ISD400-7312

SICK AG ISD400-7312

Optical data transmission ISD400-7312

  • Бренд: SICK AG
  • Артикул (MPN): ISD400-7312
  • Серия: ISD400 Series
  • Статус производства: Active

Технические характеристики

Features (Product segment)Optical data transmission
Features (Product)ISD400
Features (Product version)ISD400 Pro
МатериалAlSi12
Степень защиты (IP)IP65
Features (Light source)Laser, red, 660 nm
Features (Power consumption)1)
Features (Ambient operating temperature)–20 °C ... +55 °C
Features (Relative humidity)90 %, Non-condensing
МассаApprox. 800 g
Напряжение питанияDC 18 V ... 30 V
Mechanics/electronics (Power consumption)≤ 3.6 W 1)
Mechanics/electronics (Transmission range)0.2 m 200 m
Mechanics/electronics (Connection type)1 x Ethernet female connector M12, 4-pin, D-coded 1 x power supply male connector M12, 4-pin, A-coded
Mechanics/electronics (Frequency)F2
Степень защиты (IP)IP65
Mechanics/electronics (Protection class)III
Performance (Transmission range)0.2 m ... 200 m
Performance (Light source)Laser, red (660 nm)
Performance (Laser class)1M (IEC 60825-1:2014, EN 60825-1:2014) 1) 2)
Performance (Typ. light spot size (distance))1.75 m (at 100 m)
Performance (Aperture angle)Sender
Interfaces (Ethernet ✔ Data transmission rate 100 Mbit/s)Ethernet
Interfaces (Ethernet)✔
Interfaces (Data transmission rate)100 Mbit/s
Interfaces (Digital input)V s : sender deactivated
Interfaces (Digital output Number 1 1) Type PNP Function Output active for LOW and HIGH level Warning messages as the laser ages, if the permissible limits of the interior device temperature are exceeded or undercut, if the optical path is interrupted, if no Ethernet cable is connected, if the receiving level is undercut, if the laser is not ready for operation, if the heating is switched on.)Digital output
Interfaces (Number)1 1)
Interfaces (Type)PNP
Interfaces (Function)Output active for LOW and HIGH level
Ambient data (Electromagnetic compatibility (EMC))EN 61000-6-2 1) EN 61000-6-4
Рабочая температура–20 °C ... +55 °C
Ambient data (Max. rel. humidity (not condensing))90 %, Non-condensing
General notes (Note)Setting up a data transmission path requires a pair of devices, where one device has frequency F1 (ISD400-7xx1) and the other device has frequency F2 (ISD400-7xx2). A wide variety of Ethernet protocols can be used in protocol-free transmission (e.g., PROFINET, PROFIsafe, EtherNet/IP, EtherCAT, TCP/IP, etc.).
Сертификация✔
Сертификация✔
Сертификация✔
Сертификация✔
Сертификация✔
Сертификация✔
Сертификация✔
Classifications (ECLASS 5.1.4)19039001
Classifications (ECLASS 6.0)19179090
Classifications (ECLASS 7.0)19179090
Classifications (ECLASS 8.0)19179090
Classifications (ECLASS 9.0)19179090
Classifications (ECLASS 10.0)19179090
Classifications (ECLASS 11.0)19179090
Classifications (ECLASS 12.0)19179090
Classifications (ECLASS 13.0)19179090
Classifications (ECLASS 14.0)19179090
Classifications (ECLASS 15.0)19179090
Classifications (ETIM 6.0)EC000515
Classifications (ETIM 7.0)EC000515
Classifications (ETIM 8.0)EC000515
Classifications (ETIM 9.0)EC000515
Classifications (ETIM 10.0)EC000515
Classifications (UNSPSC 091201.0)43222624
Classifications (UNSPSC 100501.0)43222624
Classifications (UNSPSC 111201.0)43222624
Classifications (UNSPSC 120901.0)43222624
Classifications (UNSPSC 131201.0)43222624
Classifications (UNSPSC 140801.0)43222624
Classifications (UNSPSC 151101.0)43222624
Classifications (UNSPSC 160901.0)43222624
Classifications (UNSPSC 171001.0)43222624
Classifications (UNSPSC 180801.0)43222624
Classifications (UNSPSC 190501.0)43222624
Classifications (UNSPSC 200601.0)43222624
Classifications (UNSPSC 210901.0)43222624
Classifications (UNSPSC 220601.0)43222624
Classifications (UNSPSC 230701.0)43222624
Classifications (UNSPSC 240301.0)43222624
Classifications (UNSPSC 250901.0)43222624
Classifications (UNSPSC 260801.0)43222624
Получить предложение по этой позиции