Mitsubishi Electric Corporation (Factory Automation / FA Systems Group) VS70C-600-R
VS70C-600-R
Технические характеристики
| Series | VS70 |
|---|---|
| Processor performance | 1 time |
| Memory | 7.2 GB flash memory Unlimited storage when storing in the remote network device Image processing: 512 MB SDRAM |
| Imager type | 1/1.8 inch CMOS, global shutter 4.5 x 4.5 μm square pixels |
| Imagery | Color |
| Lens | C-mount, S-mount/M12, autofocus |
| Image resolution (pixels) *1 | 640 x 480, 800 x 600 |
| Bit depth | 24-bit color |
| Electronic shutter speed *2 | 14 μs...520 ms, 14 μs...550 ms |
| Maximum image acquisition speed *3 *4 | 135 frames/sec., 100 frames/sec. |
| PatMax RedLine® | ● |
| Spreadsheet | ● |
| Power consumption | 24 V DC ± 10 %, 36 W (1.5 A) maximum |
| Power output | 24 V DC/750 mA maximum to an external light |
| Trigger | Opto-isolated image acquisition trigger input x 1, remote software commands via Ethernet |
| Discrete inputs *5 | General-purpose input x 3 (available when connected with a breakout cable) Option: General-purpose input x 8 (available when connecting a CIO-MICRO I/O module) General-purpose input x 7 (available when connecting a CIO-1400 I/O module) |
| Discrete outputs *5 | High-speed output x 4 (available when connected with a breakout cable) Option: High-speed output x 2, general-purpose output x 8 (available when connecting a CIO-MICRO I/O module) High-speed output x 2, general-purpose output x 6 (available when connecting a CIO-1400 I/O module) |
| Network communication | CC-Link IE Field Network Basic, SLMP scanners, SLMP, EtherNet/IP, MODBUS/TCP, TCP/IP, UDP, FTP, Telnet (native mode), DHCP (default at shipment from the factory), fixed and link local IP address setting |
| Материал | Die-cast and extruded aluminum housing |
| Installation | M3 screw hole x 4 |
| Dimensions | 35.7 mm × 60.5 mm × 90.0 mm |
| Масса | 240 g |
| Ambient operating temperature | 0...40°C (Case temperature: less than 50°C) |
| Ambient storage temperature | –20...80°C |
| Maximum humidity | Less than 80% RH, non-condensing |
| Vibration resistance | IEC 60068-2-6: A vibration of 10 G (10 to 500 Hz at 100 m/s 2 with 15 mm width) was applied to each X, Y, and Z direction for 2 hours |
| Shock resistance | IEC 60068-2-27: 18 half sinusoidal shocks (3 shocks for each X, Y, and Z direction) with 80 G (800 m/s 2 at 11 ms) were applied. |
| Operating atmosphere | There is no danger of corrosive gases, flammable gases, and strong alkaline substances to adhere. |
| Protective structure | IP67 (with cables connected and appropriate lens attached) |
| Category (site listing) | VS70 |