V3S145-1AAAADA-OD-PRIME

SICK AG V3S145-1AAAADA-OD-PRIME

Machine vision V3S145-1AAAADA OD Prime

  • Бренд: SICK AG
  • Артикул (MPN): V3S145-1AAAADA-OD-PRIME
  • Статус производства: Active

Категории:

Технические характеристики

Features (Technology)3D snapshot time-of-flight
Features (Programmable)✔
Features (Configurable)✔
Features (Pre-calibrated)✔
Features (Application software)3D Object Detection Prime , For collision avoidance for mobile platforms, including ground filter. 1)
Features (License included)3D Object Detection Prime
Features (License type)The software is provided as a device license. A license is bound to a specific hardware ID.
Features (License period)The license is issued without a time limit.
Features (Working range)≤ 9 m 2)
Features (Field of view 70° x 60°)Field of view
Features (Angular resolution)0.14° x 0.14°
Features (Illumination)Integrated
Features (Illumination color)Infrared, laser, invisible, 855 nm, ± 5 nm
Features (Laser class)1, P0 < 17 mW, t < 25 ns (IEC 60825-1:2014) 3) EN 60825-1:2014+A11:2021
Features (Task)Detecting - Standard objects Measuring - Dimension, contour and volume Localizing, navigating and guiding - Guiding Determining position - 3D position determination
Напряжение питания24 V DC 1)
Mechanics/electronics (Power consumption)Typ. 12 W, without digital I/Os < 8 W, In energy saving mode
Mechanics/electronics (Peak current)2 A
Степень защиты (IP)IP65 IP67 IP69
Mechanics/electronics (Protection class)III
Mechanics/electronics (Housing color)Blue, black
МатериалPMMA
Масса520 g
Mechanics/electronics (Dimensions (L x W x H))80 mm x 70 mm x 77 mm
Functions (Integrated application)The installed 3D Object Detection SICK SensorApp allows flexibly customizable collision avoidance including ground filter for mobile platforms. The data is processed within the device. The SICK SensorApp can be deinstalled.
Performance (Sensor properties Sensor resolution 512 px x 424 px)Sensor properties
Performance (Sensor resolution)512 px x 424 px
Performance (Processor)1.8 GHz, 4 × ARM Cortex 1)
Performance (Scan/frame rate)≤ 30 fps
Performance (Exposure time ≤ 10 ms)Exposure time
Performance (Repeatability)Approx. 0.8 mm, at 1 m working distance 2) Approx. 5 mm, at 7 m working distance 2)
Performance (Switch-on delay)Approx. 20 s From detection to the signal when the sensor is restarted
Время откликаFor 4 fields, ≤ 110 ms 3)
Performance (Camera coexistence mode)Automatic
Interfaces (Ethernet ✔ , TCP/IP, UDP/IP Remark Data is application-specific or can be defined in independently-developed applications.)Ethernet
Interfaces (Ethernet)✔ , TCP/IP, UDP/IP
Interfaces (Remark)Data is application-specific or can be defined in independently-developed applications.
Interfaces (REST API ✔ Function Communication interface, Configuration interface)REST API
Interfaces (REST API)✔
Interfaces (Function)Communication interface, Configuration interface
Interfaces (Configuration software)SICK AppManager, SICK AppStudio, Web-Interface, Telegram interface
Interfaces (Digital inputs/outputs)6 Maximum current per digital output: 100 mA. Maximum total current for all digital outputs: < 500 mA. Voltage drop at output for 100 mA: < 2 V. Short-circuit protected.
Interfaces (Optical indicators)4 status LEDs
Ambient data (Electromagnetic compatibility (EMC))IEC 61000-6-4:2018 / EN IEC 61000-6-4:2019, IEC 61000-6-2:2005 / EN 61000-6-2:2005 / IEC 61000-6-2:2016 / EN IEC 61000-6-2:2019
Ambient data (Vibration resistance)5 g, 10 Hz ... 500 Hz (IEC 60068-2-6:2008, IEC 60068-2-64:2008)
Ambient data (Shock resistance)30 g, 11 ms (IEC 60068-2-27:2008)
Ambient data (Ambient operating temperature)–10 °C ... +50 °C 1)
Ambient data (Storage temperature)–20 °C ... +80 °C
Ambient data (Camera housing temperature)–10 °C ... +65 °C, If no adequate heat dissipation (mechanical connection, ventilation etc.) is present, heat sinks (see accessories) can keep the housing temperature below the maximum of 65 °C.
Ambient data (Damp heat)+25 °C ... +55 °C, 95 % RH, (EN 60068-2-30:2005)
Ambient data (Relative humidity)≤ 95 % RH, Non-condensing
Ambient data (Ambient light immunity)≤ 50 klx 2)
General notes (Items supplied)Hardware, software, Software license (Prime)
General notes (Minimum detectable object)40 mm x 40 mm graues Objekt, bei ≥ 6 m Arbeitsabstand, bei ≥ 30 % Remissionsgrad
Licenses (License included)3D Object Detection Prime
Сертификация✔
Сертификация✔
Сертификация✔
Сертификация✔
Сертификация✔
Сертификация✔
Classifications (ECLASS 5.1.4)27310205
Classifications (ECLASS 6.0)27310205
Classifications (ECLASS 7.0)27310205
Classifications (ECLASS 8.0)27310205
Classifications (ECLASS 9.0)27310205
Classifications (ECLASS 10.0)27310205
Classifications (ECLASS 11.0)27310205
Classifications (ECLASS 12.0)27310205
Classifications (ECLASS 13.0)27310205
Classifications (ECLASS 14.0)27310205
Classifications (ECLASS 15.0)27310205
Classifications (ETIM 6.0)EC001820
Classifications (ETIM 7.0)EC001820
Classifications (ETIM 8.0)EC001820
Classifications (ETIM 9.0)EC001820
Classifications (ETIM 10.0)EC001820
Classifications (UNSPSC 091201.0)43211700
Classifications (UNSPSC 100501.0)43211700
Classifications (UNSPSC 111201.0)43211700
Classifications (UNSPSC 120901.0)43211700
Classifications (UNSPSC 131201.0)43211731
Classifications (UNSPSC 140801.0)43211731
Classifications (UNSPSC 151101.0)43211731
Classifications (UNSPSC 160901.0)43211731
Classifications (UNSPSC 171001.0)43211731
Classifications (UNSPSC 180801.0)43211731
Classifications (UNSPSC 190501.0)43211731
Classifications (UNSPSC 200601.0)43211731
Classifications (UNSPSC 210901.0)43211731
Classifications (UNSPSC 220601.0)43211731
Classifications (UNSPSC 230701.0)43211731
Classifications (UNSPSC 240301.0)43211731
Classifications (UNSPSC 250901.0)43211731
Classifications (UNSPSC 260801.0)43211731