Features (Functional principle)Through-beam photoelectric sensor
Features (Sensing range Sensing range min. 0 m Sensing range max. 60 m Maximum distance range from receiver to sender (operating reserve 1) 0 m ... 60 m Recommended distance range from receiver to sender (operating reserve 2) 0 m ... 50 m Recommended sensing range for the best performance 0 m ... 50 m)Sensing range
Features (Sensing range min.)0 m
Features (Sensing range max.)60 m
Features (Maximum distance range from receiver to sender (operating reserve 1))0 m ... 60 m
Features (Recommended distance range from receiver to sender (operating reserve 2))0 m ... 50 m
Features (Recommended sensing range for the best performance)0 m ... 50 m
Features (Emitted beam Light source PinPoint LED Type of light Visible red light Shape of light spot Point-shaped Light spot size (distance) Ø 115 mm (15 m) Maximum dispersion of the emitted beam around the standardized transmission axis (squint angle) < +/- 1.0° (at T U = +23 °C))Emitted beam
Features (Light source)PinPoint LED
Features (Type of light)Visible red light
Features (Shape of light spot)Point-shaped
Features (Light spot size (distance))Ø 115 mm (15 m)
Features (Maximum dispersion of the emitted beam around the standardized transmission axis (squint angle))< +/- 1.0° (at T U = +23 °C)
Features (Key LED figures Normative reference EN 62471:2008-09 | IEC 62471:2006, modified LED risk group marking Free group Wave length 635 nm Average service life 100,000 h at T a = +25 °C)Key LED figures
Features (Normative reference)EN 62471:2008-09 | IEC 62471:2006, modified
Features (LED risk group marking)Free group
Features (Wave length)635 nm
Features (Average service life)100,000 h at T a = +25 °C
Features (Adjustment IO-Link For configuring the sensor parameters and Smart Task functions Wire/pin For activating the test input)Adjustment
Features (IO-Link)For configuring the sensor parameters and Smart Task functions
Features (Wire/pin)For activating the test input
Features (Display LED blue BluePilot: Alignment aid LED green Operating indicator Static on: power on Flashing: IO-Link mode LED yellow Status of received light beam Static on: object not present Static off: object present Flashing: Below the 1.5 function reserve)Display
Features (LED blue)BluePilot: Alignment aid
Features (LED green)Operating indicator Static on: power on Flashing: IO-Link mode
Features (LED yellow)Status of received light beam Static on: object not present Static off: object present Flashing: Below the 1.5 function reserve
Features (Part number of individual components)WSO26P-343ZZ1A0ZZZZ2ZZZZZZZZZ1, 2093999 WEO26P-34162100A00Z2ZZZZZZZZZ1, 2094003
Safety-related parameters (MTTF D)524 years
Safety-related parameters (DC avg)0%
Safety-related parameters (T M (mission time))20 years
Communication interface (IO-Link ✔ , IO-Link V1.1 Data transmission rate COM2 (38,4 kBaud) Cycle time 2.3 ms Process data length 16 Bit Process data structure Bit 0 = switching signal Q L1 Bit 1 = switching signal Q L2 Bit 2 ... 15 = empty VendorID 26 DeviceID HEX 0x800188 DeviceID DEC 8389000 Compatible master port type A SIO mode support Yes)IO-Link
Communication interface (IO-Link)✔ , IO-Link V1.1
Communication interface (Data transmission rate)COM2 (38,4 kBaud)
Communication interface (Cycle time)2.3 ms
Communication interface (Process data length)16 Bit
Communication interface (Process data structure)Bit 0 = switching signal Q L1
Communication interface (VendorID)26
Communication interface (DeviceID HEX)0x800188
Communication interface (DeviceID DEC)8389000
Communication interface (Compatible master port type)A
Communication interface (SIO mode support)Yes
Напряжение питания10 V DC ... 30 V DC 1)
Electronics (Ripple)≤ 5 V pp
Electronics (Usage category)DC-12 (According to EN 60947-5-2) DC-13 (According to EN 60947-5-2)
Electronics (Current consumption, sender)≤ 30 mA, without load. At U B = 24 V < 50 mA
Electronics (Current consumption, receiver)≤ 30 mA, without load. At U B = 24 V < 50 mA
Electronics (Protection class)III
Напряжение питанияDigital output
Electronics (Number)2 (Complementary)
Electronics (Type)Push-pull: PNP/NPN
Electronics (Switching mode)Light/dark switching
Напряжение питанияApprox. U B -2.5 V / 0 V
Напряжение питанияApprox. U B / < 2.5 V
Electronics (Output current I max.)≤ 100 mA
Electronics (Circuit protection outputs)Reverse polarity protected
Время отклика≤ 500 µs 2)
Время отклика150 µs
Electronics (Switching frequency)1,000 Hz 3)
Electronics (Pin/Wire assignment, sender Function of pin 4/black (BK) Test at 0 V)Pin/Wire assignment, sender
Electronics (Function of pin 4/black (BK))Test at 0 V
Electronics (Pin/Wire assignment, receiver Function of pin 4/black (BK) Digital output, light switching, object present → output Q L1 LOW; IO-Link communication C 4) Function of pin 4/black (BK) – detail The pin 4 function of the sensor can be configured, Additional possible settings via IO-Link Function of pin 2/white (WH) Digital output, dark switching, object present → output Ǭ L1 HIGH Function of pin 2/white (WH) – detail The pin 2 function of the sensor can be configured, Additional possible settings via IO-Link)Pin/Wire assignment, receiver
Electronics (Function of pin 4/black (BK) – detail)The pin 4 function of the sensor can be configured, Additional possible settings via IO-Link
Electronics (Function of pin 2/white (WH))Digital output, dark switching, object present → output Ǭ L1 HIGH
Electronics (Function of pin 2/white (WH) – detail)The pin 2 function of the sensor can be configured, Additional possible settings via IO-Link
Mechanics (Housing)Rectangular
Mechanics (Dimensions (W x H x D))24.6 mm x 82.5 mm x 53.3 mm
Mechanics (Connection)Cable with plug, M12, 4-pin, 318 mm
Mechanics (Connection detail Deep-freeze property Do not bend below 0 °C Conductor size 0.14 mm² Cable diameter Ø 4.8 mm Length of cable (L) 270 mm Length of male connector 48 mm Bending radius For flexible use > 12 x cable diameter Bending cycles 1,000,000)Connection detail
Mechanics (Deep-freeze property)Do not bend below 0 °C
Mechanics (Conductor size)0.14 mm²
Mechanics (Cable diameter)Ø 4.8 mm
Mechanics (Length of cable (L))270 mm
Mechanics (Length of male connector)48 mm
Mechanics (Bending radius)For flexible use > 12 x cable diameter
Mechanics (Bending cycles)1,000,000
МатериалMaterial
Mechanics (Front screen)Plastic, PMMA
Mechanics (Cable)Plastic, PVC
Mechanics (Male connector)Plastic, VISTAL®
МассаApprox. 200 g
Mechanics (Maximum tightening torque of the fixing screws)1.3 Nm
Степень защиты (IP)IP66 (EN 60529) IP67 (EN 60529) IP69 (EN 60529) 1)
Ambient data (Ambient operating temperature)–40 °C ... +60 °C
Ambient data (Ambient temperature, storage)–40 °C ... +75 °C
Ambient data (Shock resistance)50 g, 11 ms (25 positive and 25 negative shocks per axis, for X, Y, Z axes, 150 shocks in total (EN60068-2-27)) 50 g, 6 ms (5,000 positive and 5,000 negative shocks per axis, for X, Y, Z axes, 30,000 shocks in total (EN60068-2-27))
Ambient data (Vibration resistance)10 Hz ... 2,000 Hz (Amplitude 0.5 mm / 10 g, 20 sweeps per axis, for X, Y, Z axes, 1 octave/min, (EN60068-2-6))
Ambient data (Air humidity)35 % ... 95 %, relative humidity (no condensation)
Ambient data (Electromagnetic compatibility (EMC))EN 60947-5-2
Ambient data (Resistance to cleaning agent)ECOLAB
Ambient data (UL File No.)NRKH.E181493 & NRKH7.E181493
Smart Task (Smart Task name)Base logics
Smart Task (Logic function)Direct AND OR Window Hysteresis
Smart Task (Timer function)Deactivated Switch-on delay Off delay ON and OFF delay Impulse (one shot)
Smart Task (Inverter)Yes
Smart Task (Switching frequency)SIO Logic: 800 Hz 1) IOL: 650 Hz 2)
Время откликаSIO Logic: 600 µs 1) IOL: 750 µs 2)
Smart Task (Repeatability)SIO Logic: 300 µs 1) IOL: 400 µs 2)
Smart Task (Switching signal Switching signal Q L1 Switching output)Switching signal
Smart Task (Switching signal Q L1)Switching output
Diagnosis (Device status)Yes
Diagnosis (Quality of teach)Yes
Diagnosis (Quality of run)Yes, Contamination display
Сертификация✔
Сертификация✔
Сертификация✔
Сертификация✔
Сертификация✔
Сертификация✔
Сертификация✔
Сертификация✔
Сертификация✔
Сертификация✔
Сертификация✔
Classifications (ECLASS 5.1.4)27270902
Classifications (ECLASS 6.0)27270902
Classifications (ECLASS 7.0)27270902
Classifications (ECLASS 8.0)27270902
Classifications (ECLASS 9.0)27270902
Classifications (ECLASS 10.0)27270902
Classifications (ECLASS 11.0)27270902
Classifications (ECLASS 12.0)27270902
Classifications (ECLASS 13.0)27270902
Classifications (ECLASS 14.0)27270902
Classifications (ECLASS 15.0)27270902
Classifications (ETIM 6.0)EC002717
Classifications (ETIM 7.0)EC002717
Classifications (ETIM 8.0)EC002717
Classifications (ETIM 9.0)EC002717
Classifications (ETIM 10.0)EC002717
Classifications (UNSPSC 091201.0)32151804
Classifications (UNSPSC 100501.0)32151804
Classifications (UNSPSC 111201.0)32151804
Classifications (UNSPSC 120901.0)32151804
Classifications (UNSPSC 131201.0)32151804
Classifications (UNSPSC 140801.0)32151804
Classifications (UNSPSC 151101.0)32151804
Classifications (UNSPSC 160901.0)32151804
Classifications (UNSPSC 171001.0)32151804
Classifications (UNSPSC 180801.0)32151804
Classifications (UNSPSC 190501.0)32151804
Classifications (UNSPSC 200601.0)32151804
Classifications (UNSPSC 210901.0)32151804
Classifications (UNSPSC 220601.0)32151804
Classifications (UNSPSC 230701.0)32151804
Classifications (UNSPSC 240301.0)32151804
Classifications (UNSPSC 250901.0)32151804
Classifications (UNSPSC 260801.0)32151804
Получить предложение по этой позиции