Siemens AG 3RH2131-2LB40
Контакторное реле Siemens 3RH2131-2LB40, серия 3RH2. Подбор по артикулу, поставка под заказ: цену и срок уточняйте через запрос на поставку.
Категории:
Технические характеристики
| Data sheet designation | coupling contactor relay, 3 NO + 1 NC, 24 V DC, 0.7-1.25*Us, with integrated varistor, spring-loaded terminal, frame size S00, suitable for PLC outputs, not expandable with auxiliary switch product brand name SIRIUS product designation Coupling relay for switching auxiliary circuits product type designation 3RH2 General technical data size of contactor S00 product extension auxiliary switch No |
|---|---|
| Напряжение питания | 6 kV |
| shock resistance at rectangular impulse / at DC | 10 g / 5 ms, 5 g / 10 ms |
| shock resistance with sine pulse / at DC | 15 g / 5 ms, 8 g / 10 ms |
| mechanical service life (operating cycles) / of contactor typical | 30 000 000 |
| reference code according to IEC 81346-2 | K |
| Substance Prohibitance (day/month/year) | 10/01/2009 |
| Масса | 0.298 kg |
| Ambient conditions / installation altitude at height above sea level maximum | 2 000 m |
| Рабочая температура | -25 ... +60 °C |
| Ambient conditions / ambient temperature / during storage | -55 ... +80 °C |
| Main circuit / no-load switching frequency / at AC | 10 000 1/h |
| Main circuit / no-load switching frequency / at DC | 10 000 1/h |
| Control circuit/ Control / magnet coil at DC / full-scale value | 1.25 |
| Control circuit/ Control / design of the surge suppressor | Varistor |
| Control circuit/ Control / closing power of magnet coil at DC | 2.8 W |
| Control circuit/ Control / holding power of magnet coil at DC | 2.8 W |
| Control circuit/ Control / closing delay / at DC | 25 ... 130 ms |
| Control circuit/ Control / opening delay / at DC | 7 ... 20 ms |
| Control circuit/ Control / arcing time | 10 ... 15 ms |
| Auxiliary circuit / number of NC contacts for auxiliary contacts | 1 |
| Auxiliary circuit / instantaneous contact | 1 |
| Auxiliary circuit / number of NO contacts for auxiliary contacts | 3 |
| Auxiliary circuit / instantaneous contact #2 | 3 |
| Auxiliary circuit / identification number and letter for switching elements | 31 E |
| Auxiliary circuit / operational current at AC-12 maximum | 10 A |
| Auxiliary circuit / operational current at AC-15 / at 230 V rated value | 10 A |
| Auxiliary circuit / operational current at AC-15 / at 400 V rated value | 3 A |
| Auxiliary circuit / operational current at AC-15 / at 500 V rated value | 2 A |
| Auxiliary circuit / operational current at AC-15 / at 690 V rated value | 1 A |
| Auxiliary circuit / operational current at 1 current path at DC-12 / at 24 V rated value | 10 A |
| Auxiliary circuit / operational current at 1 current path at DC-12 / at 60 V rated value | 6 A |
| Auxiliary circuit / operational current at 1 current path at DC-12 / at 110 V rated value | 3 A |
| Auxiliary circuit / operational current at 1 current path at DC-12 / at 220 V rated value | 1 A |
| Auxiliary circuit / operational current at 1 current path at DC-12 / at 440 V rated value | 0.3 A |
| Auxiliary circuit / operational current at 1 current path at DC-12 / at 600 V rated value | 0.15 A |
| Auxiliary circuit / operational current with 2 current paths in series at DC-12 / at 24 V rated value | 10 A |
| Auxiliary circuit / operational current with 2 current paths in series at DC-12 / at 60 V rated value | 10 A |
| Auxiliary circuit / operational current with 2 current paths in series at DC-12 / at 110 V rated value | 4 A |
| Auxiliary circuit / operational current with 2 current paths in series at DC-12 / at 220 V rated value | 2 A |
| Auxiliary circuit / operational current with 2 current paths in series at DC-12 / at 440 V rated value | 1.3 A |
| Auxiliary circuit / operational current with 2 current paths in series at DC-12 / at 600 V rated value | 0.65 A |
| Auxiliary circuit / operational current with 3 current paths in series at DC-12 / at 24 V rated value | 10 A |
| Auxiliary circuit / operational current with 3 current paths in series at DC-12 / at 60 V rated value | 10 A |
| Auxiliary circuit / operational current with 3 current paths in series at DC-12 / at 110 V rated value | 10 A |
| Auxiliary circuit / operational current with 3 current paths in series at DC-12 / at 220 V rated value | 3.6 A |
| Auxiliary circuit / operational current with 3 current paths in series at DC-12 / at 440 V rated value | 2.5 A |
| Auxiliary circuit / operational current with 3 current paths in series at DC-12 / at 600 V rated value | 1.8 A |
| Auxiliary circuit / operating frequency at DC-12 maximum | 1 000 1/h |
| Auxiliary circuit / operational current at 1 current path at DC-13 / at 24 V rated value | 10 A |
| Auxiliary circuit / operational current at 1 current path at DC-13 / at 60 V rated value | 2 A |
| Auxiliary circuit / operational current at 1 current path at DC-13 / at 110 V rated value | 1 A |
| Auxiliary circuit / operational current at 1 current path at DC-13 / at 220 V rated value | 0.3 A |
| Auxiliary circuit / operational current at 1 current path at DC-13 / at 440 V rated value | 0.14 A |
| Auxiliary circuit / operational current at 1 current path at DC-13 / at 600 V rated value | 0.1 A |
| Auxiliary circuit / operational current with 2 current paths in series at DC-13 / at 24 V rated value | 10 A |
| Auxiliary circuit / operational current with 2 current paths in series at DC-13 / at 60 V rated value | 3.5 A |
| Auxiliary circuit / operational current with 2 current paths in series at DC-13 / at 110 V rated value | 1.3 A |
| Auxiliary circuit / operational current with 2 current paths in series at DC-13 / at 220 V rated value | 0.9 A |
| Auxiliary circuit / operational current with 2 current paths in series at DC-13 / at 440 V rated value | 0.2 A |
| Auxiliary circuit / operational current with 2 current paths in series at DC-13 / at 600 V rated value | 0.1 A |
| Auxiliary circuit / operational current with 3 current paths in series at DC-13 / at 24 V rated value | 10 A |
| Auxiliary circuit / operational current with 3 current paths in series at DC-13 / at 60 V rated value | 4.7 A |
| Auxiliary circuit / operational current with 3 current paths in series at DC-13 / at 110 V rated value | 3 A |
| Auxiliary circuit / operational current with 3 current paths in series at DC-13 / at 220 V rated value | 1.2 A |
| Auxiliary circuit / operational current with 3 current paths in series at DC-13 / at 440 V rated value | 0.5 A |
| Auxiliary circuit / operational current with 3 current paths in series at DC-13 / at 600 V rated value | 0.26 A |
| Auxiliary circuit / operating frequency at DC-13 maximum | 1 000 1/h |
| Auxiliary circuit / contact reliability of auxiliary contacts | 1 faulty switching per 100 million (17 V, 1 mA) |
| UL/CSA ratings / contact rating of auxiliary contacts according to UL | A600 / Q600 |
| Installation/ mounting/ dimensions / width | 45 mm |
| Installation/ mounting/ dimensions / depth | 73 mm |
| Installation/ mounting/ dimensions / required spacing / with side-by-side mounting / forwards | 10 mm |
| Installation/ mounting/ dimensions / required spacing / with side-by-side mounting / upwards | 10 mm |
| Installation/ mounting/ dimensions / required spacing / with side-by-side mounting / downwards | 10 mm |
| Installation/ mounting/ dimensions / required spacing / with side-by-side mounting / at the side | 0 mm |
| Installation/ mounting/ dimensions / required spacing / for grounded parts / forwards | 10 mm |
| Installation/ mounting/ dimensions / required spacing / for grounded parts / upwards | 10 mm |
| Installation/ mounting/ dimensions / required spacing / for grounded parts / at the side | 6 mm |
| Installation/ mounting/ dimensions / required spacing / for grounded parts / downwards | 10 mm |
| Installation/ mounting/ dimensions / required spacing / for live parts / forwards | 10 mm |
| Installation/ mounting/ dimensions / required spacing / for live parts / upwards | 10 mm |
| Installation/ mounting/ dimensions / required spacing / for live parts / downwards | 10 mm |
| Installation/ mounting/ dimensions / required spacing / for live parts / at the side | 6 mm |
| Connections/ Terminals / type of electrical connection for auxiliary and control circuit | spring-loaded terminals |
| Connections/ Terminals / type of connectable conductor cross-sections / for auxiliary contacts / solid or stranded | 2x (0,5 ... 4 mm²) |
| Connections/ Terminals / type of connectable conductor cross-sections / for auxiliary contacts / finely stranded with core end processing | 2x (0.5 ... 2.5 mm²) |
| Connections/ Terminals / type of connectable conductor cross-sections / for auxiliary contacts / finely stranded without core end processing | 2x (0.5 ... 2.5 mm²) |
| Connections/ Terminals / type of connectable conductor cross-sections / for AWG cables for auxiliary contacts | 2x (20 ... 12) |
| Safety related data / product function / positively driven operation according to IEC 60947-5- | Yes |
| Safety related data / product function / suitable for safety function | Yes |
| Safety related data / suitability for use safety-related switching OFF | Yes |
| Safety related data / service life maximum | 20 a |
| Safety related data / proportion of dangerous failures / with low demand rate according to SN 31920 | 40 % |
| Safety related data / proportion of dangerous failures / with high demand rate according to SN 31920 | 73 % |
| Сертификация | 1.3 kg |
| Сертификация | 132 kg |
| Сертификация | -0.227 kg |