MXF100-8-N32

Mitsubishi Electric Corporation (Factory Automation / FA Systems Group) MXF100-8-N32

MXF100-8-N32

Технические характеристики

Operation control methodRepetitive operation of stored programs
I/O control modeRefresh mode (The direct access input/output is available by specifying the direct access input/output (DX, DY).)
Programming language• Ladder diagram (LD) • Structured text (ST) • Function block diagram (FBD/LD)
Extended programming language• Function block (FB) • Label programming
Program execution typeInitial, scan, fixed scan, interrupt, and standby
Number of I/O points512 points
Program memory30 MB
Program cache memory12 MB
Device/label memory8 MB
Data memory15 MB
Online changeSupported
Double-precision floating-point processing2.50 ns…
LD instruction1.25 ns…
Number of occupied I/O pointsNot supported
Number of slots occupied by a moduleNot supported
USB portUSB 2.0 High Speed (Type-C) × 1
Ethernet portOne of the CC-Link IE TSN ports can be switched to the Ethernet port.
CC-Link IE TSN port1000BASE-T/100BASE-TX × 2 One of the CC-Link IE TSN ports can be switched to the Ethernet port.
SD memory cardSD/SDHC memory card
Real drive axis8 axes
Motion operation cycle [μs]250, 500, 1000, 1500, 2000, 2500, 3000, 3500, 4000, 4500, 5000, 5500, 6000, 6500, 7000, 7500, 8000
Servo amplifier connectionMR-J5-G, MR-J5W2-G, MR-J5W3-G, MR-J5D1-G4, MR-J5D2-G4, MR-J5D3-G4, CC-Link IE TSN-compatible drive, MR-JET
Absolute position control system64 bit control/32 bit control
Positioning range64 bit floating-point (LREAL type)
Interpolation functionLinear interpolation (4 axes maximum), 2-axis circular interpolation
Control methodPTP control, speed control, speed-position switching control (future support), speed control/torque control/continuous operation to torque control, pressure control (future support), multi-axis positioning data operation, position follow-up control, and motion cyclic instruction (position, velocity, and torque)
Operation cycles mixed3 groups
System memory size96 MB
Size of built-in ROM for user data15 MB (Data memory is used.)
AxisReal drive axis, virtual drive axis, real encoder axis, virtual encoder axis, and virtual linked axis
Axes group0: Not set 1…: Setting axes group No.
Axis > Real drive axisServo amplifier
Real encoder axisVia a servo amplifier
Compensation functionDriver unit conversion function and phase compensation function (future support)
InstructionAdvanced synchronous control and cam operation start (MC_Camln)
ModuleMaster axis, cam, gear, and clutch
Master axisReal drive axis, virtual drive axis, real encoder axis, virtual encoder axis, and virtual linked axis
Start/stopStart, stop, restart, buffer mode, and forced stop
Home position return methodDriver home position return method (use the home position return method set in the driver)
Linear controlLinear interpolation (2…4 axes)
2-axis circular interpolationBorder point specification, center point specification, and radius specification
Manual controlJOG operation
Speed controlSpeed control not including position loop and speed control including position loop
Torque controlTorque control and continuous operation to torque control
Absolute positioning systemProvided (batteryless)
Velocity limitVelocity set range
Torque limitPositive direction torque limit value, negative direction torque limit value
Forced stopEnabled/disabled switching
Software stroke limitCheck the movable range at the set position and the machine feed value.
Hardware stroke limitSupported
Set velocity changeSupported
Current value changeSupported
Acceleration/deceleration process changeAcceleration/deceleration and acceleration/deceleration time
Torque limit value changeSupported
Target position changeTarget position change and movement distance change
OverrideSupported
History dataPosition data history
Axis emulationSupported
Touch probe (mark detection)Supported
Monitoring of servo dataCyclic transmission and transient transmission
Servo system recorderNot supported
Digital cam switchSupported
Number of registrations60000 maximum (settable number from engineering tool: 1024)
TypeCam data and rotary knife
Interpolation methodSpecifying for each section, linear interpolation, and spline interpolation
Profile ID1…60000
Resolution8…65535 (optional)
Unit of length per cycle settingmm, inch, pulse, degree
Unit of stroke amount%, mm, inch, pulse, degree
Cam auto-generationCam auto-generation cam for rotary knife
Transmission speed1 Gbps/100 Mbps
Maximum number of connectable stations per network39 stations (manager station: 1, device station: 38)
Network topologyLine topology, star topology, coexistence of line and star topologies
Line connection3800 m (when 39 stations are connected)
OthersDepends on the system configuration.
Maximum station-to-station distance100 m
RX/RY16K points (16384 points, 2 KB) for each
RWr/RWw8K points (8192 points, 16 KB) for each
Maximum number of link points per station > RX/RYManager station: 8K points (8192 points, 1 KB) for each
Maximum number of link points per station > RWr/RWwManager station: 4K points (4096 points, 8 KB) for each
Connection cableEthernet cable (Category 5e or higher)
Communication methodTime sharing method
Transient transmission capacityMaximum 1920 bytes
Напряжение питания24 V DC
Напряжение питания+20%, -15%
Allowable momentary power failure time5 ms or less (at 24 V)
Power fuse125 V, 3.15 A time-lag fuse
Inrush current100 A, 0.06 ms or less 4.0 A, 350 ms or less
Power consumptionController alone: 13.6 W or less Maximum configuration for connection to the controller: 32.0 W or less (external 24 V DC power supply of extension devices is not included)
24 V DC built-in power supply capacity500 mA
5 V DC built-in power supply capacity720 mA
Рабочая температура0…55°C, non-freezing
Storage ambient temperature-25…75°C, non-freezing
Operating ambient humidity5…95% RH, non-condensing *2
Storage ambient humidity5…95% RH, non-condensing
Frequency: 5…8.4 HzHalf amplitude: 1.75 mm Number of sweeps: 10 times each in X, Y, and Z directions (total 80 minutes in each direction)
Frequency: 8.4…150 HzConstant acceleration: 4.9 m/s 2 Number of sweeps: 10 times each in X, Y, and Z directions (total 80 minutes in each direction)
Shock resistance *3147 m/s 2 , Duration of action: 11 ms, 3 times each in X, Y, and Z bidirections by sine half-wave pulse
Noise immunityBy noise simulator at noise voltage of 1000 Vp-p, noise width of 1 μs and period of 30…100 Hz
GroundingGrounding resistance of 100Ω or less (Common grounding with a heavy electrical system is not allowed) *5
Operating atmosphereNo corrosive gases and flammable gases, less conductive dust
Operating altitude *60…2000 m
Installation locationInside a control panel *7
Напряжение питанияII or less
Pollution degree *92 or less
Category (site listing)Program memory: 30 MB Maximum number of controllable axes: 8 axes Built-in CC-Link IE TSN Input: 16 points Output: 16 points transistor (sink)