Реле управления
SI

Siemens AG 3RH2131-1SB40

Контакторное реле Siemens 3RH2131-1SB40, серия 3RH2. Подбор по артикулу, поставка под заказ: цену и срок уточняйте через запрос на поставку.

  • Бренд: Siemens AG
  • Артикул (MPN): 3RH2131-1SB40
  • Серия: 3RH2 Series
  • Статус производства: Не определён

Категории:

Технические характеристики

Data sheet designationcoupling contactor relay, 3 NO + 1 NC, 24 V DC, 0.85-1.85*Us, with integrated suppressor diode, screw terminal, frame size S00, suitable for PLC outputs, not expandable with auxiliary switch
product brand nameSIRIUS
product designationCoupling relay for switching auxiliary circuits
product type designation3RH2
General technical data / size of contactorS00
Напряжение питания6 kV
General technical data / shock resistance at rectangular impulse / at DC10 g / 5 ms, 5 g / 10 ms
General technical data / shock resistance with sine pulse / at DC15 g / 5 ms, 8 g / 10 ms
General technical data / mechanical service life (operating cycles) / of contactor typical30 000 000
General technical data / reference code according to IEC 81346-2K
General technical data / Substance Prohibitance (day/month/year)10/01/2009
Масса0.277 kg
Ambient conditions / installation altitude at height above sea level maximum2 000 m
Рабочая температура-25 ... +50 °C
Ambient conditions / ambient temperature / during storage-55 ... +80 °C
Main circuit / no-load switching frequency / at AC10 000 1/h
Main circuit / no-load switching frequency / at DC10 000 1/h
Control circuit/ Control / magnet coil at DC / full-scale value1.85
Control circuit/ Control / design of the surge suppressorsuppressor diode
Control circuit/ Control / closing power of magnet coil at DC1.6 W
Control circuit/ Control / holding power of magnet coil at DC1.6 W
Control circuit/ Control / closing delay / at DC25 ... 120 ms
Control circuit/ Control / opening delay / at DC5 ... 20 ms
Control circuit/ Control / arcing time10 ... 15 ms
Auxiliary circuit / number of NC contacts for auxiliary contacts1
Auxiliary circuit / instantaneous contact1
Auxiliary circuit / number of NO contacts for auxiliary contacts3
Auxiliary circuit / instantaneous contact #23
Auxiliary circuit / identification number and letter for switching elements31 E
Auxiliary circuit / operational current at AC-12 maximum10 A
Auxiliary circuit / operational current at AC-15 / at 230 V rated value10 A
Auxiliary circuit / operational current at AC-15 / at 400 V rated value3 A
Auxiliary circuit / operational current at AC-15 / at 500 V rated value2 A
Auxiliary circuit / operational current at AC-15 / at 690 V rated value1 A
Auxiliary circuit / operational current at 1 current path at DC-12 / at 24 V rated value10 A
Auxiliary circuit / operational current at 1 current path at DC-12 / at 60 V rated value6 A
Auxiliary circuit / operational current at 1 current path at DC-12 / at 110 V rated value3 A
Auxiliary circuit / operational current at 1 current path at DC-12 / at 220 V rated value1 A
Auxiliary circuit / operational current at 1 current path at DC-12 / at 440 V rated value0.3 A
Auxiliary circuit / operational current at 1 current path at DC-12 / at 600 V rated value0.15 A
Auxiliary circuit / operational current with 2 current paths in series at DC-12 / at 24 V rated value10 A
Auxiliary circuit / operational current with 2 current paths in series at DC-12 / at 60 V rated value10 A
Auxiliary circuit / operational current with 2 current paths in series at DC-12 / at 110 V rated value4 A
Auxiliary circuit / operational current with 2 current paths in series at DC-12 / at 220 V rated value2 A
Auxiliary circuit / operational current with 2 current paths in series at DC-12 / at 440 V rated value1.3 A
Auxiliary circuit / operational current with 2 current paths in series at DC-12 / at 600 V rated value0.65 A
Auxiliary circuit / operational current with 3 current paths in series at DC-12 / at 24 V rated value10 A
Auxiliary circuit / operational current with 3 current paths in series at DC-12 / at 60 V rated value10 A
Auxiliary circuit / operational current with 3 current paths in series at DC-12 / at 110 V rated value10 A
Auxiliary circuit / operational current with 3 current paths in series at DC-12 / at 220 V rated value3.6 A
Auxiliary circuit / operational current with 3 current paths in series at DC-12 / at 440 V rated value2.5 A
Auxiliary circuit / operational current with 3 current paths in series at DC-12 / at 600 V rated value1.8 A
Auxiliary circuit / operating frequency at DC-12 maximum1 000 1/h
Auxiliary circuit / operational current at 1 current path at DC-13 / at 24 V rated value10 A
Auxiliary circuit / operational current at 1 current path at DC-13 / at 60 V rated value2 A
Auxiliary circuit / operational current at 1 current path at DC-13 / at 110 V rated value1 A
Auxiliary circuit / operational current at 1 current path at DC-13 / at 220 V rated value0.3 A
Auxiliary circuit / operational current at 1 current path at DC-13 / at 440 V rated value0.14 A
Auxiliary circuit / operational current at 1 current path at DC-13 / at 600 V rated value0.1 A
Auxiliary circuit / operational current with 2 current paths in series at DC-13 / at 24 V rated value10 A
Auxiliary circuit / operational current with 2 current paths in series at DC-13 / at 60 V rated value3.5 A
Auxiliary circuit / operational current with 2 current paths in series at DC-13 / at 110 V rated value1.3 A
Auxiliary circuit / operational current with 2 current paths in series at DC-13 / at 220 V rated value0.9 A
Auxiliary circuit / operational current with 2 current paths in series at DC-13 / at 440 V rated value0.2 A
Auxiliary circuit / operational current with 2 current paths in series at DC-13 / at 600 V rated value0.1 A
Auxiliary circuit / operational current with 3 current paths in series at DC-13 / at 24 V rated value10 A
Auxiliary circuit / operational current with 3 current paths in series at DC-13 / at 60 V rated value4.7 A
Auxiliary circuit / operational current with 3 current paths in series at DC-13 / at 110 V rated value3 A
Auxiliary circuit / operational current with 3 current paths in series at DC-13 / at 220 V rated value1.2 A
Auxiliary circuit / operational current with 3 current paths in series at DC-13 / at 440 V rated value0.5 A
Auxiliary circuit / operational current with 3 current paths in series at DC-13 / at 600 V rated value0.26 A
Auxiliary circuit / operating frequency at DC-13 maximum1 000 1/h
Auxiliary circuit / contact reliability of auxiliary contacts1 faulty switching per 100 million (17 V, 1 mA)
UL/CSA ratings / contact rating of auxiliary contacts according to ULA600 / Q600
Installation/ mounting/ dimensions / width45 mm
Installation/ mounting/ dimensions / depth73 mm
Installation/ mounting/ dimensions / required spacing / with side-by-side mounting / forwards10 mm
Installation/ mounting/ dimensions / required spacing / with side-by-side mounting / upwards10 mm
Installation/ mounting/ dimensions / required spacing / with side-by-side mounting / downwards10 mm
Installation/ mounting/ dimensions / required spacing / with side-by-side mounting / at the side0 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts / forwards10 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts / upwards10 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts / at the side6 mm
Installation/ mounting/ dimensions / required spacing / for grounded parts / downwards10 mm
Installation/ mounting/ dimensions / required spacing / for live parts / forwards10 mm
Installation/ mounting/ dimensions / required spacing / for live parts / upwards10 mm
Installation/ mounting/ dimensions / required spacing / for live parts / downwards10 mm
Installation/ mounting/ dimensions / required spacing / for live parts / at the side6 mm
Connections/ Terminals / type of electrical connection for auxiliary and control circuitscrew-type terminals
Connections/ Terminals / type of connectable conductor cross-sections / for auxiliary contacts / solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
Connections/ Terminals / type of connectable conductor cross-sections / for auxiliary contacts / finely stranded with core end processing2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Connections/ Terminals / type of connectable conductor cross-sections / for AWG cables for auxiliary contacts2x (20 ... 16), 2x (18 ... 14), 2x 12
Safety related data / product function / positively driven operation according to IEC 60947-5-Yes
Safety related data / product function / suitable for safety functionYes
Safety related data / suitability for use safety-related switching OFFYes
Safety related data / service life maximum20 a
Safety related data / proportion of dangerous failures / with low demand rate according to SN 3192040 %
Safety related data / proportion of dangerous failures / with high demand rate according to SN 3192073 %
Сертификация1.3 kg
Сертификация132 kg
Сертификация-0.227 kg
Получить предложение по этой позиции