1444-RELX00-04RB

Rockwell Automation, Inc. 1444-RELX00-04RB

Expansion Relay Module

Технические характеристики

Build America, Buy AmericaNo
Repair Options AvailableNo
General Features – Number Of Outlet4
General Features – Number of Relays4
Communication / Interfaces – CommunicationA digital network that is used between a main module and its expansion modules is implemented on the local bus, Communication does not link main modules
Alarms / Fault Management – Communication link timeout (fixed)100 ms
Standards / Protection – Conducted RF immunity10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
Mechanical – Conductor cross section AWG/kcmil0.08
Mechanical – Conductor cross section solid or stranded0.14
Mechanical – Conductor crosssection stranded with ferrule without plastic sleeve0.25
Mechanical – Conductor crosssection stranded with ferrule with plastic sleeve0.25
Standards / Protection – Conductor/insulation temperature rating, min85 °C
Power / Electrical Characteristics – Conductor typeCopper
Mechanical – Conductor UL/cUL AWG (screw type only)0.05 mm²
Mechanical – Conductor UL/cUL AWG (spring type only)0.08 mm²
Standards / Protection – Conformal coatingAll printed circuit boards are conformal coated in accordance with IPC-A-610C and in compliance with: IPC-CC-830 B, UL508
Power / Electrical Characteristics – Consumption1.6 W
Construction – Contact arrangementSingle pole double throw (SPDT) change-over contact
МатериалGold plated
Power / Electrical Characteristics – Current56mA @ 24V (73...48mA @ 18...32V)
Construction – DepthWithout terminal base: 154 mm
Power / Electrical Characteristics – Dissipation2.3 W
Standards / Protection – EFT/B immunity±3kV @ 5kHz on unshielded relay ports
Power / Electrical Characteristics – Electrical life cycle50000 minimum
Standards / Protection – EmissionsIEC 61000-6-4
Mechanical – Enclosure type ratingNone (open-style)
Standards / Protection – ESD immunity6 kV contact discharges, 8 kV air discharges
Construction – HeightWithout terminal base: 65 mm
Alarms / Fault Management – Host notificationLocal bus status indication
Alarms / Fault Management – IndicationUpdate status indicator
Power / Electrical Characteristics – Inductive load5A @ 250V AC
Напряжение питания250V (continuous), basic insulation type between relay ports and system, Type tested at 1500V AC @ 60s
Mechanical – Mechanical life operations10000000 minimum
Power / Electrical Characteristics – ModelExpansion device
Standards / Protection – Nonoperating temperature-40 °C
Power / Electrical Characteristics – Number of relays4
Construction – Number of status indicators6
Standards / Protection – Operating temperature-25 °C
Standards / Protection – Operating temperature (screw type only), max115 °C
Standards / Protection – Operating temperature (spring type only), max105 °C
Mechanical – Operating time, max15 ms @ rated voltage
Power / Electrical Characteristics – Permissible load, min10mA @ 5V DC
Communication / Interfaces – PowerPasses power from each main module (1444-DYN04-01RA) to its expansion modules, Power is not passed between main modules, When redundant power supplies are connected to a main module, only the voted power source is distributed to its expansion modules.
Standards / Protection – Radiated RF immunity10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 1 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
Mechanical – Rail mounting possibletrue
Power / Electrical Characteristics – Rated carry current8 A
Напряжение питания18 V
Power / Electrical Characteristics – Rated current, maxDC: 5 A
Напряжение питания250V AC
Standards / Protection – Relative humidity5...95% noncondensing
Alarms / Fault Management – Relay actionSelect fault on any of Module
Mechanical – Releasing time, max5 ms @ rated voltage
Power / Electrical Characteristics – Resistive loadDC 24V @ 5A @ 40 °C (104 °F)
Mechanical – ShockOperating: 15 G
General Features – Status indicatorPower, Relay status (4), Local bus status
Mechanical – Stripping length9 mm
Standards / Protection – Surge transient immunity±1 kV line-line (DM) and ±2 kV line-earth (CM) on unshielded relay ports
Standards / Protection – Surrounding air temperature, max70 °C
Power / Electrical Characteristics – Switching capacity, maxResistive load: 2000VA
Mechanical – Torque (screw type only)0.22 nm
Communication / Interfaces – TTL signalsDual independent TTL signals, with tachom sensor status, are passed on the local bus, There can be only one tachom expansion module on a local bus, The TTL signal can serve up to six main modules
Power / Electrical Characteristics – Type of electric connectionSpring clA connection
Mechanical – Vibration2.0 G @ 10…500 Hz
Напряжение питанияNorth American: 18...32V, max 8 A, limited voltage source
Напряжение питанияDC
МассаWithout terminal base: 0.28 kg
Construction – WidthWithout terminal base: 54 mm
Power / Electrical Characteristics – Wire typeUnshielded on relay ports
Power / Electrical Characteristics – Wiring category1 - on relay ports
Mechanical – With detachable clampstrue
Получить предложение по этой позиции