3RA2115-1BA16-2BB4-ZX95

Siemens AG 3RA2115-1BA16-2BB4-ZX95

SIRIUS 3RA2 load feeders

Технические характеристики

product brand nameSIRIUS
product designationDirect (on-line) starter
design of the productfor DIN-rail or screw mounting
product type designation3RA21
● of the supplied contactor3RT2016-1BB42
● of the supplied circuit-breakers3RV2011-1BA15
● of the supplied link module3RA1921-1DA00
General technical data – size of the circuit-breakerS00
General technical data – size of load feederS00
General technical data – ● at AC in hot operating state per pole2.7 W
General technical data – ● without load current share typical4 W
General technical data – type of calculation of power loss current-dependentquadratic
Напряжение питания690 V
Напряжение питания6 kV
General technical data – degree of protection NEMA ratingother
General technical data – shock resistance according to IEC 60068-2-276 g / 11 ms
General technical data – mechanical service life (operating cycles) of contactor typical30 000 000
General technical data – type of coordination2
General technical data – reference code according to IEC 81346-2:2019Q
Масса0.658 kg
Ambient conditions – ● during operation-20 ... +60 °C
Ambient conditions – ● during storage-50 ... +80 °C
Ambient conditions – ● during transport-50 ... +80 °C
Ambient conditions – temperature compensation-20 ... +60 °C
Ambient conditions – relative humidity during operation10 ... 95 %
Main circuit – number of poles for main current circuit3
Main circuit – design of the switching contactelectromechanical
Main circuit – adjustable current response value current of the current-dependent overload release1.4 ... 2 A
Main circuit – ● rated value690 V
Main circuit – ● at AC-3 rated value maximum690 V
Main circuit – ● at AC-3e rated value maximum690 V
Main circuit – operating frequency rated value50 ... 60 Hz
Main circuit – ● at AC-3 at 400 V rated value2 A
Main circuit – ● at AC-3e at 400 V rated value2 A
Main circuit – — at 400 V rated value750 W
Main circuit – — at 400 V rated value (2)750 W
Напряжение питанияDC
Напряжение питания24 V
Control circuit/ Control – holding power of magnet coil at DC4 W
Auxiliary circuit – product extension auxiliary switchYes
Auxiliary circuit – number of NC contacts for auxiliary contacts1
Auxiliary circuit – number of NO contacts for auxiliary contacts1
Protective and monitoring functions – trip classCLASS 10
Protective and monitoring functions – design of the overload releasethermal (bimetallic)
Protective and monitoring functions – response value current of instantaneous short-circuit trip unit26 A
UL/CSA ratings – ● at 480 V rated value2 A
UL/CSA ratings – ● at 600 V rated value2 A
UL/CSA ratings – — at 230 V rated value0.16 hp
UL/CSA ratings – — at 220/230 V rated value0.5 hp
UL/CSA ratings – — at 460/480 V rated value1 hp
UL/CSA ratings – — at 575/600 V rated value1.5 hp
Short-circuit protection – product function short circuit protectionYes
Short-circuit protection – design of the short-circuit tripmagnetic
Short-circuit protection – ● at 400 V according to IEC 60947-4-1 rated value150 000 A
Installation/ mounting/ dimensions – mounting positionvertical
Installation/ mounting/ dimensions – fastening methodscrew and snap-on mounting onto 35 mm DIN rail
Installation/ mounting/ dimensions – height167 mm
Installation/ mounting/ dimensions – width45 mm
Installation/ mounting/ dimensions – depth97 mm
Installation/ mounting/ dimensions – — forwards20 mm
Installation/ mounting/ dimensions – — backwards0 mm
Installation/ mounting/ dimensions – — upwards50 mm
Installation/ mounting/ dimensions – — at the side20 mm
Installation/ mounting/ dimensions – — downwards10 mm
Installation/ mounting/ dimensions – — forwards (2)20 mm
Installation/ mounting/ dimensions – — backwards (2)0 mm
Installation/ mounting/ dimensions – — upwards (2)50 mm
Installation/ mounting/ dimensions – — downwards (2)10 mm
Installation/ mounting/ dimensions – — at the side (2)20 mm
Connections/ Terminals – ● for main current circuitscrew-type terminals
Connections/ Terminals – ● for auxiliary and control circuitscrew-type terminals
Safety related data – product function suitable for safety functionYes
Safety related data – touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
Communication/ Protocol – ● PROFINET IO protocolNo
Communication/ Protocol – ● PROFIsafe protocolNo
Communication/ Protocol – protocol is supported AS-Interface protocolNo
Получить предложение по этой позиции