Технические характеристики

Operating systemVxWorks Version 5.4
Programming languageC language (C/C++)
Endian formatBig endian
Standard ROM6M bytes
Work RAM (for OS, driver, user program execution)64M bytes
Battery-backed-up RAM128K bytes
Number of channels1 channel
Interface10BASE-T, 100BASE-TX
Communication methodFull-duplex/half-duplex communication mode
Data transmission speed10 Mbps (10BASE-T), 100 Mbps (100BASE-TX)
Transmission methodBase band
Number of cascaded connectionsMaximum 4 stages (10BASE-T)/Maximum 2 stages (100BASE-TX)
Maximum segment length100 m
Connector applicable to external wiringRJ45
Supported functionAuto-negotiation function (automatic recognition of communication speed/communication method)
RS-232 > InterfaceCompliant with RS-232
RS-232 > Communication methodFull-duplex/half-duplex communications
Synchronization methodStart-stop synchronization method
Transmission speed9600, 14400, 19200, 28800, 38400, 57600, 115200 bps
Transmission distanceUp to 15 m
Start bit1
Data bit7/8
Parity bits1 (vertical parity) or none
Stop bit1/2
Parity checkYes (Even/Odd) / No
Sum check codeYes / No
Transmission controlFlow control (RS/CS control)
RS-232 > Connector applicable to external wiring9-pin D-sub (male) screw type
Number of I/O points4096 points (X/Y0...FFF)
Displayed informationYear, month, date, hour, minute, second, and day of the week (Automatic leap year detection)
Clock accuracy during power ONAccuracy of VxWorks POSIX Clock Accuracy may vary by the operation program.
Clock accuracy during power OFFDaily error: -10.89...+8.64 s (0...55 ˚C) Daily error: -4.32...+5.25 s (25 ˚C) At power ON, an additional error of -0.5...+0.5 s seconds may occur.
Allowable momentary power failure timeThe time differs depending on the power supply module used.
Internal current consumption (5 V DC)0.71 A
Height98 mm
Width27.4 mm
Depth89.3 mm
Масса0.17 kg
Рабочая температура0...55 ˚C
Storage ambient temperature-25...75 ˚C
Operating ambient humidity5...95 %RH, non-condensing
Storage ambient humidity5...95 %RH, non-condensing
Under intermittent vibrationFrequency: 5...8.4 Hz, Half amplitude: 3.5 mm Frequency: 8.4...150 Hz, Constant acceleration: 9.8 m/s 2 Sweep count: 10 times each in X, Y, Z directions
Under continuous vibrationFrequency: 5...8.4 Hz, Half amplitude: 1.75 mm Frequency: 8.4...150 Hz, Constant acceleration: 4.9 m/s 2
Shock resistanceCompliant with JIS B 3502 and IEC 61131-2 (147 m/s 2 , 3 times each in 3 directions X, Y, Z)
Operating atmosphereNo corrosive gases
Operating altitude0...2000 m
Installation locationInside a control panel
Напряжение питанияII or less
Pollution degree2 or less
Equipment classClass I
Category (site listing)C Controller CPU
Получить предложение по этой позиции