Rockwell Automation, Inc. 1408-BC3A-ENT
PowerMonitor 1000, Consumption, ENet
Технические характеристики
| Build America, Buy America | No |
|---|---|
| Repair Options Available | No |
| General Features – Accuracy | Power functions : kW, kVA, kVAR: EN62053-21:2003 accuracy requirement Class 1 |
| Data Handling – Alarm log | true |
| Power / Electrical Characteristics – Ampere meter | true |
| Measurement / Parameters – Apparent power consumption (kVAh) | true |
| Measurement / Parameters – Apparent power (kVA) | true |
| Communication / Interfaces – Basic consumption meter w/ Ethernet | true |
| Power / Electrical Characteristics – Blind power meter | true |
| General Features – CIP energy object | true |
| General Features – Configurable via webpage | true |
| General Features – Configuration lock wiring terminals | Wire together to help prevent configuration changes |
| General Features – Control power and ground wiring terminals | 120…240V AC, 50…60 Hz |
| Inputoutput Specifications – Control power | 85…264V AC, 47…63 Hz 125…250V DC 4VA maximun |
| Inputoutput Specifications – Current sense inputs: I1, I2, I3 | Starting current : 5 mA |
| General Features – Current sensing wiring terminals | Nominal input current 5 A, Use current transformers (CTs) to connect to power system |
| Power / Electrical Characteristics – Description | PowerMonitor 1000 energy, demand, and PowerMonitor with serial network communication |
| Environmental Operating Conditions – Dielectric withstand | UL61010, EN61010 pollution degree 2 |
| Inputs / Outputs Io – Digital accuracy | Class1 |
| Inputs / Outputs Io – Digital output | true |
| General Features – DIN rail clips | Top and bottom clips for mounting unit on DIN rail |
| Power / Electrical Characteristics – Effective power measurement device | true |
| Data Handling – Energy log | true |
| General Features – Ethernet network port - standard RJ45 jack with status indicators | Ethernet network port hardware is included on all models. the port functions only on units ordered with or upgraded to the Ethernet network. the following protocols and functions are supported. Ethernet/IP Modbus TCP HTML webpage for configuration and data access lnk indicator solid green: IP link established OFF : no link established act indicator flashing yellow: data present on Ethernet port OFF : no data activity present |
| Power / Electrical Characteristics – Frequency meter | true |
| Environmental Operating Conditions – Humidity | 5...95% noncondensing |
| General Features – LCD | Unit configuration data display - not present on BC3 model |
| General Features – Mac ID label | aa:bb:cc:dd:ee:ff, used when assigning an IP address using DHCP, X, X, X |
| Data Handling – Minimum/maximum log | true |
| General Features – Module and network status indicators | Module indicator GREEN: normal ops Alternating RED/GREEN: performing self-test RED (solid or blinking): initial power-up or failed self-test. network indicator GREEN: Ethernet connection established Blinking GREEN: Ethernet port looking for a connection RED: duplicate IP address detected. |
| Environmental Operating Conditions – Operating temperature | -10 to 60 °C |
| Power / Electrical Characteristics – Pulse counter | true |
| Measurement / Parameters – Reactive power consumption (kVARh) | true |
| Measurement / Parameters – Reactive power (kVAR) | true |
| Measurement / Parameters – Real power consumption (kWh) | true |
| Measurement / Parameters – Real power (kW) | true |
| General Features – Serial port status indicators | Tx indicator flashes yellow when data is being transmitted Rx indicator flashes yellow when data is being received |
| General Features – Serial port - three-pin RS-485 connector | All models include RS-485 serial communication that supports the following protocols and functions. DF1 half-duplex slave, DF1 full-duplex, Modbus RTU slave, Configuration by using terminal emulation software, DH-485. |
| Environmental Operating Conditions – Shock | Operating : 30 G peak each axis |
| General Features – Status-input wiring terminals Restore factory defaults wiring terminals (BC3) | Two internally-powered inputs (TS3, EM3), S2 can be used for demand period synchronization (TS3, EM3), FD1 and FD2 can be used to restore factory default configuration (BC3). |
| Environmental Operating Conditions – Storage temperature | -40 to 85 °C |
| Environmental Operating Conditions – Terminal blocks | 0.34…2.5 mm² (22 AWG), 75 °C (167 °F) min copper wire only recommended torque 0.8 N.m (7 in-lb) |
| Data Handling – Time of use log | true |
| Measurement / Parameters – True power factor | true |
| Data Handling – Unit status log | true |
| Environmental Operating Conditions – Vibration | 2.0 G @ 10…500 Hz |
| Напряжение питания | Input current : 2 mA |
| Напряжение питания | Input impedance : 5 MΩ |
| Напряжение питания | Direct connect up to 600V AC three-phase line-to-line, Maximum nominal line-to-ground voltage 347V, Use potential transformers (PTs) for higher voltages. |
| Power / Electrical Characteristics – Voltmeter | true |