TIM361-2134101S02

SICK AG TIM361-2134101S02

LiDAR sensors TIM361-2134101S02

  • Бренд: SICK AG
  • Артикул (MPN): TIM361-2134101S02
  • Статус производства: Active

Технические характеристики

Features (Application)Outdoor, Indoor
Features (Measurement principle)HDDM +
Features (Light source)Infrared (850 nm)
Features (Laser class)1 (IEC 60825-1:2014, EN 60825-1:2014+A11:2021)
Features (Aperture angle Horizontal 270°)Aperture angle
Features (Horizontal)270°
Features (Scanning frequency)15 Hz
Features (Angular resolution Horizontal 0.33°)Angular resolution
Features (Working range)0.05 m ... 10 m
Features (Scanning range At 10% remission factor 8 m)Scanning range
Features (At 10% remission factor)8 m
Features (MTTF D)100 years
Mechanics/electronics (Connection type)1 x “Ethernet” connection, 4-pin M12 female connector 1 x connection “Power”, 12-pin, M12 male connector 1 x Micro USB female connector, type B
Напряжение питания9 V DC ... 28 V DC
Mechanics/electronics (Power consumption)Typ. 4 W, 16 W with 4 max. loaded digital outputs
Mechanics/electronics (Output current)≤ 100 mA
Mechanics/electronics (Housing color)Gray (RAL 7032)
Степень защиты (IP)IP67, applies only when the plastic cover of the “Aux interface” is closed (IEC 60529:1989+AMD1:1999+AMD2:2013)
Mechanics/electronics (Protection class)III (IEC 61140:2016-1)
Масса250 g, without connecting cables
Mechanics/electronics (Dimensions (L x W x H))60 mm x 60 mm x 86 mm
Mechanics/electronics (MTBF)> 100 years
Время отклика1 scan, typ. 67 ms 2 scans, ≤ 134 ms 1)
Performance (Detectable object shape)Almost any
Performance (Systematic error)± 60 mm 2)
Performance (Statistical error)< 20 mm 2)
Performance (Integrated application)Field evaluation
Performance (Number of field sets)16 field triples (48 fields, contour as reference; 1 triple (3 flexible fields) can be configured directly at the scanner)
Performance (Simultaneous evaluation cases)1 (3 fields) 2 (2 fields for detection and 1 field for contour as reference)
Interfaces (Ethernet ✔ , TCP/IP Function Service interface, parameterization)Ethernet
Interfaces (Ethernet)✔ , TCP/IP
Interfaces (Function)Service interface, parameterization
Interfaces (USB ✔ Remark Micro USB Function Service interface, parameterization)USB
Interfaces (USB)✔
Interfaces (Remark)Micro USB
Interfaces (Digital inputs/outputs Inputs 4 Outputs 3 (NPN, additional 1 x “Device Ready”))Digital inputs/outputs
Interfaces (Inputs)4
Interfaces (Outputs)3 (NPN, additional 1 x “Device Ready”)
Interfaces (Delay time)67 ms ... 30,000 ms (configurable)
Interfaces (Dwell time)67 ms ... 600,052 ms (configurable)
Interfaces (Optical indicators)2 LEDs (ON, switching status)
Ambient data (Remission factor)4 % ... 1,000 % (reflectors)
Ambient data (Electromagnetic compatibility (EMC) Emitted radiation Residential area (EN 61000-6-3:2007+AMD:A1:2011) Electromagnetic immunity Industrial environment (EN 61000-6-2:2005))Electromagnetic compatibility (EMC)
Ambient data (Emitted radiation)Residential area (EN 61000-6-3:2007+AMD:A1:2011)
Ambient data (Electromagnetic immunity)Industrial environment (EN 61000-6-2:2005)
Ambient data (Vibration resistance Sine resonance scan 10 Hz ... 1,000 Hz 1) Sine test 10 Hz ... 500 Hz, 5 g, 10 frequency cycles 1) Noise test 10 Hz ... 250 Hz, 4.24 g RMS, 5 h 2))Vibration resistance
Ambient data (Sine resonance scan)10 Hz ... 1,000 Hz 1)
Ambient data (Sine test)10 Hz ... 500 Hz, 5 g, 10 frequency cycles 1)
Ambient data (Noise test)10 Hz ... 250 Hz, 4.24 g RMS, 5 h 2)
Ambient data (Shock resistance)50 g, 11 ms, ± 3 single shocks/axis 3) 25 g, 6 ms, ± 1,000 continuous shocks/axis 3) 50 g, 3 ms, ± 5,000 continuous shocks/axis 3)
Ambient data (Ambient operating temperature)–25 °C ... +50 °C 4)
Ambient data (Storage temperature)–40 °C ... +75 °C 4)
Ambient data (Switch-on temperature)–10 °C ... +50 °C
Ambient data (Temperature change)–25 °C ... +50 °C, 10 cycles 5)
Ambient data (Damp heat)+25 °C ... +55 °C, 95 % RH, 6 cycles 6)
Ambient data (Relative humidity Operation < 80 %, Non-condensing (EN 60068-2-30:2005) Storage ≤ 90 %, Non-condensing (EN 60068-2-30:2005))Relative humidity
Ambient data (Operation)< 80 %, Non-condensing (EN 60068-2-30:2005)
Ambient data (Storage)≤ 90 %, Non-condensing (EN 60068-2-30:2005)
Ambient data (Ambient light immunity)80,000 lx
General notes (Note on use)The sensor does not constitute a safety component as defined by relevant legislation on machine safety.
Сертификация✔
Сертификация✔
Сертификация✔
Сертификация✔
Сертификация✔
Сертификация✔
Classifications (ECLASS 5.1.4)27270990
Classifications (ECLASS 6.0)27270913
Classifications (ECLASS 7.0)27270913
Classifications (ECLASS 8.0)27270913
Classifications (ECLASS 9.0)27270913
Classifications (ECLASS 10.0)27270913
Classifications (ECLASS 11.0)27270913
Classifications (ECLASS 12.0)27270913
Classifications (ECLASS 13.0)27270913
Classifications (ECLASS 14.0)27270913
Classifications (ECLASS 15.0)27270913
Classifications (ETIM 6.0)EC002550
Classifications (ETIM 7.0)EC002550
Classifications (ETIM 8.0)EC002550
Classifications (ETIM 9.0)EC002550
Classifications (ETIM 10.0)EC002550
Classifications (UNSPSC 091201.0)41111615
Classifications (UNSPSC 100501.0)41111615
Classifications (UNSPSC 111201.0)41111615
Classifications (UNSPSC 120901.0)41111615
Classifications (UNSPSC 131201.0)41111615
Classifications (UNSPSC 140801.0)41111615
Classifications (UNSPSC 151101.0)41111615
Classifications (UNSPSC 160901.0)41111615
Classifications (UNSPSC 171001.0)41111615
Classifications (UNSPSC 180801.0)41111615
Classifications (UNSPSC 190501.0)41111615
Classifications (UNSPSC 200601.0)41111615
Classifications (UNSPSC 210901.0)41111615
Classifications (UNSPSC 220601.0)41111615
Classifications (UNSPSC 230701.0)41111615
Classifications (UNSPSC 240301.0)41111615
Classifications (UNSPSC 250901.0)41111615
Classifications (UNSPSC 260801.0)41111615
Получить предложение по этой позиции