191E-ANEJ3-DB40C-TE

Rockwell Automation, Inc. 191E-ANEJ3-DB40C-TE

2.5-4.0 A Economy Rev Starter W/Ckt-Bkr

  • Бренд: Rockwell Automation, Inc.
  • Артикул (MPN): 191E-ANEJ3-DB40C-TE
  • Статус производства: Discontinued

Технические характеристики

Build America, Buy AmericaNo
Repair Options AvailableNo
Power / Electrical Characteristics – Circuit breaker auxiliary and trip contacts for 140MInternal 140M auxiliary contact 1 NO + 1 NC
Construction – Circuit breaker frame size140M-D8E, high break plus
Напряжение питания24V DC with electronic coil
Power / Electrical Characteristics – Contactor size100-C09
Contruction – Depth83.5 mm
Power / Electrical Characteristics – Fuse or circuit breaker per NEC, max450 A @ D-frame with 100-C/104-C contactors
Contruction – Height178 mm
Power / Electrical Characteristics – Hp ratings as a UL508/CSA motor controller in group motor installations3/4…1Hp @ 230V AC, 60 Hz (with D-frame, 100-C/104-C contactors)
Power / Electrical Characteristics – Hp ratings as a UL508/CSA self-protected Type E combination motor controller3/4…1Hp @ 230V AC, 60 Hz (with D-frame, 100-C/104-C contactors)
Power / Electrical Characteristics – Hp ratings as a UL508/CSA Type F combination motor controller3/4…1Hp @ 230V AC, 60 Hz (with D-frame, 100-C/104-C contactors)
Power / Electrical Characteristics – kW ratings as a IEC for standard motor, 1500 rpm, max3 kW @ 690V AC @ 50Hz D-frame with bulletin 100-C/104-C contactors
Power / Electrical Characteristics – Modifications, accessoriesSpacer module for UL 508 type E adder module
Power / Electrical Characteristics – Number of auxiliary contacts as normally closed contact1
Power / Electrical Characteristics – Number of auxiliary contacts as normally open contact1
Power / Electrical Characteristics – Overload release current setting2.5 A
Mechanical – Rail mounting possibletrue
Напряжение питания24 V
Power / Electrical Characteristics – Short-circuit current as a IEC (Type 1 coordination), max8kA @ 690V AC, C-frame with bulletin 100-K/104-K mini contactors
Power / Electrical Characteristics – Short-circuit current as a IEC (Type 2 coordination), max50kA @ 690V AC, D-frame with bulletin 100-C/104-C contactors
Power / Electrical Characteristics – Short-circuit current as a UL508/CSA motor controller in group motor installations (Type 1 coordination), max65kA @ 480V AC, D-frame with 100-C/104-C contactors
Power / Electrical Characteristics – Short-circuit current as a UL508/CSA motor controller in group motor installations (Type 2 coordination), max65kA @ 480V AC, D-frame with 100-C/104-C contactors
Power / Electrical Characteristics – Short-circuit current as a UL508/CSA self-protected Type E combination motor controller, max65 kA @ 480Y/277V AC, D-frame with bulletin 100-C/104-C contactors
Power / Electrical Characteristics – Short-circuit current as a UL508/CSA Type F combination motor controller (Type 1 coordination), max65 kA @ 480Y/277V AC, D-frame with bulletin 100-C/104-C contactors
Power / Electrical Characteristics – Short-circuit current as a UL508/CSA Type F combination motor controller (Type 2 coordination), max65 kA @ 480Y/277V AC, D-frame with bulletin 100-C/104-C contactors
Power / Electrical Characteristics – StyleOpen type
Power / Electrical Characteristics – Type of electrical connection for auxiliary- and control current circuitScrew connection
Power / Electrical Characteristics – Type of electrical connection of main circuitScrew connection
Power / Electrical Characteristics – Type of motor starterReversing starter
Напряжение питанияDC
Contruction – Width99 mm
Power / Electrical Characteristics – With short-circuit releasetrue