SC
Schneider Electric SE JGL37250D82AB
Circuit breaker, PowerPacT J, 250A, 3 pole, 500VDC, 20kA, lugs, thermal magnetic, 80%, aux
Категории:
Технические характеристики
| Range | PowerPact |
|---|---|
| Product name | PowerPact J |
| Product or Component Type | Circuit breaker |
| Device Application | Distribution |
| Line Rated Current | 250 A |
| Number of Poles | 3P |
| Control Type | Toggle |
| Breaking capacity code | G |
| Breaking capacity | 65 kA 240 V AC 50/60 Hz UL 489 35 kA 480 V AC 50/60 Hz UL 489 18 kA 600 V AC 50/60 Hz UL 489 20 kA 250 V DC UL 489 20 kA 500 V DC UL 489 |
| Напряжение питания | 600 V AC 50/60 Hz IEC 60947-3 |
| Network Frequency | 50/60 Hz |
| [Ics] rated service breaking capacity | 65 kA 220/240 V AC 50/60 Hz IEC 60947-2 35 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 18 kA 500/525 V AC 50/60 Hz IEC 60947-2 20 kA 250 V DC IEC 60947-2 20 kA 500 V DC IEC 60947-2 |
| Напряжение питания | 8 kV IEC 60947-2 |
| Trip unit technology | Thermal-magnetic |
| Magnetic tripping current | 500…850 A |
| Continuous current rating | 80 % |
| Напряжение питания | 750 V IEC 60947-2 |
| Protection Type | Overload protection Short-circuit protection |
| Accessory / separate part type | Auxiliary switch 24 V AC/DC 2 NO + 2 NC cover frame |
| Suitability for isolation | Yes IEC 60947-2 |
| Utilisation category | Category A |
| AWG gauge | 3/0 AWG...350 kcmil aluminium/copper terminals |
| Local signalling | Switched off (OFF) 1 trip indicator green) |
| Mounting mode | Unit mount lug) |
| Mounting Support | Lug |
| Electrical connection | Lugs, line Lugs, load |
| Terminal identifier | AL250JD |
| Long time pick-up adjustment range | 0.25...1 x In |
| Tightening torque | 221.3 lbf.in (25 N.m) 0.1…0.3 in² (95…185 mm²) (3/0 AWG...350 kcmil) |
| Number of slots | 2 auxiliary switch OF plug-in) 1 alarm switch SD plug-in) 1 overcurrent trip switch SDE plug-in) 1 voltage release MN or MX plug-in) |
| Power wire stripping length | 1.0 in (25 mm) |
| Height | 7.5 in (191 mm) |
| Width | 4.09 in (104 mm) |
| Depth | 3.4 in (86 mm) |
| Масса | 5.3 lb(US) (2.4 kg) |
| Communication interface | Modbus Ethernet |
| Circuit breaker application | HACR rated |
| Quality labels | CE |
| Standards | UL CSA NEMA NOM-003-SCFI-2000 IEC 60947-2 |
| Сертификация | UL CSA NOM |
| IP degree of protection | Front cover IP40 |
| Pollution degree | 3 IEC 60947-1 |
| Ambient Air Temperature for Operation | -13…158 °F (-25…70 °C) |
| Ambient Air Temperature for Storage | -58…185 °F (-50…85 °C) |
| Operating altitude | < 6561.68 ft (2000 m) without derating 5000 m with derating |
| Category | 01115-HG,HJ,JG,JJ UNIT MT BREAKER/SWITCH |
| Discount Schedule | DE2 |
| Returnability | No |
| Country of origin | US |
| Unit Type of Package 1 | PCE |
| Nbr. of units in pkg. | 1 |
| Package 1 Height | 7.5 in (19.1 cm) |
| Package 1 Width | 4.1 in (10.5 cm) |
| Package 1 Length | 5.0 in (12.7 cm) |
| Масса | 5.00009 lb(US) (2.268 kg) |
| Warranty (in months) | 18 |