Технические характеристики

SeriesVS70
Processor performance1.25 times
Memory7.2 GB flash memory Unlimited storage when storing in the remote network device Image processing: 512 MB SDRAM
Imager type1/1.8 inch CMOS, global shutter 9 mm diagonal, 4.5 x 4.5 μm square pixels
ImageryMonochrome
LensC-mount, S-mount/M12, autofocus
Image resolution (pixels) *11600 x 1200
Bit depth256 gray levels (8 bits/pixel)
Electronic shutter speed *220 μs...940 ms
Maximum image acquisition speed *3 *453 frames/sec.
PatMax RedLine®-
Spreadsheet-
Power consumption24 V DC ± 10 %, 36 W (1.5 A) maximum
Power output24 V DC/750 mA maximum to an external light
TriggerOpto-isolated image acquisition trigger input x 1, remote software commands via Ethernet
Discrete inputs *5General-purpose input x 3 (available when connected with a breakout cable) Option: General-purpose input x 8 (available when connecting a CIO-MICRO I/O module) General-purpose input x 7 (available when connecting a CIO-1400 I/O module)
Discrete outputs *5High-speed output x 4 (available when connected with a breakout cable) Option: High-speed output x 2, general-purpose output x 8 (available when connecting a CIO-MICRO I/O module) High-speed output x 2, general-purpose output x 6 (available when connecting a CIO-1400 I/O module)
Network communicationCC-Link IE Field Network Basic, SLMP scanners, SLMP, EtherNet/IP, MODBUS/TCP, TCP/IP, UDP, FTP, Telnet (native mode), DHCP (default at shipment from the factory), fixed and link local IP address setting
МатериалDie-cast and extruded aluminum housing
InstallationM3 screw hole x 4
Dimensions35.7 mm × 60.5 mm × 90.0 mm
Масса240 g
Ambient operating temperature0...40°C (Case temperature: less than 50°C)
Ambient storage temperature–20...80°C
Maximum humidityLess than 80% RH, non-condensing
Vibration resistanceIEC 60068-2-6: A vibration of 10 G (10 to 500 Hz at 100 m/s 2 with 15 mm width) was applied to each X, Y, and Z direction for 2 hours
Shock resistanceIEC 60068-2-27: 18 half sinusoidal shocks (3 shocks for each X, Y, and Z direction) with 80 G (800 m/s 2 at 11 ms) were applied.
Operating atmosphereThere is no danger of corrosive gases, flammable gases, and strong alkaline substances to adhere.
Protective structureIP67 (with cables connected and appropriate lens attached)
Category (site listing)VS70
Получить предложение по этой позиции