Rockwell Automation, Inc. 1426-M5E
Powermonitor 5000 Base Quality Meter
Технические характеристики
| Build America, Buy America | No |
|---|---|
| Repair Options Available | No |
| General Features – Accuracy | 0.20% |
| General Features – Alarm | true |
| General Features – Application | Power Management/Quality m |
| General Features – Communications | EtherNet/IP |
| General Features – Frequency Rating | 40-75Hz |
| General Features – Interface | Webpage |
| Напряжение питания | 600VLL AC |
| General Features – Output | 4 Digital Relays |
| Data Handling – Alarm log | true |
| Environmental Operating Conditions – Altitude | 2000 m, max |
| Power / Electrical Characteristics – Ampere meter | true |
| Measurement / Parameters – Apparent energy (kVAh) | true |
| Measurement / Parameters – Apparent power demand (kVA) | true |
| Measurement / Parameters – Apparent power (kVA) | true |
| Power / Electrical Characteristics – Blind power meter | true |
| Relays / Control Outputs – Break values | (Inductive load) 0.55A @ 125V DC, maximum |
| General Features – CIP energy object | true |
| General Features – Configurable via webpage | true |
| General Features – Configuration lock switch | When enabled, this switch helps prevent changes in configuration that can affect revenue accuracy. |
| General Features – Control power and ground wiring terminals | • 120...240V AC @ 50/60Hz, or 120...240V DC • 24V DC |
| Inputoutput Specifications – Control power | 12VA @ 24V DC |
| Inputs / Outputs Io – Control relay | ANSI C37.90 trip duty: 2005 |
| Напряжение питания | 22.8...25.2V DC @ 24V DC |
| Напряжение питания | 85...264V AC 47...63 Hz Or 106...275V DC |
| Measurement / Parameters – Crest factor | V-V, V-N, and I, per phase: Yes |
| Measurement / Parameters – Current consumption | true |
| Measurement / Parameters – Current per phase and total | true |
| Inputoutput Specifications – Current sense inputs: I1, I2, I3 | Accuracy: ±0.1% @ 25°C 50/60 Hz unity power factor |
| Inputs / Outputs Io – Current sense inputs: I1, I2, I3, I4 | Starting current : 5 mA |
| General Features – Current sensing wiring terminals | Nominal input current 5 A, Use current transformers (CTs) to connect to power system |
| Measurement / Parameters – Current unbalance | true |
| Data Handling – Data log | true |
| Measurement / Parameters – Demand, amps | true |
| General Features – Demand functions | • ANSI C12.20 -2010 class 0.2 clause 5.5.4 • EN 62053-22 -2003 class 0.2 accuracy clause 8 |
| Measurement / Parameters – Demand power factor | true |
| Dimension – Depth | 178 mm |
| Power / Electrical Characteristics – Description | PowerMonitor 5000 M5 unit with native ethernet communication network |
| General Features – Device status indicators | • Device status - OFF: No control power - Flashing GREEN/RED: Self-test - Flashing GREEN: Power monitor has not been configured - GREEN: Power monitor is running - Flashing RED: Power monitor has detected a recoverable minor fault - RED: Power monitor has detected a non-recoverable major fault |
| Environmental Operating Conditions – Dielectric withstand | UL61010, EN61010 |
| Measurement / Parameters – Displacement power factor per phase and total | true |
| Power / Electrical Characteristics – Effective power measurement device | true |
| General Features – Energy functions | • ANSI C12.20 -2010 class 0.2 clause 5.5.4 • EN 62053-22 -2003 class 0.2 accuracy clause 8 |
| Data Handling – Energy log | true |
| Communication / Interfaces – EtherNet/IP | true |
| General Features – Ethernet network port - standard RJ45 jack with status indicators | Ethernet port hardware is included on all models. These protocols and functions are supported: • EtherNet/IP™ network • HTML web page for configuration and data access Ethernet indicators • LNK indicator - Solid GREEN: IP link established - Off: No link established • ACT indicator - Flashing YELLOW: Data present on Ethernet port - Off: No data activity present |
| Data Handling – Event log | true |
| Measurement / Parameters – Frequency | Nominal: 60 Hz |
| Power / Electrical Characteristics – Frequency meter | true |
| General Features – Height | 132 mm |
| Environmental Operating Conditions – Humidity | 5...95% noncondensing |
| Relays / Control Outputs – IC rating class | UL 508, CSA 22.2 @ DC: Q300 |
| General Features – IEEE 1588 precision time protocol | true |
| Environmental Operating Conditions – Installation location | Indoor use only |
| General Features – K-factor | true |
| Inputs / Outputs Io – KYZ output | Solid-state KYZ: 80mA @ 240V AC/V DC |
| Data Handling – Load factor log | true |
| Relays / Control Outputs – Load switching | 100mA @ 5V AC, 50/60 Hz, RMS, minimum |
| Relays / Control Outputs – Make values | (Inductive load) 30A @ 120V AC, 50/60 Hz, RMS, maximum |
| General Features – Metering update rates | One update per line cycle, 1024 sAles per cycle per channel |
| Data Handling – Minimum/maximum log | true |
| Relays / Control Outputs – Motor load switching | 1/3HP @ 125V AC, 50/60 Hz, RMS, maximum |
| General Features – Network demand synchronization | true |
| General Features – Network status indicators | • Network status (Native Ethernet port) - OFF: No control power - Flashing GREEN/RED: Self-test - Flashing GREEN: No CIP connection - Solid GREEN: CIP connection established - Flashing RED: CIP connection timed out - Solid RED: Duplicate IP address detected |
| General Features – Network time synchronization | true |
| Environmental Operating Conditions – Operating temperature | -20 to 70 °C |
| General Features – Power | •Power status - OFF: no control power - GREEN: control power is present |
| General Features – Power functions | • ANSI C12.20 -2010 class 0.2 clause 5.5.4 • EN 62053-22 -2003 class 0.2 accuracy clause 8 |
| Measurement / Parameters – Projected amps demand | true |
| Measurement / Parameters – Projected kVA demand | true |
| Measurement / Parameters – Projected kVAR demand | true |
| Measurement / Parameters – Projected kW demand | true |
| Power / Electrical Characteristics – Pulse counter | true |
| General Features – Pulse (digital) output (relay and KYZ) | true |
| Measurement / Parameters – Reactive energy (kVARh) | true |
| Measurement / Parameters – Reactive power demand (kVAR) | true |
| Measurement / Parameters – Reactive power (kVAR) | true |
| Measurement / Parameters – Real energy (kWh) | true |
| Measurement / Parameters – Real power demand (kW) | true |
| Measurement / Parameters – Real power (kW) | true |
| Relays / Control Outputs – Resistive load switching | 10A @ 24V DC, maximum |
| General Features – Revenue accuracy | true |
| General Features – Sag and swell detection | true |
| General Features – Security | true |
| Data Handling – Setpoint log | true |
| General Features – Setpoint programming | true |
| Environmental Operating Conditions – Shock | 50 G, nonoperating |
| General Features – Status input, KYZ output, and control relay wiring terminals | • Four internally powered (24V DC) status inputs • Status input 2 can be used for demand period synchronization • KYZ DPDT solid-state relay for signaling use • Three DPDT control relays |
| General Features – Status inputs | true |
| Environmental Operating Conditions – Storage temperature | -40 to 85 °C |
| Measurement / Parameters – Symmetrical component analysis | true |
| Data Handling – Time of use log | true |
| General Features – Total harmonic distortion (THD) | true |
| Measurement / Parameters – True power factor per phase and total | true |
| General Features – USB device port | The USB device port is a USB mini-B receptacle that accepts standard USB mini-B plugs, for connection to a host device, such as a notebook computer. |
| General Features – USB host port | USB standard A receptacle. Not used in this model. |
| General Features – VG | Connect to power system earth ground only, This connection is a functional ground. |
| Environmental Operating Conditions – Vibration | 2 G |
| General Features – Virtual wiring correction | true |
| General Features – Virtual wiring correction indicator | Use current transformers (CTs) to connect to power system |
| Напряжение питания | true |
| Напряжение питания | Input impedance: 5M Ω minimum |
| Напряжение питания | • Direct connect to up to 690V AC 3-phase line to line • Maximum nominal line to ground voltage 690 • Use potential transformers (PTs) for higher voltages • Neutral voltage and ground voltage connections |
| Напряжение питания | true |
| Power / Electrical Characteristics – Voltmeter | true |
| General Features – Web page | true |
| General Features – Width | 185 mm |
| General Features – Wiring diagnostics | true |