Rockwell Automation, Inc. 2080-TRIMPOT6
Micro800 6 Point Trim Pot Plug-In
Технические характеристики
| Build America, Buy America | No |
|---|---|
| Repair Options Available | No |
| General Features – I/O Status Indication | None |
| General Features – Temperature Rating | -20…65 °C (-4…149 °F) |
| Power / Electrical Characteristics – Analogue inputs configurable | false |
| Power / Electrical Characteristics – Analogue outputs configurable | false |
| Power / Electrical Characteristics – Data range | 0 to 255 |
| Standards / Protection – Emissions | CISPR 11 (IEC 61000-6-4): Class A |
| Standards / Protection – ESD immunity | IEC 61000-4-2: 6 kV contact discharges, 8 kV air discharges |
| Power / Electrical Characteristics – Input, current | false |
| Power / Electrical Characteristics – Input, resistance thermometer | false |
| Power / Electrical Characteristics – Input, resistor | false |
| Power / Electrical Characteristics – Input signal, configurable | false |
| Power / Electrical Characteristics – Input, thermocouple | false |
| Напряжение питания | false |
| Mechanical – Mounting torque | 0.2 nm |
| Standards / Protection – Nonoperating temperature | -40...85 °C (-40...185 °F), IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock) |
| Standards / Protection – North American temperature code | T4 |
| Inputs / Outputs Io – Number of inputs | 6-channel, Trimpot |
| Standards / Protection – Operating altitude | 2000 m |
| Standards / Protection – Operating temperature | -20...65 °C (-4...149 °F): IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, operating dry heat), IEC 60068-2-14 (Test Nb, operating thermal shock) |
| Power / Electrical Characteristics – Output, current | false |
| Power / Electrical Characteristics – Output signal configurable | false |
| Напряжение питания | false |
| Standards / Protection – Radiated RF immunity | IEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10V/m with 200 Hz 50% pulse 100% AM @ 900 MHz, 10V/m with 200 Hz 50% pulse 100% AM @ 1890 MHz, 10V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz, |
| Standards / Protection – Relative humidity | IEC 60068-2-30 (Test Db, unpackaged dA heat), 5...95% noncondensing |
| Power / Electrical Characteristics – Resolution of the analogue outputs | 14 bit |
| Mechanical – Shock | IEC 60068-2-27 (Test Ea, unpackaged shock): DIN rail mount: 25 g, nonoperating, Panel Mount: 35 g nonoperating |
| Power / Electrical Characteristics – SIL according to IEC 61508 | None |
| Power / Electrical Characteristics – Suitable for safety functions | false |
| Standards / Protection – Surrounding air temperature, max | 65 °C |
| Mechanical – Vibration | IEC 60068-2-6 (Test Fc, operating), 2 G @ 10...500 Hz |
| Lifecycle Assessment – Cradle To Grave | 12.1 |
| Lifecycle Assessment – Cradle To Gate | 4.4 |
| Lifecycle Assessment – Database Used | Ecoinvent 3.10 |
| Lifecycle Assessment – Impact Assessment Method | EF 3.0 (Environmental Footprint) ESPR aligned |
| Lifecycle Assessment – LCA Method | ISO 14040/44 compliant |
| Lifecycle Assessment – Use Phase Electricity | European Average Grid Mix (EU-40) |
| Substance Disclosures – Environmental Compliance | See Details | Submit Inquiry |
| Substance Disclosures – SVHC Information | View Guidance |
| Product Series | A |