated Operating Current [A] > DC Resistive Load (Category DC-12) > DC220V1
Auxiliary Contact Conventional Free Air Thermal Current [A]10
Auxiliary Contact Minimal Applicable Load20V 3mA
Main Contact (Standard)3NO×2
Auxiliary Contact (Standard)2NO2NC×2
Auxiliary Contact (Special)-
AC220V300
Main Contact Making Current Capacity [A] > Category AC-3 > AC440V300
Main Contact Making Current Capacity [A] > Category AC-3 > AC550V240
Main Contact Making Current Capacity [A] > Category AC-3 > AC690V120
Main Contact Breaking Current Capacity [A] > Category AC-3 > AC220V240
Main Contact Breaking Current Capacity [A] > Category AC-3 > AC440V240
Main Contact Breaking Current Capacity [A] > Category AC-3 > AC550V192
Main Contact Breaking Current Capacity [A] > Category AC-3 > AC690V96
Mechanical Durability [Mil.Times]1000
Category AC-3 (Japan)200
Category AC-31800
Напряжение питанияAC Operated
Inrush Input [VA]110
Normal input [VA]13
Power Consumption [W]4.3
Protection Mode of Thermal Overload Relay2-element(Overload and Constraint Protection)
Coil Surge Absorbing FunctionNo
Terminal CoversNo
Wiring Streamlining TerminalNo
Mounting MethodScrew Mounting
Main Circuit (Power Side)M5
Main Circuit (Load Side)M5
Operating CircuitM3.5
Operation CoilM3.5
Category (site listing)Representative rating 26A (Category AC-3 AC200V) AC Operated Enclosed Type Reversible Type 2-Element Thermal Overload Relay
Получить предложение по этой позиции