MSOL-2XT50KP

Mitsubishi Electric Corporation (Factory Automation / FA Systems Group) MSOL-2XT50KP

MSOL-2xT50KP

Технические характеристики

Product SpecificationMechanically Latched Type
Напряжение питания690
AC200 to 220V11
AC380 to 440V22
AC500 to 550V22
AC220 to 240V15
AC500V25
AC690V22
Main Contact Rated Operating Current [A] > Three-Phase Squirrel-Cage Motor (Category AC-3)(Japan) > AC200 to 220V50
Main Contact Rated Operating Current [A] > Three-Phase Squirrel-Cage Motor (Category AC-3)(Japan) > AC380 to 440V48
Main Contact Rated Operating Current [A] > Three-Phase Squirrel-Cage Motor (Category AC-3)(Japan) > AC500 to 550V38
Main Contact Rated Operating Current [A] > Three-Phase Squirrel-Cage Motor (Category AC-3)(Global) > AC220 to 240V50
Main Contact Rated Operating Current [A] > Three-Phase Squirrel-Cage Motor (Category AC-3)(Global) > AC380 to 440V50
Main Contact Rated Operating Current [A] > Three-Phase Squirrel-Cage Motor (Category AC-3)(Global) > AC500V38
Main Contact Rated Operating Current [A] > Three-Phase Squirrel-Cage Motor (Category AC-3)(Global) > AC690V26
Main Contact Conventional Free Air Thermal Current [A]80
Main Contact Minimal Applicable Load48V 200mA
AC120V6
AC240V3
AC440V1.5
AC550V1.2
Auxiliary Contact Rated Operating Current [A] > AC Resistive Load (Category AC-12) > AC120V10
Auxiliary Contact Rated Operating Current [A] > AC Resistive Load (Category AC-12) > AC240V8
Auxiliary Contact Rated Operating Current [A] > AC Resistive Load (Category AC-12) > AC440V5
Auxiliary Contact Rated Operating Current [A] > AC Resistive Load (Category AC-12) > AC550V5
DC24V3
DC48V1.5
DC110V0.6
DC220V0.3
Auxiliary Contact Rated Operating Current [A] > DC Resistive Load (Category DC-12) > DC24V10
Auxiliary Contact Rated Operating Current [A] > DC Resistive Load (Category DC-12) > DC48V8
Auxiliary Contact Rated Operating Current [A] > DC Resistive Load (Category DC-12) > DC110V5
Auxiliary Contact Rated Operating Current [A] > DC Resistive Load (Category DC-12) > DC220V1
Auxiliary Contact Conventional Free Air Thermal Current [A]10
Auxiliary Contact Minimal Applicable Load20V 3mA
Main Contact (Standard)3NO×2
Auxiliary Contact (Standard)2NO2NC×2
Auxiliary Contact (Special)-
AC220V550
Main Contact Making Current Capacity [A] > Category AC-3 > AC440V500
Main Contact Making Current Capacity [A] > Category AC-3 > AC550V380
Main Contact Making Current Capacity [A] > Category AC-3 > AC690V260
Main Contact Breaking Current Capacity [A] > Category AC-3 > AC220V440
Main Contact Breaking Current Capacity [A] > Category AC-3 > AC440V400
Main Contact Breaking Current Capacity [A] > Category AC-3 > AC550V304
Main Contact Breaking Current Capacity [A] > Category AC-3 > AC690V208
Mechanical Durability [Mil.Times]25
Category AC-3 (Japan)25
Category AC-31200
Напряжение питанияAC Operated
Inrush Input [VA]Close:120(AC Operated),Trip:150(AC Operated)
Normal input [VA]-
Power Consumption [W]-
Protection Mode of Thermal Overload Relay3-element(Overlord, Constraint and Open-phase Protection)
Coil Surge Absorbing FunctionNo
Terminal CoversYes
Wiring Streamlining TerminalNo
Mounting MethodScrew Mounting, DIN Rail Mounting
Main Circuit (Power Side)M5
Main Circuit (Load Side)M5
Operating CircuitM3.5
Operation CoilM3.5
Category (site listing)Representative rating 50A (Category AC-3 AC200V) Mechanically Latched Type Reversible Type Terminal Covers 3-Element Thermal Overload Relay
Получить предложение по этой позиции