Технические характеристики

Features (Usage)Can only be used in the EFI system network, e.g., with a Flexi Soft safety controller and an additional S300 or S3000 safety laser scanner
Features (Product version)S300 Mini Remote
Features (Application)Indoor
Features (Protective field range)3 m
Features (Warning field range)8 m (at 15 % reflectivity)
Features (Distance measuring range)30 m
Features (Type of field set)Triple field sets
Features (Number of field sets)16
Features (Number of fields)48
Features (Number of monitoring cases)32
Features (Scanning angle)270°
Features (Resolution (can be configured))30 mm, 40 mm, 50 mm, 70 mm, 150 mm
Features (Angular resolution)0.5°
Время отклика80 ms 1)
Features (Protective field supplement)100 mm
Features (Number of multiple samplings)2 ... 16, configurable
Features (Delay of automatic reset)2 s ... 60 s, configurable
Safety-related parameters (Type)Type 3 (IEC 61496)
Safety-related parameters (Safety integrity level)SIL 2 (IEC 61508)
Safety-related parameters (Category)Category 3 (EN ISO 13849)
Safety-related parameters (Performance level)PL d (EN ISO 13849)
Safety-related parameters (PFH D (mean probability of a dangerous failure per hour))8.0 x 10 -8
Safety-related parameters (T M (mission time))20 years (EN ISO 13849)
Functions (Multiple sampling)✔
Functions (Monitoring case switching)✔
Functions (Static protective field switching)✔
Functions (Dynamic protective field switching)✔
Functions (Contour as a reference)✔
Functions (Measured data output)None
Functions (Safe SICK device communication via EFI)✔
Interfaces (Connection type Cable, 250 mm, with male connector M12, 7-pin)Connection type
Interfaces (Connection type)Cable, 250 mm, with male connector M12, 7-pin
Interfaces (Inputs Static control inputs with EFI 5 1) Standby 1 1))Inputs
Interfaces (Static control inputs with EFI)5 1)
Interfaces (Standby)1 1)
Interfaces (Outputs Depends on the configuration of the connected EFI device)Outputs
Interfaces (Configuration method)PC with CDS (Configuration and Diagnostic Software)
Interfaces (Configuration and diagnostics interface RS-232 Transmission rate 38.4 kBaud)Configuration and diagnostics interface
Interfaces (Configuration and diagnostics interface)RS-232
Interfaces (Transmission rate)38.4 kBaud
Interfaces (Safe SICK device communication via EFI Transmission rate ≤ 500 kBaud Length of cable ≤ 20 m 2))Safe SICK device communication via EFI
Interfaces (Length of cable)≤ 20 m 2)
Electronics (Protection class)III (EN 50178, EN 60950)
Напряжение питания24 V DC (16.8 V DC ... 30 V DC)
Electronics (Power consumption)0.22 A 1) 0.24 A 2)
Mechanics (Dimensions (W x H x D))102 mm x 116 mm x 105 mm
Масса0.8 kg, without connecting cables
МатериалAluminum die cast
Mechanics (Housing color)RAL 1021 (yellow), RAL 9005 (black)
МатериалPolycarbonate
Mechanics (Optics cover surface finish)Outside with scratch-resistant coating
Степень защиты (IP)IP65 (EN 60529)
Ambient data (Ambient operating temperature)–10 °C ... +50 °C
Ambient data (Storage temperature)–25 °C ... +50 °C
Ambient data (Vibration resistance IEC 60068-2-6, IEC 60068-2-64, IEC 60721-3-5, IEC TR 60721-4-5, IEC 61496-3 Class 5M1 (IEC 60721-3-5))Vibration resistance
Ambient data (Vibration resistance)IEC 60068-2-6, IEC 60068-2-64, IEC 60721-3-5, IEC TR 60721-4-5, IEC 61496-3
Ambient data (Class)5M1 (IEC 60721-3-5)
Ambient data (Shock resistance IEC 60068-2-27, IEC 60721-3-5, IEC TR 60721-4-5, IEC 61496-3 Class 5M1 (IEC 60721-3-5) Continuous shock 50 m/s², 11 ms 100 m/s², 16 ms)Shock resistance
Ambient data (Shock resistance)IEC 60068-2-27, IEC 60721-3-5, IEC TR 60721-4-5, IEC 61496-3
Ambient data (Continuous shock)50 m/s², 11 ms
Other information (Type of light)Pulsed laser diode
Other information (Wave length)905 nm
Other information (Detectable remission factor)1.8 % ... > 1,000 %, reflectors
Other information (Laser class)1 (21 CFR 1040.10 and 1040.11, IEC 60825-1)
Сертификация✔
Сертификация✔
Сертификация✔
Сертификация✔
Сертификация✔
Сертификация✔
Сертификация✔
Classifications (ECLASS 5.1.4)27272705
Classifications (ECLASS 6.0)27272705
Classifications (ECLASS 7.0)27272705
Classifications (ECLASS 8.0)27272705
Classifications (ECLASS 9.0)27272705
Classifications (ECLASS 10.0)27272705
Classifications (ECLASS 11.0)27272705
Classifications (ECLASS 12.0)27272705
Classifications (ECLASS 13.0)27272705
Classifications (ECLASS 14.0)27272705
Classifications (ECLASS 15.0)27272705
Classifications (ETIM 6.0)EC002550
Classifications (ETIM 7.0)EC002550
Classifications (ETIM 8.0)EC002550
Classifications (ETIM 9.0)EC002550
Classifications (ETIM 10.0)EC002550
Classifications (UNSPSC 091201.0)39121528
Classifications (UNSPSC 100501.0)39121528
Classifications (UNSPSC 111201.0)39121528
Classifications (UNSPSC 120901.0)39121528
Classifications (UNSPSC 131201.0)39121528
Classifications (UNSPSC 140801.0)39121528
Classifications (UNSPSC 151101.0)39121528
Classifications (UNSPSC 160901.0)39121528
Classifications (UNSPSC 171001.0)39121528
Classifications (UNSPSC 180801.0)39121528
Classifications (UNSPSC 190501.0)39121528
Classifications (UNSPSC 200601.0)39121528
Classifications (UNSPSC 210901.0)39121528
Classifications (UNSPSC 220601.0)39121528
Classifications (UNSPSC 230701.0)39121528
Classifications (UNSPSC 240301.0)39121528
Classifications (UNSPSC 250901.0)39121528
Classifications (UNSPSC 260801.0)39121528
Получить предложение по этой позиции