Rockwell Automation, Inc. 1444-RELX00-04RB
Expansion Relay Module
Технические характеристики
| Build America, Buy America | No |
|---|---|
| Repair Options Available | No |
| General Features – Number Of Outlet | 4 |
| General Features – Number of Relays | 4 |
| Communication / Interfaces – Communication | A digital network that is used between a main module and its expansion modules is implemented on the local bus, Communication does not link main modules |
| Alarms / Fault Management – Communication link timeout (fixed) | 100 ms |
| Standards / Protection – Conducted RF immunity | 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz |
| Mechanical – Conductor cross section AWG/kcmil | 0.08 |
| Mechanical – Conductor cross section solid or stranded | 0.14 |
| Mechanical – Conductor crosssection stranded with ferrule without plastic sleeve | 0.25 |
| Mechanical – Conductor crosssection stranded with ferrule with plastic sleeve | 0.25 |
| Standards / Protection – Conductor/insulation temperature rating, min | 85 °C |
| Power / Electrical Characteristics – Conductor type | Copper |
| Mechanical – Conductor UL/cUL AWG (screw type only) | 0.05 mm² |
| Mechanical – Conductor UL/cUL AWG (spring type only) | 0.08 mm² |
| Standards / Protection – Conformal coating | All printed circuit boards are conformal coated in accordance with IPC-A-610C and in compliance with: IPC-CC-830 B, UL508 |
| Power / Electrical Characteristics – Consumption | 1.6 W |
| Construction – Contact arrangement | Single pole double throw (SPDT) change-over contact |
| Материал | Gold plated |
| Power / Electrical Characteristics – Current | 56mA @ 24V (73...48mA @ 18...32V) |
| Construction – Depth | Without terminal base: 154 mm |
| Power / Electrical Characteristics – Dissipation | 2.3 W |
| Standards / Protection – EFT/B immunity | ±3kV @ 5kHz on unshielded relay ports |
| Power / Electrical Characteristics – Electrical life cycle | 50000 minimum |
| Standards / Protection – Emissions | IEC 61000-6-4 |
| Mechanical – Enclosure type rating | None (open-style) |
| Standards / Protection – ESD immunity | 6 kV contact discharges, 8 kV air discharges |
| Construction – Height | Without terminal base: 65 mm |
| Alarms / Fault Management – Host notification | Local bus status indication |
| Alarms / Fault Management – Indication | Update status indicator |
| Power / Electrical Characteristics – Inductive load | 5A @ 250V AC |
| Напряжение питания | 250V (continuous), basic insulation type between relay ports and system, Type tested at 1500V AC @ 60s |
| Mechanical – Mechanical life operations | 10000000 minimum |
| Power / Electrical Characteristics – Model | Expansion device |
| Standards / Protection – Nonoperating temperature | -40 °C |
| Power / Electrical Characteristics – Number of relays | 4 |
| Construction – Number of status indicators | 6 |
| Standards / Protection – Operating temperature | -25 °C |
| Standards / Protection – Operating temperature (screw type only), max | 115 °C |
| Standards / Protection – Operating temperature (spring type only), max | 105 °C |
| Mechanical – Operating time, max | 15 ms @ rated voltage |
| Power / Electrical Characteristics – Permissible load, min | 10mA @ 5V DC |
| Communication / Interfaces – Power | Passes power from each main module (1444-DYN04-01RA) to its expansion modules, Power is not passed between main modules, When redundant power supplies are connected to a main module, only the voted power source is distributed to its expansion modules. |
| Standards / Protection – Radiated RF immunity | 10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 1 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz |
| Mechanical – Rail mounting possible | true |
| Power / Electrical Characteristics – Rated carry current | 8 A |
| Напряжение питания | 18 V |
| Power / Electrical Characteristics – Rated current, max | DC: 5 A |
| Напряжение питания | 250V AC |
| Standards / Protection – Relative humidity | 5...95% noncondensing |
| Alarms / Fault Management – Relay action | Select fault on any of Module |
| Mechanical – Releasing time, max | 5 ms @ rated voltage |
| Power / Electrical Characteristics – Resistive load | DC 24V @ 5A @ 40 °C (104 °F) |
| Mechanical – Shock | Operating: 15 G |
| General Features – Status indicator | Power, Relay status (4), Local bus status |
| Mechanical – Stripping length | 9 mm |
| Standards / Protection – Surge transient immunity | ±1 kV line-line (DM) and ±2 kV line-earth (CM) on unshielded relay ports |
| Standards / Protection – Surrounding air temperature, max | 70 °C |
| Power / Electrical Characteristics – Switching capacity, max | Resistive load: 2000VA |
| Mechanical – Torque (screw type only) | 0.22 nm |
| Communication / Interfaces – TTL signals | Dual independent TTL signals, with tachom sensor status, are passed on the local bus, There can be only one tachom expansion module on a local bus, The TTL signal can serve up to six main modules |
| Power / Electrical Characteristics – Type of electric connection | Spring clA connection |
| Mechanical – Vibration | 2.0 G @ 10…500 Hz |
| Напряжение питания | North American: 18...32V, max 8 A, limited voltage source |
| Напряжение питания | DC |
| Масса | Without terminal base: 0.28 kg |
| Construction – Width | Without terminal base: 54 mm |
| Power / Electrical Characteristics – Wire type | Unshielded on relay ports |
| Power / Electrical Characteristics – Wiring category | 1 - on relay ports |
| Mechanical – With detachable clamps | true |